Radiographic Testing Services in Jacksonville

Professional Radiographic Testing (RT) inspection services in Jacksonville. ASNT Level II & III certified inspectors specializing in weld inspection, casting evaluation, pipe inspection and volumetric flaw detection for oil & gas, aerospace, power generation, and manufacturing industries.

Why Choose Atlantis NDT for RT in Jacksonville?

Atlantis NDT provides certified Radiographic Testing inspectors in Jacksonville with expertise in API 510/570/653 compliance, ASME Section V procedures, and AWS D1.1 weld inspection. Contact us for a free quote.

What Atlantis provides in Jacksonville is set out in full on the radiographic testing services page — film and digital radiography with the source logistics, exclusion zones and permanent image records a contract requires.

What Radiographic Testing (RT) actually detects

Radiography passes X-ray or gamma radiation through the component onto film or a digital detector, producing a permanent volumetric record. It remains the reference method where a reviewable image of the through-wall condition is required.

  • Porosity, slag inclusions and volumetric weld defects
  • Incomplete penetration and lack of fusion
  • Cracks favourably oriented to the beam
  • Wall loss and internal deposits under insulation via profile radiography
  • Corrosion in small-bore piping without insulation removal

Codes and acceptance criteria applied

Examinations are performed to written procedures qualified against ASME Section V Article 2, ASME Section VIII Division 1 UW-51/UW-52, AWS D1.1 Section 6, API 1104 and ISO 17636. Acceptance criteria are taken from the construction or in-service code governing the item — ASME Section VIII for pressure vessels, ASME B31.3 for process piping, API 510, API 570 and API 653 for in-service equipment, and AWS D1.1 for structural steel.

How the examination is controlled in Jacksonville

Agree personnel qualification, equipment checks, procedure revision and review responsibilities for the examination. Retain those records with the results and coverage limitations.

Reporting and follow-up

Results are issued in the client's required format with indications located against the component and, where relevant, against a corrosion monitoring location so thickness trends stay continuous between campaigns. Findings can be delivered into the client's own maintenance system, or onto a 3D asset model where remaining life and risk-based inspection ranking update as new data arrives.

Related: Radiographic Testing (RT) overview · inspection management software · ASNT Level III consulting · NDT training and certification · request a quote for Jacksonville.