Ultrasonic Testing (UT) and Thickness Inspection in San Antonio, Texas
Atlantis NDT mobilizes Level II ultrasonic technicians to plants, fabrication shops, hangars and rail-served industrial sites in San Antonio for two jobs: ultrasonic thickness testing on tanks, pressure vessels, piping and structural steel, and ultrasonic weld inspection with angle-beam shear-wave probes. Send us the component list, the governing code and the access conditions and we will scope the examination and quote it. Use the quote request form and we reply within one business day.
Where ultrasonic testing is used in San Antonio
San Antonio is a manufacturing, military and logistics city rather than a single-industry refining town, and that mix shapes the UT work. The metro area ranks among the larger manufacturing markets in Texas, with automotive assembly (a full-size truck plant opened south of downtown in 2006 and pulled a ring of stamping, seating and interior suppliers around it), aerospace repair and overhaul, food processing, and energy-related fabrication. Each of these produces steel that wears out in a recognizable way.
At Port San Antonio, the former Kelly Air Force Base, roughly 1,900 acres hold hangars, an industrial airfield, warehousing and an on-site railport served by Union Pacific and BNSF. Hangar structures, crane rails, ground-support equipment, rail spurs, fuel and utility piping and the loading structures at a railport all need periodic wall thickness checks and weld verification. Food and beverage plants add stainless process piping, steam headers and compressed-air receivers, where the question is usually remaining wall on carbon-steel utility lines and weld quality on repairs.
The power side matters too. A large municipal utility serves the city, and gas-fired generation, boiler feedwater and steam piping, and cooling-water lines are classic thickness-survey subjects. South of the city the Eagle Ford play feeds gathering lines, compressor stations, separators and storage tanks, and San Antonio is where many of the fabrication, hauling and service companies for that work operate. Pressure vessels on skids, flare knockout drums and tank shells are routine UT subjects for those operators when they are not in a refinery.
Ultrasonic thickness testing on corroded steel
A thickness survey answers one question: how much wall is left at each point, and how fast is it going? A technician sets up a dual-element probe, which separates transmit and receive crystals so the sound path works on rough, corroded or pitted outer surfaces, and calibrates it on a step block made of the same material as the component. On carbon steel the velocity is close to a standard value, but a step block at the actual thickness range removes the guesswork and shows zero-offset errors before they enter the data.
Readings are taken on a marked grid, usually at the condition monitoring locations (CMLs) set by the owner's inspection plan. The technician watches the A-scan, not only the digital readout, because a gauge that locks onto a laminar indication or doubles on a thin wall will report a plausible but wrong number. Where a surface is scaled, we grind to bright metal over a small footprint, apply couplant and record whether the reading came from clean metal or a prepared spot. For hot lines, high-temperature probes and couplant are used and the reading is corrected for temperature using the procedure's correction factors.
Method background sits in ASME Section V, Article 5 for ultrasonic examination of materials, ASTM E797 for contact pulse-echo thickness measurement, and our own guide to ultrasonic thickness measurement requirements. If you want the national explanation first, start at ultrasonic testing services.
Ultrasonic weld examination with angle beams
Weld inspection is a different job from thickness gauging. A shear-wave angle-beam probe, commonly 45, 60 or 70 degrees, is scanned beside the weld so the sound enters the joint at an angle that suits the bevel. Before scanning, the technician builds a reference level, often a distance-amplitude correction curve, from side-drilled holes in a calibration block of the same acoustic character as the part. Indications are then compared with that reference to decide whether a reflector is a planar flaw such as lack of fusion or a crack, or a rounded one such as slag.
In San Antonio this applies to fabricated structural steel for buildings and bridges built to AWS D1.1 or D1.5, to pressure-vessel and piping repairs, and to ladder, platform and crane structure repairs at industrial plants. Where a code allows UT in place of radiography on a production weld, the owner, the engineer and the authorized inspector agree the substitution before the job. See the construction code for acceptance, and see our ultrasonic testing guide for the technique overview.
What ultrasonic testing finds and what it misses
UT is the volumetric method of the conventional set: it reads through the wall, not only the surface. It finds wall loss from corrosion and erosion, laminations in plate, and internal weld flaws oriented across the sound beam. It does not replace surface methods for fine surface cracks, and its reliability falls when the surface is rough, painted thickly without removal, or when the grain structure scatters the beam, as in cast and austenitic material.
- Couplant and contact: sound will not cross an air gap. Scaled, flaking or heavily pitted surfaces need preparation before readings mean anything.
- Geometry: weld crowns, nozzles and tight radii limit probe positions and can hide zones from the beam.
- Orientation: a flaw parallel to the sound beam reflects little energy, so weld scans use more than one angle and scan direction.
- Temperature: velocity changes in hot steel, so readings on hot lines are corrected rather than accepted at face value.
When the question is a surface-breaking crack at a weld toe, the right tool is usually magnetic particle testing in San Antonio on carbon steel or penetrant testing in San Antonio on stainless and non-ferrous parts, with UT used to size or confirm.
Codes, acceptance and the Texas framework
The code that governs a job decides the procedure and the acceptance criteria. For fixed equipment, API 510 covers pressure vessels, API 570 covers piping and API 653 covers aboveground storage tanks; in each case the owner's authorized inspector is responsible for the inspection and Atlantis supplies the examination data, such as thickness at CMLs, for that person to evaluate. New construction and repair follow ASME Section VIII Division 1 (Appendix 12 for ultrasonic examination of welds) or ASME B31.3 (paragraph 344.6 for UT, with acceptance in Table 341.3.2). Structural steel follows AWS D1.1, including its ultrasonic provisions for groove welds, and bridge steel follows AWS D1.5. Pipeline girth welds fall under API 1104.
Texas administers its boiler law through the Texas Department of Licensing and Regulation under Chapter 755 of the Health and Safety Code. That program covers power, heating and process steam boilers, assigns inspection intervals by the ASME code the boiler was built to, and expects inspections by TDLR or an authorized inspection agency. If your San Antonio plant has registered boilers, the UT data we collect, such as drum, header and tube-stub thickness, supports the inspector's certificate decision; it does not replace the commissioned inspector. Process safety management under OSHA 29 CFR 1910.119(j) adds the mechanical-integrity duty to inspect and test equipment under recognized and generally accepted good engineering practice, and pipeline operators in Texas work under the federal PHMSA rules in 49 CFR Parts 192 and 195, administered for intrastate lines by the Railroad Commission of Texas.
Who does the work
Atlantis has no office in San Antonio. Technicians travel to your site for the agreed scope. They are qualified under the Atlantis written practice, which is written to ASNT SNT-TC-1A: a Level II technician sets up and calibrates the instrument, performs the examination and interprets the results, and an ASNT Level III approves the procedure and reviews the report. The company was founded by Anoop Rayavarapu, ASNT NDT Level III in UT, RT, MT, PT and VT. We hold ISO 9001 and ISO 14001 certification for the company management system. If your plant already has a written practice and procedure, we work to those; if you do not, the Level III consulting service can write them, and see written practice development.
What the UT report contains
A usable UT record lets another Level II repeat the examination. Each report lists the component identification and drawing or tag number, the code and the procedure with its revision, the instrument, probes, wedges and calibration blocks with calibration dates, the technician and certification level, the surface condition and temperature, and the couplant used. Thickness work includes the grid or CML layout, the nominal and measured values, the minimum required wall if the owner supplies it, and a note where a reading was blocked or doubtful. Weld work includes the scan plan, the reference level, each recordable indication with location, length, amplitude and depth, and an accept or reject decision against the named criteria. Sketches mark the indications on the weld map so the repair crew can find them.
Planning a UT job in San Antonio
South Texas heat is the first planning item. Steel in direct sun in summer can run far above the temperature where standard probes and couplant behave, so we schedule shaded or early-shift work where we can, and bring high-temperature couplant for lines that are hot in service. Summer humidity is moderate, but dust and wind-blown grit on outdoor tanks and rack piping affect surface preparation, and winter mornings occasionally fall near freezing, which stiffens couplant and slows contact work. Rain stops outdoor examination because water films on the surface mask conditions.
Access matters as much as weather. Plants on the Interstate 35 and Interstate 10 corridors and the loop roads generally have badging and safety orientation; plan for that and for site-specific permits for confined space, hot work and work at height. Port San Antonio is an industrial airfield, so work near taxiways and hangar aprons follows airfield access rules set by the site operator. For outage-driven work, tell us the shutdown window and the scaffold or rope-free access plan early, so the scope is sized to what can actually be reached.
UT, MT or PT for your San Antonio job
Choose by the question. If you need remaining wall, a corrosion survey or an internal weld flaw, UT is the answer. If you need a surface or near-surface crack at a weld toe or a fillet on carbon steel, magnetic particle examination is faster and more sensitive on the surface. If the material is stainless, aluminum or any non-magnetic alloy and the concern is a surface-breaking flaw, liquid penetrant is the method. Many turnaround scopes use all three on one vessel: UT for remaining wall, MT on carbon-steel nozzle welds, PT on stainless internals. Compare them in MT versus PT or ask us to sequence them for you.
Training your own technicians
If you would rather build in-house capability, our UT Level 1 and UT Level 2 courses follow the SNT-TC-1A recommended hours, and theory can be taken online with the UT practical simulator for hands-on practice. Hands-on practical examinations happen at the employer's facility under the employer's written practice, because under SNT-TC-1A the employer certifies its own personnel. See NDT training for San Antonio and check the SNT-TC-1A eligibility tool to see what experience hours a candidate needs.
Frequently asked questions
Do you have an office or lab in San Antonio?
No. Atlantis has no office in San Antonio. Level II technicians travel to your site for the agreed scope, working under the Atlantis written practice to ASNT SNT-TC-1A with Level III approval of procedures and review of the reports.
What ultrasonic services can you perform in San Antonio?
We perform contact ultrasonic thickness testing on tanks, vessels, piping and structural steel, and angle-beam shear-wave examination of welds. We do not offer radiographic testing in the United States or any advanced ultrasonic technique.
Can ultrasonic testing replace radiography on my welds?
Occasionally, and only when both the construction code and the owner permit it. ASME B31.3, API 1104, AWS D1.1 and ASME Section VIII each contain different provisions, so the owner, the engineer and the authorized inspector agree the substitution before any work begins.
How are thickness readings kept accurate on pitted pipe?
We use dual-element probes, calibrate on a step block of the same material, read the A-scan rather than only the digital value, and prepare the surface to bright metal where needed. Readings taken on prepared and unprepared spots are noted separately.
Do you work on API 510, 570 or 653 equipment?
Yes, as the examination provider. The owner's authorized inspector remains responsible for the inspection and the fitness decision, and we deliver the thickness and weld data, procedures and calibration records that inspector needs to make it.
How does Texas boiler law affect UT work at my plant?
Texas regulates boilers through the Department of Licensing and Regulation under Health and Safety Code Chapter 755, with commissioned inspectors from the state or an insurer. Our UT data supports their decisions; it does not replace the commissioned inspection.
How hot can the steel be for ultrasonic readings?
Standard probes and couplant have limits, so hot lines need high-temperature probes and couplant plus a temperature correction. We confirm the surface temperature in the procedure before the job and may need the line cooled or the reading taken at a different location.
How do I get a quote for UT in San Antonio?
Send the component list, code, thickness range, surface condition, access notes and shutdown window through the quote form. We scope the examination, state the assumptions and reply within one business day.
Can you train our own staff in ultrasonic testing?
Yes. Level 1 and Level 2 UT courses follow SNT-TC-1A recommended hours, with online theory and simulator practice. Your company certifies its personnel under its written practice; Atlantis supports the training and examination records.
Inspection and training around San Antonio
- Magnetic particle inspection (MT) in San Antonio
- Liquid penetrant testing (PT) in San Antonio
- Ultrasonic inspection services
- NDT inspection services in Texas
UT by industry for San Antonio: Aviation & Aerospace · Oilfield & Drilling.
UT by job: Ultrasonic pipe thickness testing · Ultrasonic weld inspection · Ultrasonic boiler tube thickness testing · Ultrasonic testing of castings and forgings.
Training your own technicians: UT Level 1 training · UT Level 2 training · NDT training for San Antonio technicians.
Request an UT inspection quote for San Antonio
Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for ultrasonic testing in San Antonio.
Need ultrasonic testing (UT) done, or learned?
Atlantis provides ultrasonic testing (UT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.