Tank Inspection Services in Oman 2026 — ASNT Level III Led
Atlantis NDT delivers tank inspection services in Oman. Methods: UT (including PAUT and TOFD), RT, MT, PT and VT, with procedures and reports reviewed by an ASNT NDT Level III. Oman facilities in the EOR, LNG & petrochemical sectors require rigorous tank inspection services. Technicians are certified by their employer to its SNT-TC-1A written practice.
Tank Inspection Services Scope
Tank inspection covers: floor plates and bottom annulus via MFL; shell courses via UT thickness survey; roof, nozzles, and foundation via visual and settlement measurement — all per API 653, with API 650 new-construction alignment and EEMUA 159 guidance where applicable. Atlantis NDT Level III approves every Procedure + signs off final disposition + audit-ready records via Atlantis NDT ERP.
Code + Compliance
Tank Inspection Services per: ASME B&PV Sections V + VIII + IX + XI; ASME B31 piping series; API 510 + 570 + 571 + 579 + 580 + 581 + 653 + 1104 + 1169; ASTM E-series; ISO 17635/17636/17640; AWS D1.1/3.6; IACS Rec-20 marine; NACE MR0175 + MR0103 sour-service.
Free Consultation
Atlantis NDT publishes no pricing — varies by region + scope. Request your free 30-minute consultation. Every job is quoted on request. See also verticals, Oman ERP, Oman training, Oman consulting.
What tank inspection involves
Aboveground storage tank inspection covers the shell, floor, roof and appurtenances, establishing minimum thickness by course, floor condition, settlement, and the resulting inspection intervals under API 653.
Scope of work
- External inspection of shell, roof, appurtenances, foundation and containment
- Ultrasonic shell thickness by course with minimum-required-thickness calculation
- Floor scanning by magnetic flux leakage with ultrasonic prove-up of indications
- Settlement survey and evaluation against API 653 Annex B criteria
- Vacuum box testing of floor welds and, where required, hydrostatic testing after repair
Governing codes
API 653 for inspection, repair, alteration and reconstruction, API 650 as the construction code, API 575 for practice, and API 579 where fitness-for-service assessment is required.
The Oman asset base
Oman operates a strategically critical hydrocarbon sector spanning Petroleum Development Oman's onshore production (>700,000 bpd from Mukhaizna, Marmul, Yibal, Lekhwair), the OQ refining complex at Sohar plus the OQ Salalah methanol plant, and the Oman LNG export terminal at Qalhat (Sur) with 10.4 mtpa capacity. The Ministry of Energy and Minerals oversees integrity management across PDO, OQ, BP Khazzan (deep gas), and Daleel Petroleum assets. Remote desert location, sour-gas production, and the strategic location at the mouth of the Strait of Hormuz make digital twin remote-monitoring and life-extension evidence a strong fit for Oman operators.
How the work is controlled
Agree personnel qualification, equipment checks, procedure revision and review responsibilities for the examination. Retain those records with the results and coverage limitations.
What you receive
- A report in your required format, with findings located against the component and, where relevant, against a persistent corrosion monitoring location so trends stay continuous between campaigns
- Raw data in the instrument-native format plus an open export, so the dataset outlives any single supplier relationship
- The procedure revision, technician certification state and instrument calibration status applicable at the time of examination
- Where a finding affects continued service, the specific code clause governing the acceptance decision
Related: asset integrity management software · inspection management software · ASNT Level III consulting · digital twin for asset integrity. Request a quote for Oman.