Radiographic Testing in Detroit, Michigan: What Atlantis Offers

If you were searching for radiographic testing in Detroit, the direct answer is that Atlantis NDT does not perform radiographic testing in the United States. Industrial radiography is a licensed activity under Nuclear Regulatory Commission rules in 10 CFR Part 34 or the equivalent rules of an Agreement State, and it is not a service Atlantis provides here. This page explains what Atlantis does provide to Detroit customers who would otherwise reach for radiography.

UT as a volumetric alternative in Detroit

For many weld questions the real need is to see inside the weld, and ultrasonic examination can do that where the construction code and the owner permit it. ASME B31.3 and API 1104 contain provisions for ultrasonic examination of production welds. AWS D1.1 sets its own acceptance criteria for ultrasonic examination of groove welds on structural steel. ASME Section VIII allows ultrasonic examination in place of radiography only under specific conditions. Because substitution is never automatic, it is settled with the owner, the engineer and, for code work, the authorized inspector before the job begins, and the procedure is written to the governing code.

Technicians are mobilized to Detroit sites, and Atlantis has no office in the city. Read about ultrasonic testing in Detroit, or send your weld details and we will tell you whether UT is likely to satisfy your specification.

ASNT Level III radiography services without a radiation licence

Looking at radiographic evidence does not need a source license, because no exposure is made. Atlantis can review radiographs, film or digital images, and the technique sheets behind them, against ASME Section V Article 2 and the construction code. A second read on a disputed indication is a typical Detroit request, especially on castings, fabricated weldments and plant piping where a supplier and a buyer disagree about an image. Atlantis can also review an RT contractor's procedure and written practice before work starts, checking technique, sensitivity, image quality indicators and personnel qualification records.

This work is led by ASNT NDT Level III personnel, including our founder Anoop Rayavarapu, ASNT NDT Level III in UT, RT, MT, PT and VT. Atlantis does not name or recommend radiography contractors, because the owner selects and contracts the licensed company directly.

Where the question arises in Detroit

Radiography questions in metro Detroit come up on cast and fabricated automotive tooling, steel mill weld repairs, refinery and utility piping, and pressure equipment shipped in from fabricators. The owner holds the code, and the acceptance decision stays with the owner or the inspector of record. Michigan boilers and pressure vessels are regulated by the Boiler Division within the state licensing department, so image records and procedures that are complete and consistent help at review. A second Level III reading can catch an interpretation problem early.

Training in radiography theory

Atlantis teaches a theory course for staff who want to read and judge radiographs: RT Level 2 course. It covers principles, image quality and interpretation following the SNT-TC-1A recommended practice. It is not radiation safety training and does not replace a radiographer license, which is a separate legal requirement. The Detroit NDT training page explains enrollment.

Other Atlantis inspection in Detroit

For cracks and wall loss, Atlantis supplies magnetic particle testing, liquid penetrant testing and ultrasonic thickness testing. See the Michigan inspection hub for the full range, and Level III consulting for procedure and report review.

Frequently asked questions

Is radiographic testing available from Atlantis in Detroit?

No. Atlantis does not perform radiographic testing in the United States because industrial radiography is a licensed activity. What Detroit customers can get is ultrasonic testing, an ASNT Level III second read of existing radiographs, and RT theory teaching.

Can ultrasonic testing replace radiography on a Detroit weld?

Sometimes, where the construction code and the owner allow it. ASME B31.3, API 1104 and AWS D1.1 contain ultrasonic provisions, and ASME Section VIII allows it only under specific conditions. Approval comes from the owner, engineer and authorized inspector.

Can you give a second opinion on radiographs from another company?

Yes. An ASNT Level III can review film or digital images and technique sheets against ASME Section V Article 2 and the construction code, and give an independent read on any disputed indication.

Can you review a radiography contractor's written practice?

Yes. A Level III review checks the procedure, the technique sheets and the written practice for personnel qualification against the code, so gaps are found before the contractor starts work.

Do you teach radiographic interpretation?

Atlantis teaches a Level 2 RT theory course under SNT-TC-1A. It is separate from radiation safety training and from radiographer licensing, which are handled by the licensed radiography employer.

Inspection and training around Detroit

Training your own technicians: UT Level 1 training · UT Level 2 training · NDT training for Detroit technicians.

Need a weld examined in Detroit?

Send the drawing or weld list, the material and thickness, and the code you work to. We will tell you whether ultrasonic testing can be used in place of radiography for that work, or quote a Level III review of radiographs you already have. Ask about UT or a radiograph review for Detroit.