Tank Inspection Services in Seattle 2026 — ASNT Level III Led
Atlantis NDT delivers tank inspection services in Seattle. Methods: UT (including PAUT and TOFD), MT, PT and VT, with procedures and reports reviewed by an ASNT NDT Level III. Seattle facilities in the aerospace, refining & maritime sectors require rigorous tank inspection services. Technicians are certified by their employer to its SNT-TC-1A written practice. Where we work: nationwide. Technicians are mobilised to your site anywhere in the USA; apart from the Houston office there is no local office, so mobilisation is planned and quoted for each job.
In the United States, Atlantis does not perform radiographic testing (RT): industrial radiography is licensed under NRC rules (10 CFR Part 34) or Agreement State rules. Where the code and the owner allow, ultrasonic testing is the volumetric alternative, and an ASNT Level III can review the radiographs and RT procedures of your licensed radiography contractor.
Tank Inspection Services Scope
Tank inspection covers: floor plates and bottom annulus via MFL; shell courses via UT thickness survey; roof, nozzles, and foundation via visual and settlement measurement — all per API 653, with API 650 new-construction alignment and EEMUA 159 guidance where applicable. Atlantis NDT Level III approves every Procedure + signs off final disposition + audit-ready records via Atlantis NDT ERP.
Code + Compliance
Tank Inspection Services per: ASME B&PV Sections V + VIII + IX + XI; ASME B31 piping series; API 510 + 570 + 571 + 579 + 580 + 581 + 653 + 1104 + 1169; ASTM E-series; ISO 17635/17636/17640; AWS D1.1/3.6; IACS Rec-20 marine; NACE MR0175 + MR0103 sour-service.
Free Consultation
Atlantis NDT publishes no pricing — varies by region + scope. Request your free 30-minute consultation. Every job is quoted on request. See also verticals, Seattle ERP, Seattle training, Seattle consulting.
What tank inspection involves
Aboveground storage tank inspection covers the shell, floor, roof and appurtenances, establishing minimum thickness by course, floor condition, settlement, and the resulting inspection intervals under API 653.
Scope of work
- External inspection of shell, roof, appurtenances, foundation and containment
- Ultrasonic shell thickness by course with minimum-required-thickness calculation
- Floor scanning by magnetic flux leakage with ultrasonic prove-up of indications
- Settlement survey and evaluation against API 653 Annex B criteria
- Vacuum box testing of floor welds and, where required, hydrostatic testing after repair
Governing codes
API 653 for inspection, repair, alteration and reconstruction, API 650 as the construction code, API 575 for practice, and API 579 where fitness-for-service assessment is required.
The Seattle asset base
Seattle is the headquarters of Boeing Commercial Airplanes (Everett 737/747/767/777/787 fabrication), Phillips 66 Ferndale Refinery (105,000 bpd), Andeavor/Marathon Anacortes Refinery (120,000 bpd), and BP Cherry Point Refinery (236,000 bpd) at the strategic Strait of Juan de Fuca corridor. Trans Mountain Pipeline's Westridge marine terminal and the Olympic Pipeline product distribution network drive PHMSA integrity-management work.
How the work is controlled
Agree personnel qualification, equipment checks, procedure revision and review responsibilities for the examination. Retain those records with the results and coverage limitations.
What you receive
- A report in your required format, with findings located against the component and, where relevant, against a persistent corrosion monitoring location so trends stay continuous between campaigns
- Raw data in the instrument-native format plus an open export, so the dataset outlives any single supplier relationship
- The procedure revision, technician certification state and instrument calibration status applicable at the time of examination
- Where a finding affects continued service, the specific code clause governing the acceptance decision
Related: asset integrity management software · inspection management software · ASNT Level III consulting · digital twin for asset integrity. Request a quote for Seattle.
Part of NDT inspection services in Washington and the full range of NDT inspection services from Atlantis NDT.
Cargo tanks, ASME pressure tanks and API 653 storage tanks in Washington: who inspects which
"Tank inspection" in Washington covers three different rule sets, and the searches that reach this page show all three: DOT certified tank repair, ASME tank inspection in Spokane and API 653 storage tanks at terminals. Each has its own legally responsible inspector. Atlantis supplies conventional NDT, meaning ultrasonic thickness, magnetic particle, liquid penetrant and visual testing, under that inspector's direction. Atlantis is not a cargo tank repair facility, not a commissioned boiler and pressure vessel inspector and not an API 653 inspector.
DOT cargo tanks: registered facilities and qualified inspectors
Tank trucks and trailers built to DOT specifications are tested on the schedule in 49 CFR 180.407: external and internal visual inspection, lining checks, pressure and leakage tests, and thickness testing. Unlined tanks carrying lading corrosive to the tank must be thickness tested at least every two years, with a device accurate to plus or minus 0.002 inch. Whoever performs or witnesses those tests must meet the qualifications in 49 CFR 180.409. Repairs go to a facility holding a National Board "R" Certificate of Authorization for ASME-stamped tanks, or to an ASME "U" or National Board "R" holder for non-ASME tanks, and every facility doing that work must be registered under 49 CFR Part 107, Subpart F. So "DOT certified tank repair" means a registered repair shop. Atlantis can examine a repair weld by MT or PT, or take UT thickness readings, when that facility's qualified inspector asks for the data; the facility certifies the tank.
"ASME tank inspection" in Spokane and across the state
An "ASME tank" is usually a pressure vessel built and stamped to ASME Section VIII, such as an air receiver or a process vessel. In Washington those fall under the Department of Labor and Industries boiler and pressure vessel program, and certificate inspections are made by L&I inspectors or by insurers' inspectors holding a Washington commission. When that inspector wants remaining wall on a shell or head, or a crack check at a nozzle weld, Atlantis can take UT readings and run MT or PT. See ultrasonic testing in Spokane and magnetic particle testing in Spokane.
Terminal and plant storage tanks under API 653
For oil terminals and refineries, Washington adds a state layer on top of federal spill rules. The Department of Ecology's facility rule, WAC 173-180-330, requires tanks at regulated oil-handling facilities to be maintained, repaired and inspected under API 653 unless Ecology approves an equivalent strategy, and to be inspected under the standard's seismic provisions; the results feed the facility's spill risk analysis. In the Puget Sound earthquake setting, good shell and foundation data matter more than usual. Conventional NDT supplies much of it:
- UT shell thickness by course and at nozzle necks, for the API 653 inspector's minimum thickness and remaining life calculation
- MT or PT on the shell-to-bottom weld, repair welds and new nozzle reinforcing pads
- Vacuum box leak testing of floor and repair welds
- Visual records of roof, seals, wind girders, anchor bolts and foundation
Floor plate coverage beyond spot UT readings needs a floor-scanning method that the API 653 inspector specifies.
How Seattle-area providers compare
Mistras lists two western Washington branches, in Kent and in Burlington near the Skagit County refineries, and its Kent page names API 653, 570 and 510 inspection among its services. Registered cargo tank shops handle DOT tests themselves. Independent API 653 inspectors and integrity firms sign tank reports and often subcontract the NDT. Ask any provider:
- Who is the legally responsible inspector for this tank, and will that person accept this company's data?
- Are UT readings recorded by course, plate and orientation so they can be repeated next interval?
- Which written practice certifies the technicians, and which ASNT Level III approved the MT, PT and UT procedures?
- When will the report be issued? Agree it before mobilization.
Atlantis on Washington tank work
Atlantis is based in Houston. Technicians travel to Seattle, Tacoma, the Skagit and Whatcom refinery sites or Spokane for the agreed scope, and every MT, PT and UT procedure is approved by an ASNT NDT Level III, who also reviews the finished report. Related pages: ultrasonic testing in Seattle, penetrant testing in Seattle, API 653 NDE support in Washington and NDT inspection services in Washington. Start with the Washington tank enquiry; we reply within one business day.