ET Level 2 Course — Eddy Current Testing Level II Training

Self-paced online NDT training to ASNT SNT-TC-1A, open to candidates worldwide. Start any time.

Local price for your country, pay with your local card, and course access opens automatically.

ET Level II under SNT-TC-1A requires 80 cumulative training hours (40 plus 40) and 840 cumulative experience hours (210 plus 630). Atlantis delivers that training under ASNT SNT-TC-1A for aerospace and aviation employers, whose written practice adds Level III-approved exams, practicals on representative hardware and per-method experience logs. Level II holds interpretation authority: reading the impedance plane and dispositioning parts.

ET Level II course facts
MethodEddy Current Testing (ET)
LevelLevel II
SchemeASNT SNT-TC-1A (employer-based)
PrerequisitesLevel I in the method (or the combined Level I + II hours); documented on-the-job experience; annual vision checks
Training hours40 h classroom + 630 h on-the-job experience (in addition to Level I: 40 h classroom, 210 h OJT) — SNT-TC-1A recommended minimums from our training requirements matrix; your written practice sets the binding figures
DeliverySelf-paced online theory with Level III support · Onsite at your facility
Practical examAdministered by an ASNT Level III under your written practice
PracticePractical NDT simulator (practice only — not a substitute for the practical exam)
InstructorAnoop Rayavarapu, ASNT NDT Level III

Request a course quote. We reply within one business day; published US fees are on the US training page.

Eddy current Level II is where the aerospace demand story concentrates. Airframe and engine inspection is fatigue-crack detection around fasteners, bolt holes, and blade roots — work that only an interpreting Level II can disposition, and the logged experience behind that authority keeps qualified supply chronically short. SNT-TC-1A sets the hours: formal training is 40+40, and experience is a cumulative 840 hours (210 plus 630). Aerospace written practices built on it add what audits look for — Level III-approved examination banks, practicals on representative hardware, per-method experience logs, individual vision tracking, and a Responsible Level 3 named in writing. General industry keeps its own Level II market in heat-exchanger tubing analysis. Method fundamentals are at /eddy-current-testing-training, the cross-method Level II view at /ndt-level-2-training, and full hour tables at /blog/ndt-training-hours-requirements-by-method.

Source: ASNT Recommended Practice No. SNT-TC-1A (2024), Table 6.3.1A; PRI Nadcap AC7114 audit criteria for aerospace written practice context

Technically reviewed by Anoop Rayavarapu — ASNT NDT Level III (UT, RT, MT, PT, VT)
ET Level II requirements: SNT-TC-1A baseline and the aerospace written practice
RequirementSNT-TC-1A (general industry)Aerospace written practice (SNT-TC-1A based)
Formal training, cumulative80 hours (40 Level I + 40 Level II)80 hours (40 Level I + 40 Level II)
Experience, cumulative840 hours (210 + 630)840 hours minimum, logged per method with dates and supervisor
General examClosed-book; content per written practiceClosed-book; Level III-approved question bank
Specific examPer written practiceCovers customer process specs and OEM procedures
Practical examCalibration, scan, evaluation on samplesProficiency demonstration on representative aerospace hardware
VisionNear-vision and color contrast; interval per written practiceNear-vision and color tracked per individual; checked at audit
Interpretation authorityEvaluates and dispositions per code/procedureSets up, standardizes, interprets, accepts/rejects; guides Level 1s
Recertification≤5-year interval per written practiceInterval per written practice, aligned to customer flow-down; refresher rules stated
Both columns are employer-based. The aerospace written practice carries Responsible Level 3 approval, which AC7114 assessors check.

The SNT-TC-1A hour-stack, and what aerospace adds

Formal training under SNT-TC-1A is 40 hours at Level I plus 40 at Level II, 80 cumulative. Experience is 210 plus 630 hours — 840 cumulative in the method — alongside a separate total-hours-in-NDT figure of 1,600 at direct-entry Level II. Aerospace written practices start from the same hour-stack and change what the hours must prove: every hour logged per method with dates and a supervising signature, on the part families the customer flows down. SNT-TC-1A's table is a recommendation employers adapt; an aerospace written practice holds its figures as firm minimums because AC7114 assessors check each record against them. Plan your timeline against the written practice your target industry actually uses; the tables for every method are at /blog/ndt-training-hours-requirements-by-method.

Interpretation authority: the impedance plane is the job

An ET Level II's defining skill is reading the impedance plane — the two-dimensional display where every signal is a vector whose phase and amplitude encode what caused it. Lift-off sweeps one direction; conductivity change another; a surface crack breaks the eddy current flow with a phase signature that deepens predictably with flaw depth. The Level II separates these in real time, on parts where edge effect, fastener geometry, and permeability noise all crowd the screen. Under every written practice, that judgment carries disposition authority: accept, reject, document, and defend. It is also why the experience walls exist — phase discrimination is pattern recognition, and pattern recognition is built only from hours of standardized, supervised looking.

Why aerospace demand concentrates at ET Level II

Aerospace is the largest eddy current employer because the method is unmatched for surface and near-surface fatigue cracks in conductive alloys — exactly the failure mode that governs aircraft structures. Airframe programs inspect fastener holes and skin around them; engine shops inspect disk bores, blade roots, and dovetails; MRO stations re-inspect on every heavy check. All of it requires an interpreting Level II under an aerospace written practice, and the 840 logged experience hours behind each one mean supply cannot surge when demand does. The result is a persistent seller's market for certified aerospace ET Level IIs, concentrated around US aerospace hubs — Wichita, the Puget Sound, Connecticut's engine corridor, and the Texas and Florida MRO belts.

The general-industry Level II market: tubing analysis

Outside aerospace, the strongest ET Level II demand is heat-exchanger and condenser tubing inspection in power and process plants. Bobbin coils fly through thousands of tubes per outage shift, generating data that a certified analyst must interpret: distinguishing wall loss, pitting, and cracking from support-plate signals and deposits, sizing indications in percent through-wall, and dispositioning tubes for plugging. This is SNT-TC-1A territory — 840 cumulative hours — and it is one of the few NDT roles that can be performed substantially off-site, since analysis happens on recorded data. Nuclear plants layer additional qualification requirements on top, making experienced tubing analysts among the best-compensated Level IIs in general industry.

Exams in general and aerospace programs — and where candidates fail

SNT-TC-1A prescribes the familiar trio — general, specific, practical — at a recommended 80 percent composite, with content set by the written practice. Aerospace written practices harden the structure: the general exam is closed-book from a Level III-approved question bank; the specific covers the employer's specifications and techniques; and the practical is a proficiency demonstration on representative hardware, from setup and standardization through scan, interpretation, and documentation. Failure patterns are consistent across both: candidates pass the written exams and stumble on practical interpretation — misreading phase on a bolt-hole standard, or failing to re-verify standardization after a probe change. An aerospace written practice also states the documented remedial training required before any re-examination.

Vision requirements: tracked per person, audited in aerospace

SNT-TC-1A's regime — near-vision at Jaeger No. 2 or equivalent from not less than 12 inches, plus color-contrast differentiation, at intervals the written practice sets — is the baseline. Aerospace written practices track both examinations per individual for every certified level, because AC7114 assessors read each date. For eddy current the color requirement is functional, not formal: modern instruments encode channels and alarm states in color, and array systems paint C-scans in graded palettes. Lapsed vision exams suspend certification immediately under any written practice, and aerospace auditors check vision records with the same rigor as exam scores — an easily avoided finding that shows up in real audits constantly.

What ET Level II pays in the US

ZipRecruiter's NDT Level 2 band runs $48,000 to $90,000 with top earners above it, and the BLS median for all nondestructive testing specialists sits at $78,350 (May 2025). Aerospace ET Level IIs cluster in the upper half of that range: the logged experience aerospace audits demand restricts supply, and primes pay for it — with engine-shop and nuclear tubing-analysis roles at the top of the method. Multi-technique holders (surface, bolt-hole rotary, array, tubing) out-earn single-technique peers consistently. US-first bands by method, industry, and region — including how aerospace ET compares against pipeline RT and PAUT premiums — are maintained at /blog/ndt-salary-guide-2026-global.

Routes to ET Level II: ladder, direct, and crossover

Three routes lead here. The ladder route certifies Level I first — 40 hours training, 210 experience hours — then adds the second 40-hour course and remaining hours. The direct route runs the full stack as a documented trainee: 80 training and 840 experience hours under SNT-TC-1A, then examines straight to Level II. The crossover route brings a certified ET Level II across the industry boundary — general industry to aerospace or back — carrying training certificates and logged hours but requiring full re-examination under the new employer's written practice, including aerospace practicals, Level III-approved exams and vision tracking when moving toward aerospace. Complete personal records make every route faster.

Training ET Level II with Atlantis

Atlantis NDT's 40-hour ET Level II course is built around interpretation: impedance-plane analysis drills, phase-depth discrimination on EDM-notched standards, bolt-hole and surface-scan practicals, and tubing-signal fundamentals — delivered under ASNT SNT-TC-1A for aerospace, aviation MRO and general industry employers alike. For employers, our ASNT Level III consultants deliver the full program: SNT-TC-1A written practices aligned to customer flow-down requirements and AC7114, controlled examination banks, individual vision tracking, and audit-ready records, with the employer signing the certification. Affordable, accessible, fully customizable to your hardware and specifications. Start from aerospace NDT training, aviation NDT training, /eddy-current-testing-training and /ndt-level-2-training, then request a quote for seats or a complete certification program.

Why do aerospace employers ask for more than the SNT-TC-1A minimums?

Aerospace eddy current findings disposition fatigue-critical hardware — engine disks, wing attachments, bolt holes — where a missed crack is catastrophic. Aerospace written practices hold the SNT-TC-1A hours as firm minimums and add dated logs, Level III-approved exams and practicals on real hardware, which buys judgment that classroom hours cannot.

What does an ET Level II do that a Level I cannot?

Set up and standardize equipment from scratch, choose frequencies and probes within procedure limits, interpret impedance-plane signals — separating cracks from lift-off, edge effect, and permeability noise — accept or reject parts, document dispositions, and supervise Level I technicians and trainees.

How long does it take to reach ET Level II in aerospace?

With SNT-TC-1A's 840 cumulative experience hours, a full-time trainee needs roughly five to seven months of logged method time plus 80 training hours and exams. Where the aerospace written practice flows down more hours or part-specific practicals, plan for about a year.

Is heat-exchanger tubing analysis a Level II job?

Yes — bobbin and array tubing data analysis is a classic SNT-TC-1A Level II role. Outage crews collect terabytes of coil data; certified analysts interpret signals, size wall loss, and disposition tubes, often remotely from the data they are fed.

Do aerospace employers accept SNT-TC-1A ET Level II?

Yes, as a foundation. Aerospace employers certify under their own written practice, which Atlantis builds on SNT-TC-1A with the primes' flow-down requirements added. Your training and logged hours carry over, but the employer must examine and certify you under that written practice, including its Level III-approved exams, practicals on aerospace hardware and vision tracking.

What surface techniques does aerospace ET Level II cover?

Pencil-probe scanning around fastener heads and radii, automated rotary bolt-hole inspection, conductivity verification for alloy and heat-treat condition, and increasingly eddy current array for coverage-critical surfaces — each standardized on reference standards with EDM notches.

Request a consultation

Get certified, or certify your team

Individuals train and sit examinations under their employer's written practice. Employers need that written practice, and a Level III to run it. Atlantis does both.

Start NDT training any time of year

Enrolment is open throughout the year. Courses are primarily self-paced, so you can join at any time and work through the learning material around your schedule.

Monthly starts
Portal access opens the moment you enrol, at any time of year.
Level III support
Level III support is available throughout the year for course clarifications. Confirm the contact method and arrangements when you enrol.
Practical arrangements
Practicals are done in the Practical NDT simulator and in person at your employer’s facility, on its equipment and parts. Simulator practice supports training; it does not replace supervised experience, the practical examination or employer certification.

Ask about enrolment and practical arrangements

Ask about NDT training and practical arrangements

Tell us the methods and levels you need, how many technicians and where they work. We reply within one business day with the delivery options that fit, how the practical at your facility would work, and what your written practice requires.

Request a quote / enrol · Employer-sponsored training · info@atlantisndt.com