UT Acceptance Criteria Side by Side: AWS D1.1, ASME VIII, B31.3, API 1104 and API 650
There is no single set of ultrasonic acceptance criteria. AWS D1.1 rates each echo in decibels and limits length by severity class. ASME Section VIII Appendix 12 rejects cracks, lack of fusion and incomplete penetration at any length and limits other indications above the reference level by length; B31.3 para. 344.6.2 applies the same amplitude-and-length test to linear-type discontinuities. API 1104 classifies indications as linear, transverse or volumetric.
Behind those differences sit two philosophies. Workmanship criteria use echo amplitude as a gate and indication length as the measure: an indication below the reference level is not rejected on length, however long it looks (though Section VIII Appendix 12 still rejects one characterised as a crack or fusion-type flaw), and one above it is judged against a length limit that steps with thickness. Sizing-based criteria, which some codes allow when ultrasonics replaces radiography, ignore amplitude once a flaw is detected and judge its measured height and length against tables derived from fracture mechanics. They demand encoded, computer-recorded scanning and a sizing technique that has been demonstrated. The two cannot be mixed on one weld, and neither transfers from one code to another. So the first questions on any UT acceptance decision are the same: which construction code and edition, whether the examination is the code's own ultrasonic requirement or a substitute for radiography, and which acceptance route the contract invokes.
Source: AWS D1.1/D1.1M:2025 Structural Welding Code - Steel, Clause 8 ultrasonic acceptance tables (Tables 8.2 and 8.3 in the 2020 edition); ASME BPVC Section VIII Division 1 (2023 edition): UW-51(a)(4) and Mandatory Appendix 12; ASME BPVC Section VIII Division 2 para. 7.5.5 and Section V Article 4 (technique); ASME B31.3-2022 para. 344.6.2 and Appendix R, with B31 Case 181-2; API Standard 1104 (22nd edition; 49 CFR 192.7 and 195.3 incorporate the 21st) ultrasonic acceptance standards; API 650 Annex U (13th edition, March 2020; a 14th edition was published in August 2025). Confirm every value against the edition your construction code, regulation or contract invokes.
| Code | Where the UT acceptance rule sits | What decides accept or reject | Rejected at any size | Length or size limit |
|---|---|---|---|---|
| AWS D1.1/D1.1M:2025 | Clause 8 acceptance tables for statically and cyclically loaded nontubular connections (Tables 8.2 and 8.3 in the 2020 edition) | Indication rating d in dB (a minus b minus c), weld thickness and probe angle give a severity class A to D | Class A indications | Class B and C are length-limited; Class D accepted. See the D1.1 UT guide |
| ASME Section VIII Div 1, Mandatory Appendix 12 | Welds that Division 1 requires to be ultrasonically examined | Indications over 20% of the reference level investigated; others judged on amplitude above reference and length | Cracks, lack of fusion, incomplete penetration | 1/4 in. for t up to 3/4 in.; t/3 from 3/4 to 2-1/4 in.; 3/4 in. over 2-1/4 in. |
| ASME Section VIII Div 1, UW-51(a)(4) | UT in place of radiography where the thinner member is 1/4 in. (6 mm) or more | The ultrasonic method UW-51(a)(4) specifies, drawing on Division 2 para. 7.5.5 | As set by the referenced rules | Flaw-sizing route; Appendix 12 is not the standard here |
| ASME B31.3-2022, para. 344.6.2 | Ultrasonic examination of welds required by or substituted under the code | Linear-type discontinuity with amplitude above the reference level, judged by length | Written around linear-type discontinuities; check the edition and engineering design for a characterisation rule | 6 mm (1/4 in.) for Tw to 19 mm (3/4 in.); Tw/3 to 57 mm (2-1/4 in.); 19 mm (3/4 in.) above |
| ASME B31.3, Appendix R | Alternative ultrasonic acceptance criteria where the owner specifies them | Flaw height and length measured with computer-based, recorded scanning | Per the flaw tables | Under B31 Case 181-2: welds 25 mm (1.0 in.) and thicker; length never over 4t |
| API 1104 | Its ultrasonic acceptance subsection | Classification as linear surface, linear buried, transverse or volumetric, evaluated at the procedure's evaluation level | Cracks | Individual or aggregate lengths in any continuous 12 in. (300 mm) of weld, and a share of total weld length |
| API 650, Annex U | UT used in place of the radiography Section 8 calls for, with the Purchaser's approval | Annex U's own technique, personnel and acceptance requirements | Per Annex U | Read Annex U in the edition the tank is built to |
Why ultrasonic acceptance is written so differently from code to code
A radiograph is a picture that a second interpreter can read again years later. A manual ultrasonic examination is a set of decisions made by one technician with a probe in hand, and what reaches the report is a handful of numbers: an amplitude, a sound path, a length, perhaps a depth. Each code committee had to decide which of those numbers it trusted enough to accept or reject a weld on, and they did not all decide the same way.
The structural code chose amplitude. AWS D1.1 turns the echo into a decibel rating and reads that rating against weld thickness and probe angle. The ASME vessel rules chose a hybrid: amplitude decides whether an indication is evaluated against a length limit, but a technician who characterises an indication as a crack, lack of fusion or incomplete penetration rejects it whatever its length or amplitude. B31.3 uses the same amplitude gate and length steps for linear-type discontinuities. The pipeline standard chose classification by geometry and surface connection, then length. And where ultrasonics substitutes for radiography, the newer rules moved away from amplitude altogether, towards measured flaw height.
None of these approaches is wrong. Each fits the loading, the typical flaw population and the history of the structures it governs. What causes trouble is borrowing: a D1.1 decibel table applied to a vessel seam, or an Appendix 12 length limit applied to a girth weld. The hub guide to NDT acceptance criteria by code sets out which code governs which asset; this page compares how the codes treat the ultrasonic indication itself.
AWS D1.1: a decibel rating and four severity classes
Under D1.1 the technician peaks the indication, records the gain needed to bring it to reference height (the indication level, a), subtracts the reference level set on the calibration block (b) and an attenuation factor derived from sound path (c). The result, the indication rating d, is entered, together with weld thickness and probe angle, in the acceptance table for statically or cyclically loaded nontubular connections (Tables 8.2 and 8.3 in the 2020 edition; confirm the numbering in the 2025 edition). The table returns a severity class. Class A is rejected at any length, Class D is accepted, and Classes B and C are accepted only up to stated lengths, which tighten for cyclically loaded work.
Two consequences matter when comparing D1.1 with the pressure codes. First, the severity class comes from the rating, the thickness and the probe angle; the tables themselves do not ask the technician to name the reflector, which is where the ASME and B31.3 rules start. Second, the same indication can be acceptable statically and rejectable cyclically, so the loading condition has to be on the procedure and the report. The ultrasonic clause is also scoped: it governs groove welds within a stated thickness range and is not used for tubular T-, Y- and K-connections, which carry separate criteria. The arithmetic, the scanning levels and the common errors are worked through in our AWS D1.1 UT acceptance criteria guide; the visual and radiographic side of D1.1 has its own guide on this site.
ASME Section VIII Division 1: Appendix 12 and the ultrasonic route in place of radiography
Mandatory Appendix 12 applies where Division 1 itself calls for ultrasonic examination of a weld. The technique comes from Section V Article 4; the appendix supplies personnel, acceptance and reporting rules. Imperfections producing a response greater than 20% of the reference level are investigated until the examiner can determine their shape, identity and location. Indications characterised as cracks, lack of fusion or incomplete penetration are unacceptable regardless of length. Other imperfections are unacceptable only when their amplitude exceeds the reference level and their length exceeds 1/4 in. for t up to 3/4 in., t/3 for t from 3/4 in. to 2-1/4 in., or 3/4 in. for t over 2-1/4 in. The manufacturer keeps a report that records repaired areas and reflections above 50% of the reference level.
A different paragraph governs ultrasonic examination used instead of radiography. UW-51(a)(4) allows welds in which the thinner member joined is 1/4 in. (6 mm) or thicker to be examined ultrasonically as an alternative to the radiography otherwise required, using the method it specifies, which draws on the Division 2 ultrasonic rules in para. 7.5.5 and the Section V Article 4 appendices for encoded examination and flaw sizing. That route judges flaws by measured dimensions, not by the Appendix 12 length table, and it took over the role that Code Case 2235 used to play for Division 1 vessels. Section I boilers have their own rules on when ultrasonics may replace radiography, covered in our Section I acceptance guide.
In practice the distinction decides the procedure. An Appendix 12 examination can be performed manually with amplitude recording; a UW-51(a)(4) substitution needs a qualified encoded technique, a scan plan demonstrating coverage and a sizing method the procedure has demonstrated. Our Section VIII Division 1 acceptance criteria guide places both alongside the radiographic and surface rules for the same vessel, and Section V Article 4 covers the technique requirements.
ASME B31.3: para. 344.6.2 and the Appendix R alternative
For process piping, para. 344.6.2 is where the ultrasonic acceptance criteria live, separate from Table 341.3.2, which covers visual and radiographic examination. The length steps mirror Appendix 12, but the paragraph is framed around linear-type discontinuities rather than named flaw types: one is unacceptable when its amplitude exceeds the reference level and its length exceeds 6 mm (1/4 in.) for Tw up to 19 mm (3/4 in.), Tw/3 for Tw over 19 mm up to 57 mm (2-1/4 in.), or 19 mm (3/4 in.) for Tw over 57 mm. Where two members of different thickness are joined, Tw is the thinner one. Some owner and federal project specifications for B31.3 piping add the Appendix 12 rule that indications interpreted as cracks, lack of fusion or incomplete penetration are rejected regardless of length; where the engineering design adds it, that stricter rule governs.
B31.3 also offers a sizing-based alternative. Appendix R, titled Use of Alternative Ultrasonic Acceptance Criteria in the 2022 edition, offers the same kind of alternative that B31 Case 181-2, approved January 4, 2012, provided before it. The Case applied only where the owner specified it and only to welds 25 mm (1.0 in.) thick or more, with para. 344.6.2 governing thinner walls. It required automated or semi-automated scanning with computer-based data acquisition, data recorded in unprocessed form with no thresholding, flaws sized by the rectangle enclosing them and judged against separate surface-flaw and subsurface-flaw tables of height-to-thickness ratio, and a flaw length never exceeding 4t whatever the height. Read Appendix R itself in the edition the piping is built to before applying any of it.
Examination extent is a separate question from acceptance. Whether a girth weld receives ultrasonic examination at all, and how many welds are sampled, comes from the fluid service and the engineering design; the B31.3 acceptance criteria guide covers extent, progressive examination and the visual and radiographic limits.
API 1104 and API 650: two API documents, two different approaches
API 1104 does not reuse its radiographic categories for ultrasonics. Relevant indications above the evaluation level set in its ultrasonic test method section are classified by geometry: linear indications running along the weld, transverse indications across it, and volumetric indications with three-dimensional extent, with linear indications further split by whether they break the inside or outside surface. Indications determined to be cracks are defects. The others are judged by individual and aggregate length in any continuous 12 in. (300 mm) of weld and by share of total weld length, with buried linear indications allowed more length than surface-connected ones. Geometric responses from alignment offset, reinforcement profile, internal chamfering or mode conversion are not relevant to acceptance. Our API 1104 weld acceptance criteria guide gives the limits; check them against the edition the operator or 49 CFR invokes, because the regulation lags the latest edition.
API 650 governs new atmospheric storage tanks. Its Section 8 calls for radiography of shell butt welds, judged to Section VIII Division 1 UW-51(b), and Annex U provides the route for using ultrasonic examination in place of that radiography when the Purchaser approves it. Annex U brings its own technique, personnel and acceptance requirements rather than translating the radiographic standard, so a tank UT procedure cannot be assembled by pairing a Section V Article 4 technique with the radiographic acceptance clause. The API 650 weld acceptance criteria guide covers what Section 8 examines and where.
Amplitude, length and height: what is actually measured
Amplitude criteria are only as good as the reference they compare against. In ASME work the reference level comes from the calibration reflector the procedure specifies under Article 4, usually drawn as a distance-amplitude correction curve; in D1.1 it is the reference level set on the calibration block before each weld. An indication reported as 80% of reference is meaningless unless the report states the reflector, the block, the scanning sensitivity and whether transfer correction was applied. The distance-amplitude correction glossary entry explains how the curve is built.
Length is measured by moving the probe along the indication until the signal drops by the amount the procedure states, and the procedure, not the technician, should fix that drop and the level it is measured to. Two technicians using different conventions on the same weld will report different lengths, and on a length-limited criterion that alone can flip the decision. D1.1 defines its own length procedure; ASME and B31.3 work leaves it to the qualified procedure.
Height belongs to the sizing-based routes. It is measured by tip diffraction, time-of-flight diffraction or calibrated phased array techniques whose accuracy has been demonstrated on flaws of known size. Without that demonstration, a height figure on a report is an estimate, and a fracture-mechanics table applied to an estimate gives a false sense of precision.
Mistakes Level IIIs find in contractor UT procedures and reports
The most frequent is citing Section V Article 4 as the acceptance standard. Article 4 sets the technique; the acceptance clause has to name the construction code, the edition and the paragraph, such as Appendix 12-3 or 344.6.2. Close behind is applying the wrong code's limits: a D1.1 decibel table on a B31.3 spool, or Appendix 12 lengths on an API 1104 girth weld, often because the contractor runs one generic procedure across every job.
Other recurring faults: treating a UW-51(a)(4) or Appendix R examination as manual amplitude work with no encoded data; reporting indications below the recording level as if they were evaluated; failing to characterise an indication before applying a length limit, so a lack-of-fusion indication is accepted as short slag; using material thickness instead of sound path in D1.1 attenuation; measuring length to a different amplitude drop from the one the procedure states; and recording no scan coverage limitations where geometry blocked part of the volume. Each of these is a procedure or training problem before it is an interpretation problem, which is why a Level III review of the written procedure usually prevents more rejected reports than a review of the reports themselves.
What an ultrasonic examination report must state
For acceptance to be traceable, the report should carry: the construction code, edition and acceptance paragraph or table; the procedure number and revision; instrument, search units, angles, frequency and couplant; the calibration block and reference reflector, the reference level and the scanning sensitivity; the weld identity, thickness and joint configuration; the scanned volume, scan directions and any areas that could not be covered; and the examiner's name, level and certification under the employer's written practice.
For each relevant indication it should record a location from a stated datum, depth, length, amplitude in decibels or percentage of reference, the characterisation where the code requires one, height where the acceptance route is sizing-based, and the accept or reject decision with the clause applied. Recording acceptable indications as well as rejected ones lets a later examination tell an old indication from a new one. Report templates that build the acceptance clause into the form, such as NDT reports in Atlantis ERP, stop the clause being left blank on site.
Where Atlantis fits
Our ASNT NDT Level III writes ultrasonic procedures whose acceptance clauses cite the governing code, edition and paragraph, qualifies and demonstrates techniques before production use, and reviews contractor UT reports and data against the criteria the contract invokes. See NDT procedure development and procedure qualification and demonstration.
In the United States our technicians perform ultrasonic weld inspection, thickness work and other ultrasonic testing at the client's site, to the client's code and procedure. Technicians building the skills these criteria assume can take ultrasonic testing training built on SNT-TC-1A and practise on the Practical NDT simulator.
What are the ultrasonic acceptance criteria in ASME Section VIII Division 1?
Where Division 1 requires ultrasonic examination, Mandatory Appendix 12 applies. Responses above 20% of the reference level are investigated. Cracks, lack of fusion and incomplete penetration are rejected at any length. Other indications are rejected when amplitude exceeds the reference level and length exceeds 1/4 in. for t up to 3/4 in., t/3 up to 2-1/4 in., or 3/4 in. above. Ultrasonic examination used instead of radiography follows UW-51(a)(4) instead.
Does AWS D1.1 use distance-amplitude correction for UT acceptance?
Not in its standard clause. D1.1 compares each indication with a reference level set on the calibration block, corrects for sound path with an attenuation factor and expresses the result as a decibel rating. That rating, the weld thickness and the probe angle give a severity class from the Clause 8 acceptance table for static or cyclic loading, and the class and length decide acceptance.
What are the ASME B31.3 ultrasonic acceptance criteria?
Para. 344.6.2. A linear-type discontinuity is unacceptable when its amplitude exceeds the reference level and its length exceeds 6 mm (1/4 in.) for Tw up to 19 mm, Tw/3 up to 57 mm, or 19 mm (3/4 in.) above that. Where the engineering design adds the Appendix 12-style rule rejecting cracks, lack of fusion and incomplete penetration at any length, that stricter rule applies. Appendix R offers sizing-based alternative criteria where the owner specifies them.
Can ultrasonic testing replace radiography on a Section VIII Division 1 vessel?
Yes, under UW-51(a)(4), for welds where the thinner member is 1/4 in. (6 mm) or thicker. The substitution uses the ultrasonic method that paragraph specifies, which relies on encoded examination and flaw sizing, rather than Appendix 12. The procedure has to be qualified and the data recorded, and the Authorized Inspector will expect both.
Are cracks acceptable under any ultrasonic workmanship criteria?
No. ASME Section VIII Appendix 12 rejects indications characterised as cracks regardless of length, B31.3 rejects cracks in every column of Table 341.3.2, and API 1104 treats indications determined to be cracks as defects. Sizing-based alternatives evaluate a flaw by its measured height and length rather than its label, which is one reason they demand a demonstrated sizing technique.
What should a UT report include for code acceptance?
The construction code, edition and acceptance paragraph; procedure and revision; equipment, probes and calibration reference; reference level and scanning sensitivity; weld identity, thickness and scanned volume with any coverage limits; and, for each relevant indication, location, depth, length, amplitude, characterisation or height as the code requires, and the decision. The examiner's level and certification complete it.