Magnetic Particle Testing (MT) in Fort Worth, Texas
Atlantis NDT mobilizes Level II technicians to Fort Worth sites for magnetic particle testing, the fast surface method for carbon and low-alloy steel. We search weld toes, lifting gear, crane structure and equipment welds for cracks that open to or lie just under the surface, and we judge them against the acceptance criteria of your code. Send the part list and specification through the quote request form and we reply within one business day.
Where mag particle testing is used in Fort Worth
Fort Worth's steel is shaped by freight, flight and fabrication. The city sits on a major freight corridor, and rail-served terminals, intermodal yards and distribution buildings across north Fort Worth run overhead cranes, container-handling gear, steel racking and heavy structural frames. Aerospace plants and their suppliers use fixtures, lifting beams, handling dollies and ground-support equipment where cracks start at welds and holes. Fabrication shops serving energy, construction and transportation produce structural frames, pressure-equipment skids and pipe supports that need final surface inspection before they ship.
The gas-field legacy of the Barnett Shale adds separators, compressor skids, wellhead structures and gathering-line fittings, mostly carbon steel and mostly good MT candidates. Industrial buildings, bridge-related steel and municipal structures add the structural side. In every case the target is the same: a fatigue or fabrication crack that has started at a weld toe, a notch or a threaded section, long before it is visible, and that magnetic particles can reveal.
The physics, and its limits
A magnetized steel part carries flux lines through its volume. A crack that crosses those lines forces some flux out of the surface, and fine iron particles collect over the leakage as a sharp, visible line. This explains both the strengths and the boundaries of the method. Particles show the crack that crosses the field, not the one that runs along it. The method needs ferromagnetic material, so it works on carbon and most low-alloy steels but not on austenitic stainless, aluminum or copper. It is a surface and near-surface method; deeper flaws do not leak enough flux to hold particles.
- Orientation: the part is examined twice with the field turned about ninety degrees, so any crack direction is caught.
- Coating thickness: thick paint spaces the particles from the surface and weakens indications, so coating is removed or the procedure is qualified for it.
- Geometry: sharp threads and section changes can leak flux with no flaw present, which produces non-relevant indications that a Level II must interpret.
For internal flaws and wall loss, ultrasonic testing in Fort Worth is the right companion; for stainless and aluminum parts, use penetrant testing in Fort Worth.
Technique in the field
For most Fort Worth work we use portable electromagnetic yokes. The yoke is placed across the weld with its legs on either side, magnetizing the joint between them. ASME Section V Article 7 expects an AC yoke to lift at least 10 pounds at the maximum pole spacing in use, and a DC or permanent-magnet yoke at least 40 pounds, and the lift is checked with a test weight before work. Particles are applied while the field is on; after the first pass the yoke is rotated for the second pass at roughly right angles.
The choice of particles depends on surface and sensitivity. Dry powder is convenient on rough or warm steel; visible wet particles in a carrier give a cleaner picture on smoother surfaces; fluorescent wet particles give the highest sensitivity under UV-A light, provided the viewing area is dark enough and the light intensity is verified. Central conductor or coil techniques magnetize shafts and bars, and prods can magnetize large welds in locations where arc burns are acceptable. When residual magnetism could affect service or later welding, the part is demagnetized and checked with a field meter. See our complete MT guide and the Article 7 explainer.
Applicable codes and Texas context
MT acceptance depends on the construction code. Pressure vessels under ASME Section VIII Division 1 use Appendix 6; process piping under ASME B31.3 uses paragraph 344.3 and Table 341.3.2; power piping falls under B31.1. Structural steel under AWS D1.1 and bridge steel under AWS D1.5 call for visual and magnetic particle examination with their own acceptance tables, and ASTM E709 and E1444 supply the guide and practice most procedures draw from. Where equipment is in service under API 510, 570 or 653, the owner's authorized inspector decides what to do about a crack; we locate, size and document it.
Texas has a statutory boiler program run by the Department of Licensing and Regulation under Health and Safety Code Chapter 755; repairs and alterations follow the National Board Inspection Code, with commissioned inspectors signing off. MT on a header weld repair or a lifting-lug weld becomes part of that file. For plants under process safety management, OSHA 29 CFR 1910.119(j) makes inspection of equipment, including crack detection, part of the mechanical-integrity program.
Who does the examination
We have no office in Fort Worth, so technicians travel to your site. They are qualified under the Atlantis written practice, which follows ASNT SNT-TC-1A: Level II performs and interprets, and an ASNT Level III approves procedures and reviews reports. Technical oversight rests with Anoop Rayavarapu, ASNT NDT Level III in UT, RT, MT, PT and VT. ISO 9001 and ISO 14001 certificates cover the Atlantis management system. If you need a procedure written to your specification, Level III consulting can supply it.
Reading the particles: real cracks and false alarms
Particles gather wherever flux leaks, and not every leak is a crack. A relevant indication comes from a real discontinuity such as a crack, lap or lack of fusion. Non-relevant indications come from magnetic writing, abrupt thickness changes, thread roots and the boundary between weld metal and base metal. Poorly cleaned surfaces and excess current can leave false indications. A Level II technician will lightly clean, re-magnetize and re-examine a questionable line, then record the decision. The report notes the cause, because an inspector reading it later needs to know whether a line was dismissed for a reason or simply missed.
Surface condition therefore matters before any particles go on. Loose scale, weld spatter and grease are removed; painted surfaces are treated according to the coating limits in the procedure; and in outdoor work the area is dry. On old structures, welds under years of paint may need local coating removal before MT, and the owner should plan the touch-up afterwards.
Typical Fort Worth MT scopes
Most MT requests come from a few situations. A fabricator wants final magnetic particle examination of structural welds before shipment. A distribution or manufacturing site wants periodic inspection of crane hooks, runway welds and lifting beams under its rigging program. A vessel repair crew needs MT of a ground-out excavation before the repair weld and of the finished repair afterwards. A gas facility wants MT on skid-frame welds, nozzle attachments and pipe-support welds during a shutdown. Each job is sized by the number of welds or parts, the access, and the procedure, and each ends with a report your own inspector or engineer can file.
When you ask for a quote, tell us the thickness of any coating, the material grade and whether the work is new construction or in service. Those three details change the technique more than anything else, and they let us bring the right yoke, the right particles and the right surface preparation tools on the first visit.
What the MT report contains
Each report names the component and tag, the code and the procedure with revision, the equipment and its last lifting-power check, the particle type and carrier, the magnetizing technique and field direction, the light levels for fluorescent work, the surface condition and part temperature, and the technician and level. Every indication is located on a sketch, with its type, orientation and length, and is marked relevant or non-relevant and accepted or rejected against the named criteria. If the part was demagnetized, the residual field reading is included, and photographs can support a disputed call.
Planning MT in Fort Worth
Weather decides the method. In a North Texas summer, steel in the sun can be too hot for liquid carriers, which evaporate before the examination is complete; we plan shaded or cooler periods or switch to dry powder where that is allowed. Wind makes dry powder awkward, and a screen or a changed schedule may be needed. Winter mornings can be cold and damp, and moisture on the surface hurts contrast. Fluorescent work needs darkness, which is easy in a building and harder on an open yard, where a portable shroud or after-dark access may be needed.
Access planning matters as much. Facilities at AllianceTexas and elsewhere have badging and orientation steps, rail property requires contractor safety training, and plants require permits for hot work, confined space and height. Cranes and elevated structure need access equipment arranged beforehand; a yoke inspection is only as good as the reach. Share your dates and access constraints with your quote request.
Surface preparation and demagnetization in practice
Good MT starts before the yoke comes out. We remove loose scale, spatter and oil with wire brushes or light grinding, and we check any coating with a thickness gauge against the limit in the procedure. On old rail-yard and plant structure, welds hidden under years of paint often need a clean window at each joint. Afterwards, if the part will be welded, machined or placed near sensitive equipment, we demagnetize it by stepping down an alternating field and confirm the residual reading with a meter, so the magnetism does not deflect a later welding arc or hold chips to a finished surface.
Wet methods leave residue as well, so cleanup is part of the scope: carrier and particles are wiped from the area, and the surface is left ready for coating repair by your crew.
MT, PT or UT for Fort Worth jobs
For a surface crack in carbon steel, MT is fast and sensitive. For stainless, aluminum or any non-magnetic alloy, use penetrant. For depth, wall loss or internal flaws, add ultrasonic examination. The MT versus PT comparison explains the differences in more detail, and the national magnetic particle testing page describes our scope.
Training your own MT technicians
We train candidates in MT Level 1 and MT Level 2, following SNT-TC-1A recommended hours, with online theory and practice questions in the NDT practice tests. Your company certifies its own technicians and runs the practical at your facility. Learn more on the Fort Worth NDT training page.
Frequently asked questions
Do you have an office in Fort Worth?
No. Atlantis has no office in Fort Worth. We mobilize Level II technicians to your site with yokes, particles, light meters and test weights for the agreed magnetic particle scope.
Which metals can be inspected by magnetic particle testing?
Only ferromagnetic metals such as carbon steel, most low-alloy steels and martensitic grades. Austenitic stainless steel, aluminum and copper cannot be magnetized, so they need liquid penetrant testing for surface cracks.
Why do you examine each weld twice?
A crack running parallel to the magnetic field barely disturbs it. Examining with the field turned about ninety degrees, as ASME Section V Article 7 requires, ensures cracks of any direction can be detected.
Can you inspect crane hooks, lugs and handling gear?
Yes. Hooks, shackles, lifting lugs, spreader bars and their attachment welds are routine MT subjects. We examine to your procedure, and the owner or rigging authority decides on any component that shows a crack.
What do fluorescent particles add?
Fluorescent particles under UV-A light show fine cracks more clearly than visible particles. They need a darkened area and checked light levels, which we verify against the procedure before examining.
Does every part need demagnetizing afterwards?
No. Demagnetizing is done when residual magnetism could interfere with service, welding or machining, or when the specification calls for it. The residual field reading is recorded when it is done.
Do you provide API authorized inspectors?
No. Under API 510, 570 and 653 the inspector of record is the one the owner names. Atlantis performs the MT examination and hands over indication data and records for that person to evaluate.
How do I request MT in Fort Worth?
Send the part list, material, code, surface condition, access notes and outage dates through the quote form. We scope the work, set out assumptions and reply within one business day.
Inspection and training around Fort Worth
- Ultrasonic testing (UT) in Fort Worth
- Liquid penetrant testing (PT) in Fort Worth
- Magnetic particle inspection services
- NDT inspection services in Texas
MT by industry for Fort Worth: Aviation & Aerospace · Rail.
MT by job: Magnetic particle weld inspection · Magnetic particle inspection of lifting equipment · Magnetic particle inspection of castings and forgings · Magnetic particle inspection of structural steel and bridges.
Training your own technicians: MT Level 1 training · MT Level 2 training · NDT training for Fort Worth technicians.
Request an MT inspection quote for Fort Worth
Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for magnetic particle inspection in Fort Worth.
Need magnetic particle testing (MT) done, or learned?
Atlantis provides magnetic particle testing (MT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.