NDT Training and Certification in New Hampshire: Online and Onsite ASNT Courses

Self-paced online NDT training to ASNT SNT-TC-1A, open to candidates worldwide. Start any time.

Local price for your country, pay with your local card, and course access opens automatically.

Atlantis NDT delivers ASNT SNT-TC-1A NDT training for employers and technicians in New Hampshire: Level I, Level II and Level III programmes across ultrasonic, radiographic, magnetic particle, penetrant, eddy current and visual testing. Courses are authored and supervised by ASNT NDT Level III professionals.

Two training routes for New Hampshire

I'm an individual technician

You want Level I or Level II in one method, or you are preparing for ASNT Level III. Theory is online and primarily self-paced, with access from the moment you enrol; your employer (or the employer you are joining) certifies you under its written practice, and the practical examination is administered by an ASNT Level III on real specimens. Send a course enquiry or read NDT training online first.

I'm training a company team

You need a crew trained, examined and certified to your SNT-TC-1A written practice, onsite at your facility or blended with online theory, with Level III oversight and an audit-ready file. See the SNT-TC-1A certification programme for NDT companies or request a company team training quote. We reply within one business day.

The New Hampshire inspection market

Seabrook Station, operated by NextEra Energy, is New Hampshire's only nuclear plant and is licensed to operate through 2050. BAE Systems' Nashua microelectronics center is a DoD-designated Trusted Foundry producing defense and satellite chips, with a CHIPS Act-funded modernization underway. Portsmouth Naval Shipyard, physically located across the river in Kittery, Maine, draws more than 3,100 New Hampshire residents into its submarine-maintenance workforce — a real workforce story rather than an in-state facility claim — and the Merrimack Valley hosts a diversified cluster of precision-machining and advanced-manufacturing suppliers. New Hampshire's industrial base is narrower than most states with an established training presence, but Seabrook and BAE's Trusted Foundry are genuine, verifiable anchors.

Certifications most in demand in New Hampshire

Atlantis trains to ASNT SNT-TC-1A. Some local employers also ask for ISO 9712, a separate scheme sat through its own body; Atlantis does not train or examine for it.

Third-party examination centres named for this market

These are run by other organisations, not by Atlantis; Atlantis has no exam centre or practical facility in New Hampshire.

Recommended certification pathway

Seabrook Station qualifies personnel under ASNT SNT-TC-1A with ASME Section XI in-service inspection under NRC oversight; BAE Systems' Nashua Trusted Foundry applies Nadcap AC7114 overlays for defense-microelectronics package inspection, with most roles requiring a DoD security clearance.

Delivery formats

NDT training across USA

Nearby markets with their own training pages (training is online, with practicals at your facility):

Frequently Asked Questions

Where can I take ASNT NDT training in New Hampshire?

Atlantis NDT runs ASNT SNT-TC-1A Level I/II/III programmes for candidates in New Hampshire, USA, delivered as online, primarily self-paced theory with practical training in the Practical NDT simulator and in person at your facility; Atlantis has no training centre in New Hampshire. Seabrook Station qualifies personnel under ASNT SNT-TC-1A with ASME Section XI in-service inspection under NRC oversight; BAE Systems' Nashua Trusted Foundry applies Nadcap AC7114 overlays for defense-microelectronics package inspection, with most roles requiring a DoD security clearance.

Which certification should an inspector in New Hampshire take first?

Seabrook Station qualifies personnel under ASNT SNT-TC-1A with ASME Section XI in-service inspection under NRC oversight; BAE Systems' Nashua Trusted Foundry applies Nadcap AC7114 overlays for defense-microelectronics package inspection, with most roles requiring a DoD security clearance.

Does Atlantis run corporate on-site NDT training in New Hampshire?

Yes. On-site courses run for an employer's own team at its facility in or around New Hampshire, with method-specific practical sessions on your own equipment and specimens, so the training maps to the work your crews actually do. Written practice review and Level III oversight can be bundled with the programme.

Related: NDT training programmes · ASNT certification guide · ASNT Level III consulting. Ask about training for New Hampshire.

NDT training in New Hampshire: how it works for New Hampshire employers and technicians

Short answer: Atlantis NDT delivers ASNT SNT-TC-1A-based NDT training for New Hampshire employers and technicians, from the Seacoast and the Merrimack Valley to the Upper Valley and the North Country. Level I, II and III courses in UT, PAUT, TOFD, RT, MT, PT, VT and ET run self-paced online or onsite at your facility under ASNT Level III oversight. Your employer certifies you against its written practice after training, experience, exams and a vision test. There is no Atlantis training centre in New Hampshire.

New Hampshire's inspection work is concentrated in a handful of demanding sectors: aerospace and precision manufacturing in the Merrimack Valley and along the Route 101 and Route 16 corridors, nuclear and conventional power on the Seacoast and the Merrimack River, submarine maintenance just across the Piscataqua, and a steady stream of bridge, pipeline and plant work. Most of the companies involved are small or mid-sized manufacturers and contractors who need a few people qualified at a time, to exacting customer requirements, without losing them to a week or more of out-of-state classes. This section explains what Atlantis teaches, how SNT-TC-1A certification works, how training reaches New Hampshire, and what local employers and regulators expect.

If you already know the methods and headcount, request a New Hampshire training quote. We reply within one business day.

ASNT Level I, II and III courses available in New Hampshire

Every course follows ASNT SNT-TC-1A, so topic outlines and examinations can be written straight into your employer's written practice. Examples are chosen for New Hampshire work: investment and sand castings, machined and forged aerospace parts, composite and metallic engine components, power-plant piping and heat exchangers, submarine-related fabrication for shipyard suppliers, bridge steel, and process and pressure equipment in manufacturing plants.

MethodLevelsWhat New Hampshire employers use it forPrerequisite
Ultrasonic testing (UT)I, II, III prepForgings and machined parts, power-plant piping thickness and weld examination, bridge weld inspectionNone for Level I; Level I plus documented experience for Level II
Phased array UT (PAUT)IIWeld and component inspection where coverage and recorded data are required, including power and heavy fabricationUT Level II or equivalent
Time-of-flight diffraction (TOFD)IIFlaw sizing on thick welds in pressure equipment and power-plant componentsUT Level II
Radiographic testing (RT)I, II, III prepCasting radiography for aerospace and industrial foundries, weld radiography on piping and vesselsNone for Level I; radiation safety training and state requirements for field work
Magnetic particle testing (MT)I, IIFerromagnetic forgings, gears and shafts, structural and bridge weldsNone for Level I
Liquid penetrant testing (PT)I, IIFluorescent penetrant on castings and machined aerospace and defence parts, stainless and non-ferrous componentsNone for Level I
Visual testing (VT)I, IIWeld visual on fabrication, bridge and plant work; remote visual and borescope inspectionNone for Level I
Eddy current testing (ET)I, IISurface and bolt-hole inspection of aerospace parts, condenser and heat-exchanger tubing, conductivity checksNone for Level I

Ultrasonic testing. UT Level I covers wave theory, transducers, reference standards, straight-beam, angle-beam and immersion concepts, and thickness gauging. Level II adds DAC and TCG, flaw location and sizing, and interpretation against the applicable specification. In New Hampshire, UT is used both on the precision-manufacturing side, on forgings, bar and machined parts, and on the plant side, for piping thickness surveys and weld examination.

PAUT and TOFD. At Level II these cover focal laws, sectorial and linear scans, encoded acquisition, TOFD geometry, analysis and reporting. They are increasingly requested by power and fabrication clients who want recorded, auditable UT data rather than a technician's sketch.

Radiographic testing. RT covers radiation physics, X-ray and isotope sources, film, computed and digital radiography, exposure technique, image quality and interpretation of casting and weld discontinuities. Foundries and casting suppliers in the state use cabinet and shielded-room radiography; field radiography requires state licensing, covered below.

MT, PT and VT. Fluorescent penetrant is one of the most widely used methods in New Hampshire because of the concentration of casting and aerospace machining suppliers; the course covers penetrant families, sensitivity levels, pre-cleaning, dwell, removal and developer technique. MT covers wet fluorescent bench inspection and portable yoke technique. VT covers direct and remote visual, measurement tools and acceptance criteria.

Eddy current. ET covers impedance-plane theory, surface and bolt-hole probes, conductivity and coating measurement, and bobbin-probe tubing inspection. It supports aerospace maintenance and manufacturing and power-plant heat-exchanger work.

Level III preparation. Experienced technicians can prepare for the ASNT Level III Basic and method examinations through ASNT Level III training, including procedure writing and running a certification programme.

SNT-TC-1A certification path in New Hampshire, step by step

New Hampshire does not license NDT technicians. Under SNT-TC-1A your employer certifies you against its written practice:

  1. Employer written practice setting out levels, methods, training and experience requirements, exam content and grading, and recertification.
  2. Classroom training to the hours the written practice specifies. The training requirements matrix summarises the current recommended figures.
  3. On-the-job experience in the method under supervision, logged separately from training hours.
  4. General examination on method theory.
  5. Specific examination on your employer's equipment, procedures, customer specifications and acceptance criteria.
  6. Practical examination on real specimens with known discontinuities, administered and graded under a Level III.
  7. Vision examination: near-vision acuity and colour-contrast differentiation, with near vision every year.
  8. Certification issued by the employer and kept on file for customer and auditor review.
  9. Recertification at the interval in the written practice, by examination or evidence of continuing performance where permitted.

See SNT-TC-1A training and certification for a fuller walkthrough.

Self-paced online or onsite NDT training for New Hampshire crews

New Hampshire employers typically need small groups trained without stopping production. Delivery options are:

  • Self-paced online theory. Theory with ASNT NDT Level III support that technicians in Nashua, Manchester, Portsmouth, Concord, Keene, Lebanon or the Lakes Region can study from work or home. See online NDT training.
  • Onsite at your facility. The instructor trains at your plant or shop, on your equipment and parts, and can administer examinations under Level III oversight. For manufacturers with penetrant lines, radiography rooms or immersion tanks, this keeps the practical tied to the process the technician will actually run.
  • Blended. Online theory first, then a concentrated onsite practical block.

Scheduling follows your year: power-plant refuelling and maintenance outages, manufacturing ramp-ups for aerospace delivery schedules, and the construction season for bridge and infrastructure contractors, which in northern New England is compressed by winter. Tell us your windows and we plan training ahead of them. Ask about onsite training for your New Hampshire crew, or see corporate NDT training.

Where NDT technicians work in New Hampshire

  • Aerospace and precision manufacturing. The state hosts aircraft-engine component production, including GE Aerospace's Hooksett plant, the Safran and Albany composite fan-blade and case operations in Rochester, investment-casting producers such as Hitchiner Manufacturing in Milford, and a dense network of machining, forging and bearing suppliers. Atlantis SNT-TC-1A training builds that knowledge, and its ASNT Level III consulting aligns written practices to the customer’s flow-down.
  • Nuclear power. Seabrook Station on the Seacoast is New Hampshire's nuclear plant. In-service inspection during refuelling outages follows ASME Section XI, usually with ANSI/ASNT CP-189 certification and, for some UT, performance demonstration requirements, managed by the utility and its ISI contractors.
  • Conventional power and energy. Merrimack Station in Bow, gas-fired plants, hydroelectric dams and biomass plants create boiler, piping and heat-exchanger inspection to ASME Section I and B31.1. Natural gas transmission and distribution lines bring API 1104 weld inspection and integrity work under PHMSA rules.
  • Submarine maintenance. Portsmouth Naval Shipyard in Kittery, Maine, employs many New Hampshire residents, and its supply chain includes New Hampshire fabricators and machine shops. Naval work uses NAVSEA technical publications for NDT qualification and acceptance, which sit alongside SNT-TC-1A; confirm the specific NAVSEA requirement with the shipyard or prime before enrolling.
  • Defence and aviation. Pease Air National Guard Base in Portsmouth, home to an air refuelling wing, and defence electronics and firearms manufacturers across the southern tier add ET, PT and UT work.
  • Bridges and infrastructure. The New Hampshire Department of Transportation manages a large inventory of bridges, many of them steel, and fabrication and rehabilitation work follows AWS D1.5, with UT and MT on welds and VT throughout.

Radiography licensing in New Hampshire. New Hampshire is an NRC Agreement State. Radioactive materials licences, including industrial radiography, and X-ray equipment registration are administered by the state's radiological health programme within the Department of Health and Human Services. A company performing field radiography needs a state licence with a radiation safety programme and radiation safety officer; radiographers need radiation safety training and a qualifying radiographer certification, and work under two-person, survey and dosimetry requirements at temporary job sites. Work at Seabrook falls under the utility's NRC-licensed programme, and work at the naval shipyard in Maine falls under federal and Maine requirements. Atlantis RT courses cover interpretation competence, not licensing.

What New Hampshire employers ask for. Some clients also require an AWS CWI, which Atlantis prepares candidates for in a six-day exam-prep course.

Level III services and written practices for New Hampshire NDT companies

Many New Hampshire suppliers perform NDT in-house with a small team and no resident Level III, yet face some of the most rigorous customer audits in industry. Atlantis provides outsourced Level III support:

  • Written practice development and gap reviews against the current SNT-TC-1A edition, structured so customer auditors can follow it; see written practice development.
  • Procedures and technique sheets written to customer and code requirements.
  • Examinations prepared, administered and graded under Level III authority, with records ready for audit.
  • Audit preparation for customer source inspections, supplier qualification and ISO 9001 surveillance.

For the rules, see SNT-TC-1A guidance. To discuss your programme, book a Level III consultation.

Practise before the practical exam

Trainees can rehearse techniques with Practical NDT, the Atlantis 3D simulator, which covers 12 method families in twelve workplaces, including an NDT lab, a welding workshop, an aircraft hangar, an oil and gas site and a storage tank. The hangar environment is particularly relevant to New Hampshire aerospace and aviation technicians, and repetition helps set-up and scan technique become second nature before practical sessions.

The simulator is practice only. It does not replace hands-on training, and it does not replace the practical examination, which must be performed on real specimens and graded under Level III authority. For written-exam revision, see the UT Level 2 practice questions.

Your instructor

Training is led by Anoop Rayavarapu, ASNT NDT Level III and founder of Atlantis NDT. Anoop authors the course content, provides Level III oversight of examinations and works directly with New Hampshire employers on written practices and programme structure.

Frequently asked questions about NDT training in New Hampshire

How do I get NDT certified in New Hampshire?

New Hampshire has no state NDT licence. Under ASNT SNT-TC-1A your employer certifies you after classroom training, supervised experience, general, specific and practical exams under a Level III, and a vision test. PT or UT Level I training is a sensible first step for jobs with manufacturers and inspection contractors.

Can I take NDT training online in New Hampshire?

Yes, the classroom theory is available self-paced online statewide. The practical training and exam require real equipment and specimens, normally onsite at your employer. See online NDT training.

How long does UT Level 2 training take?

It depends on your employer's written practice and your existing training and experience. SNT-TC-1A recommends minimum classroom and experience hours for each level; see the training requirements matrix, then send us your hours so we can map what remains.

Do I need a license for radiography in New Hampshire?

The company needs a state radioactive materials licence or X-ray registration, because New Hampshire is an NRC Agreement State. Field radiographers need radiation safety training and a qualifying radiographer certification and work under the licensee's programme. SNT-TC-1A RT certification is not a radiation licence.

What does NDT training cost in New Hampshire?

Quote on request, depending on method, level, number of trainees, delivery format and whether examinations and Level III services are included. We reply within one business day: request a New Hampshire quote.

Is ASNT certification recognised by New Hampshire employers?

Yes, SNT-TC-1A is the default framework for most US industrial employers.

Can I work at Portsmouth Naval Shipyard with SNT-TC-1A certification?

Naval shipyard and submarine work applies NAVSEA technical publications for NDT personnel qualification, and the shipyard or prime sets the requirement. SNT-TC-1A method training is useful preparation, but confirm the specific requirement before enrolling.

Which NDT method is most in demand in New Hampshire?

Fluorescent penetrant and UT are the most widely used because of the aerospace and casting supply chain. RT is important for foundries, ET for aviation, and MT and VT for plant and bridge work.

Can you train our inspectors at our plant in the Merrimack Valley or on the Seacoast?

Yes. Onsite training at your facility is the usual model for groups, on your equipment and parts, with examinations under Level III oversight.

Can a New Hampshire manufacturer certify its own NDT staff?

Yes, with a compliant written practice and a qualified Level III to administer exams and sign certifications. Many use an outsourced Level III; see written practice development.

What do NDT technicians earn in New Hampshire?

Pay depends on method, level and sector, and aerospace, nuclear and plant roles differ. For sourced ranges, see the NDT salary guide 2026.

Next steps: request a New Hampshire training quote, browse all NDT training programmes, or speak to a Level III about your written practice.

Cities we serve in New Hampshire

NDT training and certification from New Hampshire

There is no Atlantis classroom in New Hampshire. You study the theory online at your own pace, practise in the Practical NDT simulator, and complete hands-on training and the practical examination at your employer's facility, under a written practice built on ASNT SNT-TC-1A. The published US fees are on this page, and Register & Buy Now opens the course on the Atlantis portal.

AWS CWI exam prep for New Hampshire

Welders, QC inspectors and fabrication staff in New Hampshire who want the AWS Certified Welding Inspector credential can take our six-day CWI exam prep course in three formats: corporate for a team at your facility, online at your own pace, or one-to-one, online or in person. AWS administers the examination and issues the certification.

Start NDT training any time of year

Enrolment is open throughout the year. Courses are primarily self-paced, so you can join at any time and work through the learning material around your schedule.

Monthly starts
Portal access opens the moment you enrol, at any time of year.
Level III support
Level III support is available throughout the year for course clarifications. Confirm the contact method and arrangements when you enrol.
Practical arrangements
Practicals are done in the Practical NDT simulator and in person at your employer’s facility, on its equipment and parts. Simulator practice supports training; it does not replace supervised experience, the practical examination or employer certification.

Ask about enrolment and practical arrangements

NDT training fees — United States

Published fees for ASNT SNT-TC-1A Level I and Level II training in the United States, and for the online Level III refresher. All fees are in US dollars.

Level I and Level II five-method packages (VT, PT, MT, UT, RT), USD
PackageTraining hoursPackage fee
Level I — all 5 methods104 hours$2,799
Level II — all 5 methods112 hours$2,799
Level I or Level II, one method at a time, USD
MethodFee per method
Visual Testing (VT)$349
Penetrant Testing (PT)$399
Magnetic Particle Testing (MT)$399
Ultrasonic Testing (UT)$799
Radiographic Testing (RT)$899
Level III online refresher (self-paced, exam-focused), per method, USD
Level III refresherFee per method
Basic (general examination)$1,260
Ultrasonic Testing (UT)$1,260
Radiographic Testing (RT)$1,260
Magnetic Particle Testing (MT)$900
Liquid Penetrant Testing (PT)$900
Visual Testing (VT)$900
Register & Buy Now

The Atlantis course page shows the price for your country. Pay with your local card and your course access opens automatically.

  • Level I and Level II: materials and exam preparation are included. Training hours follow the recommended initial hours in ASNT SNT-TC-1A Table 6.3.1A; final hours are set by the employer's written practice.
  • Payment: 50% in advance to start training, with the 50% balance due before the certificate is issued. Applicable taxes may apply.
  • Level III refresher: fees cover online course access, study materials, mock exams and instructor support. ASNT examination fees are paid separately to ASNT and are not included.
  • Fees are subject to change. Group and corporate programmes are quoted on request.

Published fees for other regions: Middle East, Europe, South East Asia. Training outside the United States, the Middle East, Europe and South East Asia (including Canada, Australia, New Zealand and Africa)? Contact us for fees in your region.

Seabrook Station, operated by NextEra Energy, is New Hampshire's only nuclear plant and is licensed to operate through 2050. BAE Systems' Nashua microelectronics center is a DoD-designated Trusted Foundry producing defense and satellite chips, with a CHIPS Act-funded modernization underway. Employers here ask for ASNT and ISO 9712 certification; Atlantis training runs to ASNT SNT-TC-1A, with online theory and practicals in the simulator and at your facility.

Portsmouth Naval Shipyard, physically located across the river in Kittery, Maine, draws more than 3,100 New Hampshire residents into its submarine-maintenance workforce — a real workforce story rather than an in-state facility claim — and the Merrimack Valley hosts a diversified cluster of precision-machining and advanced-manufacturing suppliers. New Hampshire's industrial base is narrower than most states with an established training presence, but Seabrook and BAE's Trusted Foundry are genuine, verifiable anchors. Seabrook Station qualifies personnel under ASNT SNT-TC-1A with ASME Section XI in-service inspection under NRC oversight; BAE Systems' Nashua Trusted Foundry applies Nadcap AC7114 overlays for defense-microelectronics package inspection, with most roles requiring a DoD security clearance. Employer examinations (general, specific and practical) are administered by an ASNT Level III under your written practice; ASNT's own central examinations are booked through ASNT's testing arrangements, not through Atlantis.

Source: ASNT SNT-TC-1A (2024 edition); local market data per city research file

NDT training and certification in New Hampshire — route, pay and delivery
FactorThis marketWhat it means
Certification routeASNT, ISO 9712Seabrook Station qualifies personnel under ASNT SNT-TC-1A with ASME Section XI in-service inspection under NRC oversight; BAE Systems' Nashua Trusted Foundry applies Nadcap AC7114 overlays for defense-microelectronics package inspection, with most roles requiring a DoD security clearance.
Level I pay band—Entry: performs set-ups and records results under supervision
Level II pay band—Interprets and reports to an approved procedure
Level III pay band—Approves procedures and qualifies personnel
ExaminationsEmployer exams by an ASNT Level III under your written practiceNo Atlantis exam centre; ASNT central exams via ASNT's own testing arrangements
DeliveryOnline theory, primarily self-paced · practicals in the Practical NDT simulator and in person at your facilityNo Atlantis training centre here; enrol any time of year, with access from the moment you enrol

Which NDT certification do employers in New Hampshire ask for?

ASNT SNT-TC-1A leads this market; ISO 9712 appears on some contracts as a separate scheme that Atlantis does not deliver. Seabrook Station qualifies personnel under ASNT SNT-TC-1A with ASME Section XI in-service inspection under NRC oversight; BAE Systems' Nashua Trusted Foundry applies Nadcap AC7114 overlays for defense-microelectronics package inspection, with most roles requiring a DoD security clearance.

What does an NDT technician earn in New Hampshire?

Level I sits at the local entry band, Level II at the local qualified band, and Level III at the senior band. Certification level moves pay more than any other factor; method premiums stack on top.

Where are NDT certification exams administered near New Hampshire?

Employer examinations (general, specific and practical) are administered by an ASNT Level III under your written practice; ASNT's own central examinations are booked through ASNT's testing arrangements, not through Atlantis. Employer-certified schemes also allow examinations at the employer's own facility under an approving Level III.

How is NDT training delivered in New Hampshire?

Online and in person. Theory is online and primarily self-paced: you can enrol any time of year, with access from the moment you enrol and Level III support for course questions. Practical training runs in the Practical NDT simulator and in person at your employer's facility, on its own equipment, and the practical examination is taken on real specimens under the employer's written practice. Atlantis has no training centre or classroom in New Hampshire.

Ask about NDT training and practical arrangements

Tell us the methods and levels you need, how many technicians and where they work. We reply within one business day with the delivery options that fit, how the practical at your facility would work, and what your written practice requires.

Request a quote / enrol · Employer-sponsored training · info@atlantisndt.com