Magnetic Particle Inspection (MT) in Portland, Oregon

Atlantis NDT sends magnetic particle technicians to Portland, Oregon, to examine welds, castings, forgings and in-service steel for surface and near-surface cracks. The work covers crane runways and lifting gear, ship repair welds, steel bridge details, fabricated frames and pressure equipment repairs. Examinations follow a written procedure, indications are marked and recorded, and an ASNT NDT Level III reviews the report. Request a Portland magnetic particle quote with the part list, access and governing code.

Where mag particle testing is used around Portland

Most of Portland's heavy steel is ferromagnetic carbon and low-alloy plate, which is exactly what this method suits. On the Willamette River, the Swan Island repair yard works on large vessels in floating drydocks, and crane rails, bollards, hull weld repairs, rudder and shaft support structures and lifting padeyes all produce magnetic particle work. The harbor's terminals handle containers, autos, liquid bulks, grain and break-bulk cargo, so container cranes, ship-to-shore rails, bulk conveyor frames and rail-served loading structures carry fatigue-sensitive welds that are inspected on a regular schedule.

Fabrication shops across the metro area build structural steel, vessels, trailers, heavy equipment frames and plate assemblies. Those shops use magnetic particle inspection for weld toes, root grind-outs, gouged-and-welded repair areas and lifting attachments before parts ship. Owners of cranes, hoists, forklifts and trucks use it to check for fatigue cracks at pin bores, boom welds and frame joints that visual examination alone can miss.

Rail is part of the picture too. The largest container terminal has an on-dock railyard, and rail-served bulk and auto terminals sit along the same river corridor, so rail-mounted equipment, loading arms and trackside steel add to the list of structures whose welds are examined on a schedule. Owners often combine several of these items into one visit so the technician and yoke are used efficiently.

What the method finds and what it misses

Magnetic particle inspection works only on ferromagnetic material: carbon steel, low-alloy steel and martensitic grades. Austenitic stainless steel, aluminum, copper-nickel and titanium are not magnetic, so those parts need a penetrant examination instead. The technician magnetizes the part so that magnetic flux crosses the expected crack direction. A crack interrupts the field and pulls a small leakage field to the surface, which attracts fine iron particles and shows as a sharp line. The method is fast and sensitive to tight surface-breaking cracks, including fatigue cracks, toe cracks, laps and seams, and to some flaws just below the surface.

The depth of sensitivity falls off quickly, so buried flaws are not reliably found. Orientation matters, because a crack lying parallel to the field produces almost no leakage; the code therefore requires two examinations with the field at roughly right angles. Paint, scale and heavy weld spatter weaken indications and have to be dealt with before examination. Sharp geometry changes, such as thread roots and keyways, can create non-relevant indications that the technician has to tell apart from cracks.

Codes and acceptance criteria for MT in Portland

The technique is written to ASME Section V Article 7, and the acceptance criteria come from the construction code. For pressure vessels, ASME Section VIII Division 1 Appendix 6 sets methods and acceptance. For process piping, ASME B31.3 paragraph 344.3 sets the method and Table 341.3.2 sets what is acceptable. For structural steel, AWS D1.1 covers the examination of welds, and AWS D1.5 applies to steel highway bridges. ASTM E709 is the guide to the method and ASTM E1444 is the practice for magnetic particle testing. For equipment repaired in service, the National Board Inspection Code sets the rules for repairs and alterations, and Oregon has adopted the 2023 edition of that code in its 2024 Boiler and Pressure Vessel Specialty Code, effective October 1, 2024. The Oregon Building Codes Division publishes the current code book. If the repair or inspection is covered by API 653 or API 570, the owner's authorized inspector accepts the work and Atlantis provides the NDE results.

How a magnetic particle examination is carried out

In the field, the most common tool is the electromagnetic yoke. Under ASME Section V Article 7, an alternating-current yoke must show a lifting power of at least 10 pounds at the maximum pole spacing used, and a direct-current or permanent-magnet yoke at least 40 pounds. The technician checks the lift on a steel test weight, cleans the weld and an adjacent band of base metal, places the yoke across the weld, applies particles, and then repeats with the yoke rotated about ninety degrees. Prods are used where yokes cannot reach and only where the code allows them, since arcing can burn the surface.

Particles come in two forms. Dry powder in a contrasting color is applied by hand bulb for field welds and works well on warm, dry surfaces. Wet particles in a liquid carrier give a stronger indication on fine cracks; fluorescent wet particles are examined under UV-A light in a darkened area, while visible wet particles can be checked in good white light. In shops, a stationary bench with coil and central conductor circular magnetization is used for small parts and forgings. After examination, parts that will go back into service, be welded or sit near sensitive equipment may need demagnetizing, and the technician checks the residual field with a gauss meter.

Personnel, procedures and oversight

Atlantis has no office in Portland. Technicians are mobilized to your site for the scope you agree. They work under the company's written practice, based on ASNT SNT-TC-1A, in which a Level II technician sets up the equipment, performs the examination and interprets indications, and an ASNT NDT Level III approves the procedure and reviews the report. That Level III is Anoop Rayavarapu, whose ASNT NDT Level III qualification covers UT, RT, MT, PT and VT. We can also work to your own written practice and procedure; if you need help drafting one, see our written practice development service. Atlantis is certified to ISO 9001 and ISO 14001.

Judging indications and what happens after a finding

Every mark that appears is first sorted into relevant or non-relevant. A relevant indication comes from a real discontinuity; a non-relevant one comes from a change in section, a magnetic writing mark or a sharp edge, and the technician proves which it is by cleaning and re-examining, or by changing the magnetizing direction. Relevant indications are then described by shape. Under ASME Section VIII Division 1 Appendix 6, an indication whose length is more than three times its width is a linear indication, and linear indications in a finished weld are generally unacceptable, while rounded indications are judged against size and spacing limits. The report states the criterion used so the reader can follow the decision.

When a crack is found, the usual next step is to mark its ends, grind it out under an agreed repair procedure, and re-examine the ground area to confirm the crack is gone before any weld repair is made. The repaired weld is then examined again by the same method. Keeping that loop on one visit saves a second mobilization to Portland, so we ask for the repair procedure and the welder's availability in advance when the job is likely to produce findings.

What the MT report shows

Planning an MT job in Portland

Portland weather affects magnetic particle work in specific ways. Rain and mist on outdoor steel are a problem for dry powder, which clumps on wet surfaces, and wet suspensions can be diluted. Crews bring shelters and drying equipment when they expect damp conditions, or schedule outdoor work for drier months. Cold mornings do not stop the method, but the carrier liquid and the technician's checks need to remain in the range the procedure allows, and very hot or very cold parts are handled with a procedure written for them. For fluorescent work, the area must be dark enough, so work in a bright yard or drydock often needs a tent or a move indoors.

Plant and yard access also shapes the plan. Marine and terminal sites have their own orientation, badging and hot-work permits, and cranes and elevated structures need lifts or scaffolds in place before the technician arrives. Tell us the surface coating, the weld type and thickness, and the preferred time window, and we plan one trip around them. A short call before the visit settles which areas need paint removed, which need scaffolding, and which can be examined as they stand. Sending photographs of the areas to be examined avoids surprises with insulation, fireproofing or tight access.

Choosing between MT, PT and UT in Portland

If the part is carbon or low-alloy steel and the question is cracks at the surface, magnetic particle testing is usually the quickest and most sensitive answer. If the part is stainless steel, aluminum or a copper-nickel alloy, use liquid penetrant testing in Portland. If the question is wall thickness or internal weld quality, use ultrasonic testing in Portland. The national magnetic particle testing page covers the service in general, and the MT versus PT comparison helps when the choice is not clear.

Atlantis does not perform radiographic testing in the United States; where volumetric examination is needed, ultrasonic examination may be an option if your code and owner agree.

Training MT technicians in Portland

Teams that inspect their own cranes and fabrications can train technicians through MT Level 1 training and MT Level 2 training. Our Portland NDT training page explains how the course, the simulator and the hands-on practical fit your written practice. For background on the Article 7 requirements, read the ASME Section V Article 7 explainer.

Frequently asked questions

What is magnetic particle inspection and when is it used in Portland?

It is a method that finds surface and slightly subsurface cracks in ferromagnetic steel by magnetizing the part and applying fine iron particles. In Portland it is used on crane steel, ship repair welds, fabrications and lifting gear.

Can magnetic particle testing be used on stainless steel or aluminum?

No, because the method needs the part to be strongly magnetic. Austenitic stainless steel, aluminum and copper-nickel are not, so liquid penetrant testing is used instead for surface-breaking flaws on those materials.

When would a Portland job use fluorescent wet particles instead of dry powder?

Dry powder in a contrasting color suits field welds on warm, dry steel. Wet particles, often fluorescent and viewed under UV-A light in a dark area, give a stronger indication on fine cracks and suit shop work or critical welds.

Does Portland rain stop magnetic particle inspection outdoors?

Rain affects dry powder and can dilute wet suspensions, so crews use shelters and dry the surface before testing, or schedule work for drier weather. We discuss the weather plan with you when we agree the scope.

Why does the procedure require two directions of magnetization?

A crack that lies parallel to the magnetic field gives almost no leakage and may not show. Examining twice with the field at roughly right angles lets cracks in any direction produce an indication.

Is demagnetizing required after MT?

Only when a residual field would interfere with later welding, machining, instruments or service. The technician checks the residual field with a meter and demagnetizes the part if the procedure or the owner requires it.

Which codes govern magnetic particle testing of welds in Oregon?

The method comes from ASME Section V Article 7, with acceptance taken from the construction code, such as ASME Section VIII Appendix 6, ASME B31.3 or AWS D1.1. Oregon adopts the National Board Inspection Code for repairs of pressure equipment.

Does Atlantis have an office or technicians stationed in Portland?

No. Atlantis has no office in Portland. Technicians are mobilized to your site for the agreed scope, with travel planned in the quote. We reply to every enquiry within one business day.

Can you examine crane runway welds and lifting lugs?

Yes. Crane runways, padeyes, lifting lugs and fatigue-prone details on carbon steel are common magnetic particle work. Send the drawings or photographs and the load rating documents so the examination matches the code or manufacturer requirement.

Inspection and training around Portland

MT by industry for Portland: Marine & Shipbuilding · Pulp & Paper.

MT by job: Magnetic particle weld inspection · Magnetic particle inspection of lifting equipment · Magnetic particle inspection of castings and forgings · Magnetic particle inspection of structural steel and bridges.

Training your own technicians: MT Level 1 training · MT Level 2 training · NDT training for Portland technicians.

Request an MT inspection quote for Portland

Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for magnetic particle inspection in Portland.

Need magnetic particle testing (MT) done, or learned?

Atlantis provides magnetic particle testing (MT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.