Ultrasonic Testing (UT) Inspection in Spokane, Washington
Atlantis NDT performs ultrasonic testing in Spokane, Washington: wall-thickness surveys on storage tanks, pressure vessels and process piping, and shear-wave examination of structural and pressure-boundary welds. Technicians are mobilized to your plant, terminal or fabrication shop with calibrated flaw detectors and thickness gauges, and every reading is reported against the code or specification you name. Describe the equipment through the Spokane UT inspection quote request and we reply within one business day.
Where ultrasonic testing is used in Spokane
Spokane sits at the center of the Inland Northwest, and its industrial base is more varied than a first look suggests. The valley east of the city holds aluminum production and the machinery that casts and processes it, precision metal fabricators, specialty chemical and electronic-materials plants, and a growing mass timber operation. Recycling and used-fluids processors operate there too. Each of those sites runs steel and aluminum equipment whose walls thin in service, which is exactly the problem ultrasonic thickness testing is built to measure.
The typical assets are easy to list. Aboveground tanks hold fuel, process liquids, water and chemicals at bulk plants and industrial sites. Pressure vessels include air receivers, heat exchanger shells, deaerators and reactor vessels. Piping carries steam, condensate, compressed gas and corrosive process fluids. Structural steel includes crane runway girders, pipe racks, equipment frames, bridges over the Spokane River and the groove welds that join all of them. A thickness survey answers whether the wall is still thicker than the minimum the owner has calculated, and a weld examination answers whether a fabrication weld contains planar flaws that a visual check cannot see.
What ultrasonic testing finds, and what it cannot
A transducer sends short sound pulses into the metal and listens for the echo. In a thickness measurement the time between the front surface and the back wall, multiplied by the sound velocity for that material, gives the remaining wall. In a weld examination an angled beam travels through the weld volume and reflects from lack of fusion, cracks, slag lines and incomplete penetration. The method sees through the whole thickness, which is why it is the standard answer for internal corrosion that cannot be seen from outside.
It has limits that matter on Spokane equipment. Sound needs a coupled, reasonably smooth surface, so heavy scale, flaking paint and rough weld caps must be dressed first. Coarse-grained cast material and some austenitic stainless welds scatter sound and need special procedures. Aluminum has a different sound velocity from steel, so a gauge calibrated on steel will read wrong on an aluminum wall, and calibration on a block of the same alloy is not optional. Pitting is the hardest case: a gauge that reads at the bottom of one pit can miss the deepest pit a few millimeters away, so the survey pattern and the reported minimum must be understood together.
Storage tanks and the ASME and API picture in Spokane
Tank questions come up in Spokane searches more than almost any other UT topic, so they get their own section. Shell courses of an aboveground tank are surveyed in vertical lines at several elevations so the owner can see where corrosion concentrates, usually near the product-water interface, around nozzles and at the lowest course. Where the owner follows API 653, the authorized inspector sets the thickness locations and decides the remaining life and next interval. Atlantis does not act as that inspector. Our role is to take the readings, record the instrument and calibration, and give the owner clean thickness grids and a list of any area below the required minimum.
Roof plates, shell-to-bottom junction welds and nozzle necks can be measured from the outside. Bottom plates are harder: spot thickness readings from the top of the floor, where it is accessible, tell part of the story, but a full floor map is a different job from a spot survey, and we say so up front. Vessels follow a parallel path. ASME Section VIII Division 1 sets the design thickness, API 510 organizes in-service inspection, and Mandatory Appendix 12 of Section VIII governs ultrasonic examination of welds when the construction code calls for it. Piping owners using API 570 or ASME B31.3 rely on the same kind of condition monitoring locations, repeated at intervals so the corrosion rate can be calculated.
Codes and acceptance criteria that govern the work
Which document governs depends on the asset. ASME Section V, Article 4 covers ultrasonic examination of welds and Article 5 covers materials, while the thickness method itself is described in SE-797, which appears in Article 23. ASTM E797 is the matching consensus practice for contact pulse-echo thickness measurement, and ASTM E164 covers contact examination of weldments. Structural groove welds in buildings and equipment frames fall under AWS D1.1, which has its own ultrasonic acceptance classes and its own scanning levels. Steel bridge work falls under AWS D1.5.
The acceptance criteria are never ours to invent. The construction code, the owner specification or the engineer of record names them, and the report quotes them. If a pipe-rack weld is accepted under AWS D1.1 and the same technician reads a reflector that the Section VIII appendix would have rejected, the report must say which rule applied and why. That discipline is the reason procedures are written before the job starts rather than adapted at the pipe.
Washington's pressure equipment rules and Spokane
Washington regulates boilers and unfired pressure vessels at the state level through the Department of Labor and Industries, and the agency reports that it inspects and permits well over a hundred thousand units. A permit is required before a boiler or unfired pressure vessel is installed, reinstalled or moved. The City of Spokane ran its own boiler and pressure vessel inspection program until it moved to the state agency on July 1, 2026, and the city keeps its boiler operator licensing. Owners who dealt with city inspectors before that date should confirm with the state boiler program who now handles their certificates.
That change does not alter what ultrasonic testing delivers. The state inspector or the owner insurer's inspector still decides on compliance. What a UT survey adds is measured data: thickness at stated locations, weld examination results and the reference to the code that was applied. Repairs and alterations to pressure equipment follow the National Board Inspection Code, and the examination records from a weld repair feed directly into that documentation. OSHA's process safety management rule, 29 CFR 1910.119(j), also expects mechanical integrity inspections that follow recognized good practice, so chemical and fuel sites often schedule thickness work around that audit cycle.
How the technique is applied
For corroded steel the standard tool is a dual-element probe, which handles rough, pitted back walls better than a single crystal. The technician calibrates on a step block of the same material, checks the velocity, verifies at the start and end of the job and again if the probe or couplant changes. An A-scan display helps keep the reading honest: a thickness number alone can hide a doubled echo or a lamination, while the waveform shows it. Hot surfaces, such as steam lines or heated process vessels, call for high-temperature probes and couplant and a correction for the temperature effect on velocity.
Weld work is different. An angle-beam probe, typically 45, 60 or 70 degrees depending on thickness and joint, is calibrated on a reference block that holds side-drilled holes so a distance-amplitude curve or reference level can be set. The technician scans from both sides where access allows, sizes any reflector against the acceptance table, and sketches its location relative to the weld centerline. Where scanning is limited by geometry, for instance a nozzle weld with a short landing, the limitation goes in the report instead of being left to the reader to guess.
Who performs and reviews the examination
Atlantis technicians are qualified under the company written practice, which follows ASNT SNT-TC-1A. The Level II technician who comes to your site calibrates the instrument, scans, and reads the screen. Procedure approval and report review sit with a Level III, who is not the person holding the probe. Our founder, Anoop Rayavarapu, holds ASNT NDT Level III in UT, RT, MT, PT and VT. Atlantis is certified to ISO 9001 and ISO 14001, which governs how the company runs its own management system, but the qualification of the individual technician rests on the written practice. An owner or code that names a different qualification scheme should say so in the inquiry. If your site needs a procedure written or a written practice reviewed, see our Level III consulting and written practice development pages.
What the Spokane UT report contains
Each report identifies the component by tag or drawing number, the procedure and its revision, the instrument, probe and calibration block, the couplant and the surface condition. For thickness work it includes a grid or table of readings by location, the nominal and minimum required thickness where the owner supplies them, and a clear list of readings below the minimum. For weld work it records the angle used, the reference level, the scan coverage, any indication with its position, length and amplitude, and the accept or reject decision against the named criteria. The technician, qualification level and date close the record. Reports are written so the owner's authorized inspector or engineer can use them directly without calling anyone to explain the notation.
Planning an ultrasonic job in Spokane
Spokane's seasons shape the work. Winter brings weeks of freezing weather, and couplant that works at room temperature stiffens or runs differently on a cold steel wall, so the technician carries a couplant suited to the temperature and checks calibration on a block kept near the part temperature. Summer sun can heat dark tank shells far above air temperature, so a probe that is comfortable at breakfast may need a high-temperature rating by afternoon. Outdoor jobs work best in the early part of the day in July, and winter jobs often move indoors or under a shelter.
Access is the other planning item. Tank shells need scaffolds or lifts, insulated pipe needs windows cut in the jacketing, and vessels need isolation and lock-out before anyone touches them. Plants in the valley run their own badging and safety orientation, and the crew should arrive with the training records the site asks for. Travel to Spokane is planned as part of the mobilization, since Atlantis has no office in the city, and a clear scope with drawings and a list of locations saves time on site more than any other single step.
UT compared with MT and PT for a Spokane job
Ultrasonic testing is the choice when the question is wall thickness or internal flaws. Magnetic particle inspection is faster and more sensitive for surface cracks in carbon steel, and our Spokane MT page covers that work. Liquid penetrant testing handles surface cracks in aluminum and stainless steel, which magnetic methods cannot, and the Spokane PT page explains it. Many jobs use two: a thickness survey on a tank shell and magnetic particle inspection of the attachment welds, or a UT weld examination on a new vessel and penetrant testing of an aluminum fitting. Our national ultrasonic testing page and the ultrasonic testing guide give the wider background.
Training your own ultrasonic technicians
Many Spokane plants prefer to train an in-house person to take routine thickness readings. Our UT Level 1 training and UT Level 2 training cover theory and practice, with the UT simulator for hands-on repetition. Certification itself is done by the employer under its written practice; see the SNT-TC-1A eligibility checker for hours and prerequisites, and the Spokane NDT training page for how courses are delivered.
Frequently asked questions
Can you measure the wall thickness of a storage tank in Spokane?
Yes. Technicians are mobilized to the tank site and take thickness readings on the shell, roof, nozzles and accessible floor areas, then report the grid against the owner's minimum. The authorized inspector decides remaining life and the next interval.
Is UT acceptable in place of radiography for a weld in Washington?
Only where the construction code and the owner allow it. Some codes include provisions for ultrasonic examination of production welds, while others require radiography. Agree the method with the owner, the engineer and the inspector before the job starts.
Will Atlantis serve as the API 510, 570 or 653 inspector on my equipment?
No. The owner's authorized inspector remains the inspector of record. Atlantis performs the ultrasonic examination and reports thickness data, indications and the calibration record so the inspector can make the required decisions.
Do you inspect aluminum with ultrasonic testing?
Yes, with a calibration block of the same alloy, because sound velocity in aluminum differs from steel. A gauge set up on steel will give wrong thickness on aluminum, so the procedure names the block and the velocity used.
Who now inspects boilers and pressure vessels in the City of Spokane?
The Washington Department of Labor and Industries took over Spokane's boiler and pressure vessel permits and inspections on July 1, 2026. The city keeps boiler operator licensing. Confirm certificates with the state boiler program.
How cold can ultrasonic thickness testing be done outdoors in Spokane?
It can continue in freezing weather with the right couplant, warmed equipment and calibration checked at a temperature close to the part. Very cold, wet or icy surfaces may call for a shelter or a different schedule.
What do I need to send for a Spokane UT quote?
Send the equipment list or drawings, the material and nominal thickness, the surface condition, insulation or coating, the governing code, the access arrangements and the dates you are aiming for. The more specific the list, the cleaner the scope.
Does Atlantis have an office in Spokane?
No. Atlantis has no office in the city. Technicians travel to your site for the agreed scope, and the quote request is the first step. Travel and mobilization are planned into the scope rather than treated as an afterthought.
Can my own staff be trained to take UT readings?
Yes. Level 1 and Level 2 courses are available, with simulator practice, and your company qualifies and certifies the technician under its own written practice. Atlantis can help review that written practice if you need one.
Inspection and training around Spokane
- Magnetic particle inspection (MT) in Spokane
- Liquid penetrant testing (PT) in Spokane
- Ultrasonic inspection services
- NDT inspection services in Washington
UT by industry for Spokane: Mining & Minerals · Pulp & Paper · Wind Energy.
UT by job: Ultrasonic pipe thickness testing · Ultrasonic weld inspection · Ultrasonic boiler tube thickness testing · Ultrasonic testing of castings and forgings.
Training your own technicians: UT Level 1 training · UT Level 2 training · NDT training for Spokane technicians.
Request an UT inspection quote for Spokane
Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for ultrasonic testing in Spokane.
Need ultrasonic testing (UT) done, or learned?