Pipeline Inspection Services in Dallas 2026 — ASNT Level III Led
Atlantis NDT delivers pipeline inspection services in Dallas. Methods: UT (including PAUT and TOFD), MT, PT and VT, with procedures and reports reviewed by an ASNT NDT Level III. Dallas facilities in the aerospace, defense & manufacturing sectors require rigorous pipeline inspection services. Technicians are certified by their employer to its SNT-TC-1A written practice. Where we work: nationwide. Technicians are mobilised to your site anywhere in the USA; apart from the Houston office there is no local office, so mobilisation is planned and quoted for each job.
In the United States, Atlantis does not perform radiographic testing (RT): industrial radiography is licensed under NRC rules (10 CFR Part 34) or Agreement State rules. Where the code and the owner allow, ultrasonic testing is the volumetric alternative, and an ASNT Level III can review the radiographs and RT procedures of your licensed radiography contractor.
Pipeline Inspection Services Scope
Pipeline inspection covers: girth weld examination by UT, PAUT and RT; wall-loss measurement by UT thickness and corrosion mapping on above-ground sections and at integrity digs; surface-crack examination by MT — all per API 1104, ASME B31.4/B31.8, and 49 CFR 192/195 where applicable. In-line inspection tool runs are made by ILI vendors; excavation is by the dig contractor. Atlantis NDT Level III approves every Procedure + signs off final disposition + audit-ready records via Atlantis NDT ERP.
Code + Compliance
Pipeline Inspection Services per: ASME B&PV Sections V + VIII + IX + XI; ASME B31 piping series; API 510 + 570 + 571 + 579 + 580 + 581 + 653 + 1104 + 1169; ASTM E-series; ISO 17635/17636/17640; AWS D1.1/3.6; IACS Rec-20 marine; NACE MR0175 + MR0103 sour-service.
Free Consultation
Atlantis NDT publishes no pricing — varies by region + scope. Request your free 30-minute consultation. Every job is quoted on request. See also verticals, Dallas ERP, Dallas training, Dallas consulting.
What pipeline inspection involves
Pipeline inspection establishes the condition of a line along its length, combining in-line inspection where the line is piggable with direct assessment where it is not, and verifying both against excavation findings.
Scope of work
- In-line inspection data review and dig prioritisation from MFL, ultrasonic and crack-detection runs
- Guided wave screening of cased crossings and inaccessible sections
- Dig verification with ultrasonic wall measurement and magnetic particle crack examination
- Coating and cathodic protection survey interpretation
- Girth weld examination by automated ultrasonic testing or radiography on new construction
Governing codes
ASME B31.4 and B31.8 for design and operation, B31.8S for integrity management, API 1104 for welding, and the applicable regulator's integrity management rule.
The Dallas asset base
Dallas-Fort Worth is a corporate command centre for the US energy industry, with AT&T, Energy Transfer, Pioneer Natural Resources (now ExxonMobil), and Atmos Energy all coordinating midstream pipeline integrity and downstream operations from the DFW metro. The combination of heavy midstream pipeline coordination (Permian-to-Gulf), aerospace manufacturing, and corporate engineering oversight makes Dallas a natural digital twin adoption hub.
How the work is controlled
Agree personnel qualification, equipment checks, procedure revision and review responsibilities for the examination. Retain those records with the results and coverage limitations.
What you receive
- A report in your required format, with findings located against the component and, where relevant, against a persistent corrosion monitoring location so trends stay continuous between campaigns
- Raw data in the instrument-native format plus an open export, so the dataset outlives any single supplier relationship
- The procedure revision, technician certification state and instrument calibration status applicable at the time of examination
- Where a finding affects continued service, the specific code clause governing the acceptance decision
Related: asset integrity management software · inspection management software · ASNT Level III consulting · digital twin for asset integrity. Request a quote for Dallas.
Part of NDT inspection services in Texas and the full range of NDT inspection services from Atlantis NDT.
Pipeline inspection in North Texas: who regulates the line and what NDE the dig needs
Pipeline inspection around Dallas usually means NDE at integrity digs, on station piping and on new or replaced sections, carried out for an operator whose line falls under the Railroad Commission of Texas or PHMSA. Atlantis sends crews from Houston for ultrasonic, magnetic particle, visual and holiday testing, while the operator's integrity engineers keep the assessment and repair decisions.
Who regulates the line. The Railroad Commission's Pipeline Safety Department regulates intrastate pipelines in Texas, covering gas distribution, gas transmission and hazardous liquid lines, including highly volatile liquids and any line that crosses a navigable waterway. Only some gathering lines are covered: gas gathering is classified under 49 CFR 192.8 and 192.9, and hazardous liquid gathering is regulated in non-rural areas or where it meets the rural criteria in 49 CFR 195.11. On top of Parts 192 and 195, the Commission applies its own rules in 16 TAC Chapter 8 and damage-prevention rules in Chapter 18. Interstate pipelines are PHMSA's. Settle this before the dig, because it decides whose procedures, report format and record retention the NDE must follow.
The local system. The Barnett Shale natural gas field lies beneath Fort Worth, and by 2011 Railroad Commission figures showed about 2,700 wells in Tarrant County alone, none of which can produce without a gathering line. Because so much of that pipe runs through built-up neighborhoods, class location, and so the level of regulation, matters more here than in open country. Dallas is also headquarters to Energy Transfer, a midstream operator, and to Atmos Energy, a gas distribution utility, so integrity, replacement and compliance programs for large systems are planned from the Metroplex.
NDE that a North Texas integrity dig typically calls for:
- A UT thickness grid or corrosion map over the reported metal-loss feature, recorded so it can be matched to the in-line inspection call
- Magnetic particle or ACFM examination of dents, gouges and the long seam for cracking
- Pit-depth and external corrosion measurements with photographs of coating condition
- Holiday testing of new coating before backfill
- Radiography or automated UT of girth welds on replacement pipe to API 1104
What makes dig data usable. A dig report is only useful when it can be lined up with the in-line inspection feature list, the girth weld numbering and the operator's integrity management records. Atlantis reports give location references, technician certification, instrument calibration and the procedure revision used, and the Atlantis ERP keeps those records linked so a regulator's request can be answered years later.
The individual services are described on the holiday testing, ACFM inspection and automated UT pages. New stations and line sections are covered under commissioning inspection, and the full menu is at NDT inspection services. Operators who need a pipeline NDE procedure written or reviewed by an ASNT NDT Level III can use procedure development. To plan digs or a station campaign, send the feature list, locations and target dates through the North Texas pipeline request.