Tank Inspection Services in Baton Rouge 2026 — ASNT Level III Led
Atlantis NDT delivers tank inspection services in Baton Rouge. Methods: UT (including PAUT and TOFD), MT, PT and VT, with procedures and reports reviewed by an ASNT NDT Level III. Baton Rouge facilities in the refining, petrochemical & chemical sectors require rigorous tank inspection services. Technicians are certified by their employer to its SNT-TC-1A written practice. Where we work: nationwide. Technicians are mobilised to your site anywhere in the USA; apart from the Houston office there is no local office, so mobilisation is planned and quoted for each job.
In the United States, Atlantis does not perform radiographic testing (RT): industrial radiography is licensed under NRC rules (10 CFR Part 34) or Agreement State rules. Where the code and the owner allow, ultrasonic testing is the volumetric alternative, and an ASNT Level III can review the radiographs and RT procedures of your licensed radiography contractor.
Tank Inspection Services Scope
Tank inspection covers: floor plates and bottom annulus via MFL; shell courses via UT thickness survey; roof, nozzles, and foundation via visual and settlement measurement — all per API 653, with API 650 new-construction alignment and EEMUA 159 guidance where applicable. Atlantis NDT Level III approves every Procedure + signs off final disposition + audit-ready records via Atlantis NDT ERP.
Code + Compliance
Tank Inspection Services per: ASME B&PV Sections V + VIII + IX + XI; ASME B31 piping series; API 510 + 570 + 571 + 579 + 580 + 581 + 653 + 1104 + 1169; ASTM E-series; ISO 17635/17636/17640; AWS D1.1/3.6; IACS Rec-20 marine; NACE MR0175 + MR0103 sour-service.
Free Consultation
Atlantis NDT publishes no pricing — varies by region + scope. Request your free 30-minute consultation. Every job is quoted on request. See also verticals, Baton Rouge ERP, Baton Rouge training, Baton Rouge consulting.
What tank inspection involves
Aboveground storage tank inspection covers the shell, floor, roof and appurtenances, establishing minimum thickness by course, floor condition, settlement, and the resulting inspection intervals under API 653.
Scope of work
- External inspection of shell, roof, appurtenances, foundation and containment
- Ultrasonic shell thickness by course with minimum-required-thickness calculation
- Floor scanning by magnetic flux leakage with ultrasonic prove-up of indications
- Settlement survey and evaluation against API 653 Annex B criteria
- Vacuum box testing of floor welds and, where required, hydrostatic testing after repair
Governing codes
API 653 for inspection, repair, alteration and reconstruction, API 650 as the construction code, API 575 for practice, and API 579 where fitness-for-service assessment is required.
The Baton Rouge asset base
Baton Rouge hosts ExxonMobil's Baton Rouge Refinery — the fourth-largest US refinery at 502,500 bpd — alongside the ExxonMobil Chemical Plant, ExxonMobil Plastics, Dow Plaquemine, Shintech PVC, and Marathon's Cosmar/Marathon Petroleum corridor extending south along the Mississippi River. The Louisiana DEQ and OSHA PSM programmes drive systematic pressure-equipment inspection across hundreds of fired heaters, distillation columns, and ethylene crackers between Baton Rouge and St. James Parish. Hurricane exposure, sub-tropical humidity, and the elevated CUI risk on insulated piping along the Mississippi River corridor create a strong case for digital twin coating-condition tracking and post-event re-inspection automation.
How the work is controlled
Agree personnel qualification, equipment checks, procedure revision and review responsibilities for the examination. Retain those records with the results and coverage limitations.
What you receive
- A report in your required format, with findings located against the component and, where relevant, against a persistent corrosion monitoring location so trends stay continuous between campaigns
- Raw data in the instrument-native format plus an open export, so the dataset outlives any single supplier relationship
- The procedure revision, technician certification state and instrument calibration status applicable at the time of examination
- Where a finding affects continued service, the specific code clause governing the acceptance decision
Related: asset integrity management software · inspection management software · ASNT Level III consulting · digital twin for asset integrity. Request a quote for Baton Rouge.
Part of NDT inspection services in Louisiana and the full range of NDT inspection services from Atlantis NDT.
Tank inspection around Baton Rouge: river terminals, storm season and keeping the API 653 cycle
Storage tank inspection around Baton Rouge serves refinery and chemical tank farms and river terminals along the Mississippi. Atlantis performs the NDE for the owner's API 653 program, including MFL floor scanning, UT shell thickness, vacuum box testing and settlement data, plus post-storm condition checks. Acceptance and the inspection report stay with the owner's API 653 inspector, and Atlantis does not sign as inspector of record.
A river of tankage. The Port of South Louisiana runs along 54 miles of the Mississippi between New Orleans and Baton Rouge and handled 248.1 million short tons in 2023, with chemicals and petroleum products among its cargoes. Terminal operators on this corridor handle many products in tanks that change service often, and every change of service is a point at which API 653 asks for an engineering review of the tank's suitability, including a brittle fracture check where applicable.
Checks after a storm. From June through the end of November, Gulf storms are the main event risk for river tank farms. API 653 sets routine and internal inspection intervals, but most owners' programs add an event-driven inspection after a hurricane or flood. Typical post-storm items are:
- Floating roofs: pontoon compartments for water or product, roof drain function, seal damage and any tilt or hang-up
- Shell: buckling or local deformation of tanks that were near empty when the wind loaded them
- Foundations: washout, ringwall cracking and any shift of a tank that floodwater lifted at low liquid level
- Appurtenances: stairways, platforms, nozzles and secondary containment walls
Recording those checks against the same reference points used in routine inspections lets the owner's inspector separate storm damage from older defects, which also matters when insurers ask for evidence.
Floors on wet ground. A high water table and fine river-delta soils keep the underside of tank bottoms damp, so soil-side corrosion is a common cause of floor thinning there. MFL scanning finds where the plate has thinned from either side, and UT prove-up of each indication gives the depth the API 653 floor calculation needs. Release prevention barriers and cathodic protection change the expected rate, so their condition belongs in the report.
Rules. In Louisiana, federal OSHA enforces process safety management, and a tank inside a covered process falls under that standard's mechanical integrity element. Terminals storing oil above the federal SPCC thresholds must also follow their 40 CFR Part 112 plan, which ties tank integrity testing to an industry standard. A guide to how the NDE supports the owner's inspector is on the API 653 tank NDE support page, and local detail is on API 653 tank inspection in Baton Rouge.
For the services themselves, see aboveground storage tank inspection, MFL floor scanning and, for vacuum box work, leak testing. Atlantis ERP keeps floor maps and shell readings tied to fixed locations so the next campaign can be compared directly. To plan routine or post-storm work, send the tank list, products and access dates through the Baton Rouge tank inspection request.