Magnetic Particle Inspection (MT) in Savannah, Georgia
Atlantis NDT carries out magnetic particle inspection (MPI, also called mag particle testing) in Savannah, Georgia, searching for surface and near-surface cracks in carbon and low-alloy steel. Typical jobs are welds on terminal cranes and yard equipment, rigging and lifting hardware, ship repair steel, mill machinery and fabricated structures. Technicians travel to your site for the agreed scope. List the parts and welds through the MT inspection quote form and we reply within one business day.
Where magnetic particle testing is used in Savannah
A port that lifts millions of containers a year wears out hooks, pins and welds. Magnetic particle inspection is the quick, visual way to find the fatigue crack that grows from a weld toe or a sharp corner long before the part fails. Savannah's mix of terminals, mills, shipyard work and aerospace support gives the method plenty to do.
- Cranes and container handling: welds on crane booms, portal legs and trolley frames, spreader twist-lock housings, lashing hardware, and the structure that carries the rails under rubber-tired gantries.
- Rigging and lifting gear: hooks, shackles, padeyes, lifting lugs and spreader beams, which are often inspected before a heavy lift or after an overload event.
- Ship repair and marine steel: repair welds on frames and brackets, doubler plates, deck fittings, mooring bitts and rudder or shaft supports on vessels that call for work at the river.
- Paper and process plants: welds on carbon steel vessels and supports, lifting lugs on equipment, roll journals and housings, and structural steel around heavy machinery.
- Fabrication and aerospace support: weldments, ground-support equipment, jacks, work stands and tooling for the aviation cluster, where a cracked fixture can damage far more than itself.
Almost all of this is ferromagnetic steel, which is exactly where magnetic particle inspection works well.
What magnetic particle inspection finds and what it misses
When a ferromagnetic part is magnetized, a crack that interrupts the field forces some of it to leak out of the surface. Fine iron particles applied to the part gather at that leakage and outline the crack. The method is quick, sensitive and light on equipment, but it has firm limits.
- It finds: surface-breaking cracks, laps, seams and slightly subsurface discontinuities in ferromagnetic material such as carbon steel and low-alloy steel, including cracks too fine to see by eye.
- It misses: anything in austenitic stainless steel, aluminum, copper or titanium, because those metals do not carry a magnetic field; and deep flaws, which leak too little field to show at the surface.
- It depends on direction: a crack shows best when it lies across the magnetic field, so each area is examined twice with the field turned about ninety degrees.
- It depends on the surface: thick paint, scale and weld spatter weaken the indication and may need removal at the test area.
If the part is stainless or non-magnetic, liquid penetrant inspection in Savannah is the usual substitute, and if the question is remaining wall, ultrasonic thickness testing is the right tool.
How the technique is applied
Field work in Savannah is mostly done with a handheld electromagnetic yoke, which magnetizes the area between its legs. A yoke is portable, needs only a power point, and leaves no arc burns on the surface, so it suits crane steel, weld toes and lifting gear. Prods can be used on thick sections where a current has to be driven through the part, but they demand caution because they can burn the surface.
- Visible dry or wet particles: colored powder or an aerosol suspension is applied over a contrast paint, which is practical outdoors on structures and welds.
- Fluorescent particles: these glow under UV-A light in a darkened area, which gives higher sensitivity on critical welds and machined parts, and is typical of shop and tent-covered work.
- Field strength check: a pie gauge or field indicator confirms that the magnetic field is adequate and correctly directed before particles go on.
- Demagnetization: parts that will be welded, machined or placed in sensitive service are demagnetized afterward, because a residual field can pull particles and swarf onto surfaces.
Method rules come from ASTM E1444 and ASME Section V Article 7; read our summary of the Article 7 magnetic particle requirements or the magnetic particle testing guide for the detail.
What indications look like on Savannah steel
A crack indication is a sharp, tight, line of particles that follows the defect and is usually well defined against the background. A fatigue crack at a crane weld toe tends to run along the toe, while a hot crack in a repair weld may show across the weld bead or at a crater. Laps and seams in forged lifting hardware show as short lines at the surface, and a rounded smear of particles with a fuzzy edge often points to a subsurface source or a change in section rather than a crack.
Non-relevant indications are a daily reality. Sharp changes in geometry, the edges of welded attachments, magnetic writing left by earlier tests, and tool marks can all hold particles. The technician's job is to tell relevant indications from non-relevant ones, re-examine doubtful areas after light cleaning or demagnetizing, and report only what the procedure and code call for. Confusing the two either wastes repair effort or leaves a real crack in service, which is why Level II judgment and Level III oversight matter more than the equipment.
Weld inspection on crane structure is often repeated at intervals. Comparing today's photographs and sketches with the previous visit shows whether a stopped crack is truly stopped, and a record that is easy to read speeds that comparison.
Codes and acceptance criteria for Savannah work
- ASME Section V Article 7: the examination method, including yoke lifting power, particle and light requirements, and the need for two examinations at roughly right angles.
- ASME Section VIII Division 1 Appendix 6: magnetic particle methods and acceptance for pressure vessel welds.
- ASME B31.3 and B31.1: piping examination requirements and acceptance tables for process and power piping.
- AWS D1.1: structural steel, where magnetic particle examination is a recognized method for surface cracks in fillet and groove welds.
- API 510, 570 and 653: in-service codes for vessels, piping and tanks. The owner's authorized inspector is responsible for the inspection; Atlantis performs the examination and reports each indication.
OSHA 29 CFR 1910.119 expects covered facilities to inspect equipment under good engineering practice, and the state of Georgia, through the Office of Insurance and Safety Fire Commissioner, regulates boilers and pressure vessels. Our job is to deliver crisp, code-referenced crack data to the people who own those decisions.
Who performs the work
Atlantis has no office in Savannah. Technicians are mobilized to your terminal, mill, shipyard or fabrication shop for the agreed scope. They work to a written practice based on ASNT SNT-TC-1A: a Level II technician sets up the yoke, checks the field, applies the particles and interprets what is seen, and an ASNT Level III approves the procedure and reviews the report. Our founder, Anoop Rayavarapu, is ASNT NDT Level III in UT, RT, MT, PT and VT, and the company holds ISO 9001 and ISO 14001 certification. If your contract names an acceptance code, the procedure is written to it, with the lifting-power check, the light levels and the demagnetization requirement stated in advance.
What the magnetic particle report contains
- Component or weld identification, material, location, surface condition and test temperature.
- Procedure number and revision, the code and edition, and the acceptance criteria used.
- Equipment details: yoke or prod unit, calibration or lifting-power check, particle type and lot, UV-A intensity and ambient light readings where fluorescent particles are used.
- Technician name and qualification level, date and weather conditions for outdoor work.
- Each indication described by location, orientation, length and whether it is accepted or rejected, with a sketch or photograph where useful.
- A note on demagnetization and post-test cleaning.
Rejected indications are reported to your representative as found, so repair and re-examination can be planned.
Planning a magnetic particle job in Savannah
- Rain, dew and humidity: wet particle suspensions and paint contrast respond to moisture, and wind or rain on an open wharf can ruin a visible examination, so a tent or windbreak is often arranged.
- Heat: steel in summer sun can exceed the temperature range the particle carrier or the procedure allows, and shaded or cooler working hours keep the method inside its limits.
- Daylight versus darkness: fluorescent work needs a dark area, so a portable enclosure or night-time work may be needed outdoors.
- Terminal access: secure port areas generally require a TWIC card and a safety orientation, and crane or lane operations decide when gear can be taken out of service.
- Coatings: if crane steel is painted for corrosion protection, the owner decides how much coating may be removed at weld areas, and the procedure addresses coatings in advance.
Give us a part list, access method and out-of-service dates, and we plan mobilization to suit; we do not promise a crew arrival time without them.
Before any work starts, a short pre-job conversation settles the practical points: which welds are in scope, whether paint stays or goes, how power is supplied for the yoke, where a tent or dark enclosure can stand, and who signs off on rejected indications. Settling these on paper keeps a crane or yard from sitting idle while someone looks for a power point, and it keeps the report aligned with what the owner actually asked for.
Choosing between MT, PT and UT in Savannah
Use magnetic particle inspection for surface cracking on carbon and low-alloy steel, because it is fast and finds cracks that are tight and shallow. Use penetrant testing on stainless steel, aluminum and other non-magnetic metals, or where particles cannot be applied. Use ultrasonic testing when the concern is wall loss or flaws inside a weld. The MT versus PT comparison sets out the trade-offs, and the national MT service page describes the method in general terms.
The Savannah mix of cranes, mills and marine steel rewards a repeatable record. Photographs of each weld before and after examination, clear sketches of indications and consistent location marks let a later technician confirm whether a repaired weld has stayed sound through another season of heavy lifts. Sending us the previous report with your request lets the examiner start from the same points rather than from scratch.
Training your own magnetic particle technicians
If you maintain cranes or heavy equipment in Savannah, a trained in-house technician can check critical welds more often than visits allow. Atlantis teaches MT Level 1 and MT Level 2 under SNT-TC-1A, and the magnetic particle training overview shows what is covered. Your company certifies its technicians under its own written practice, and we can help you draft it through written practice development. For local scheduling questions see NDT training for Savannah employers.
Frequently asked questions
What is magnetic particle inspection used for in Savannah?
It finds surface and near-surface cracks in carbon and low-alloy steel. In Savannah that includes welds on terminal cranes, rigging and lifting gear, ship repair steel, mill machinery and fabricated structures.
Will magnetic particle testing work on a stainless steel or aluminum part?
No. Austenitic stainless steel, aluminum and other non-magnetic metals do not carry the field the method needs. Liquid penetrant testing is normally used on those materials to find surface-breaking cracks instead.
Do you need to remove paint before MT inspection?
Thin, sound coating can sometimes stay if the procedure allows it, but thick paint, scale or spatter weakens indications. The owner decides how much coating is removed, and the procedure states the limit in advance.
Does Atlantis have a Savannah office or lab for magnetic particle work?
No. Atlantis has no office in Savannah. Technicians are mobilized to your terminal, mill, shipyard or shop, bring portable yokes and materials, and issue a written report for the agreed scope.
Why is each area examined twice in magnetic particle testing?
A crack shows best when it crosses the magnetic field, so the field is applied in two directions about ninety degrees apart. That way cracks running in any direction are detected rather than only one orientation.
Is demagnetization always needed after MT?
Not always. It is required when a residual field could interfere with later welding, machining, instruments or service. The procedure and your specification state when demagnetization and residual field checks apply.
Can fluorescent magnetic particle testing be done outdoors in Savannah?
Yes, with a darkened area. A portable enclosure or night-time work provides the low ambient light and UV-A intensity the examination needs, so planning for light conditions belongs in the job scope.
Who certifies the technicians who perform MT for Atlantis?
Under ASNT SNT-TC-1A the employer qualifies and certifies its own personnel through a written practice. Atlantis technicians are qualified under that company practice, with an ASNT Level III approving procedures and reviewing reports.
Can Atlantis train my crew in magnetic particle testing?
Yes. Atlantis offers MT Level 1 and Level 2 training aligned with SNT-TC-1A, and your company then certifies its technicians through its own written practice after the required training and experience.
Inspection and training around Savannah
- Ultrasonic testing (UT) in Savannah
- Liquid penetrant testing (PT) in Savannah
- Magnetic particle inspection services
MT by industry for Savannah: LNG · Aviation & Aerospace · Pulp & Paper.
MT by job: Magnetic particle weld inspection · Magnetic particle inspection of lifting equipment · Magnetic particle inspection of castings and forgings · Magnetic particle inspection of structural steel and bridges.
Training your own technicians: MT Level 1 training · MT Level 2 training · NDT training for Savannah technicians.
Request an MT inspection quote for Savannah
Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for magnetic particle inspection in Savannah.
Need magnetic particle testing (MT) done, or learned?
Atlantis provides magnetic particle testing (MT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.