Construction NDT Services in Miami 2026 — ASNT Level III Led
Atlantis NDT delivers construction ndt services in Miami. ASNT NDT Level III-led. Technicians are certified by their employer to its SNT-TC-1A written practice, and procedures and reports are reviewed by an ASNT NDT Level III (UT, RT, MT, PT, VT).
Construction Inspection Scope in Miami
Comprehensive NDT inspection for Construction facilities: pressure vessels (API 510), piping (API 570), above-ground storage tanks (API 653), heat exchangers + columns, fired heaters + furnaces, offshore platforms + FPSOs (where applicable), turnaround + EPC project support. Methods: UT (including PAUT and TOFD), RT, MT, PT and VT.
Code + Compliance
Construction facility inspections per: ASME B&PV Sections V + VIII + IX + XI; ASME B31 piping series; API 510 + 570 + 571 + 653 + 936 + 1169; NACE MR0175 + MR0103 sour-service; ASTM E-series; ISO 17635/17636/17640; AWS D1.1/3.6; IACS Rec-20 marine. Records are retained in Atlantis NDT ERP.
Free Consultation in Miami
Atlantis NDT publishes no pricing — pricing varies by region + scope + delivery model. Request your free 30-minute consultation with founder Anoop Rayavarapu (ASNT NDT Level III in UT, RT, MT, PT and VT). Every job is quoted on request. See also verticals, consulting, Miami ERP, Miami training.
What construction inspection actually covers
Assets in scope: structural steel frames and connections, reinforced concrete elements, pipe racks, cranes and lifting structures, foundations and anchor systems, and site-fabricated pressure piping.
Damage mechanisms that drive the inspection plan
Weld defects at connections — lack of fusion, undercut, toe cracking; fatigue at cyclically loaded details; corrosion at embedments, splash zones and coating breakdowns; concrete cover loss and reinforcement corrosion; and misalignment or distortion from erection.
Methods applied
Visual examination to a written procedure as the primary method, magnetic particle and penetrant for surface indications, ultrasonic and phased array for weld volume, radiography where access allows, plus concrete cover meters and rebound testing on reinforced elements.
Governing codes and standards
AWS D1.1 for structural steel welding, ASME B31.3 for process piping on industrial sites, ASME Section IX for welder qualification, ACI standards for concrete, and the project inspection and test plan which usually governs hold points more strictly than any code.
What makes this sector different
On construction projects the quality record is what gets audited rather than the programme — welder qualification continuity, NDT results tied to specific joints and drawings, material traceability by heat number, and hold-point evidence signed by the party the ITP names.
Working in Miami
Scope in Miami is set by the local asset base, the client's own vendor-approval regime and the inspection intervals required by the governing in-service code. Mobilisation, permit and access planning are agreed before the crew travels, because on most sites those constraints decide the cost of a campaign more than the examination itself does.
How the work is controlled
Agree personnel qualification, equipment checks, procedure revision and review responsibilities for the examination. Retain those records with the results and coverage limitations.
Related: ASNT Level III consulting · NDT training and certification · inspection management software · asset integrity management software. Request a quote for Miami.
Construction NDT beyond Miami
This page covers construction inspection in Miami. The sector-wide picture sits on the national pages: construction NDT training covers the methods this sector certifies in and the career path into it.