Magnetic Particle Inspection (MT) in Pascagoula, Mississippi
Atlantis NDT mobilizes Level II technicians to Pascagoula, Mississippi for magnetic particle inspection of carbon and low-alloy steel. The usual targets are structural and hull welds, lifting gear and crane steel, repaired areas on pressure equipment, and attachment welds on tanks and vessels along the river and Bayou Casotte. Tell us the part, the code and the surface condition, and request an MT quote for Pascagoula.
Steel, ships and refineries: where MT fits in Pascagoula
The Pascagoula River shipyard has built Navy surface ships since the 1930s, and the city still lives on heavy steel fabrication. Add a petroleum refinery, an LNG terminal and a chemical plant on Bayou Casotte, plus marine fabrication yards and ten public port terminals, and you have a large inventory of ferromagnetic structure that must be kept free of cracks.
In fabrication, MT is applied to fillet welds that attach stiffeners, foundations and machinery seats, to the root and toe areas of groove welds on thick plate, and to areas that were gouged or ground during rework. Lifting appliances such as crane hooks, shackles, padeyes, trunnions and spreader beams are inspected periodically because a failure is catastrophic. In the plants, MT finds cracks in nozzle and support-lug welds, structural steel pipe racks, flare and stack supports, and the pins and welds of loading equipment on docks.
Tank farms in the port use carbon steel construction, and shell-to-bottom welds and nozzle repairs are typical MT locations. See the national magnetic particle testing page for the general service description.
What MT finds and where it fails
The method magnetizes the steel, and a crack disturbs the field so that fine iron particles collect over it. It therefore requires ferromagnetic material. Carbon steel and most low-alloy steels qualify; austenitic stainless, aluminum, bronze and nickel alloys do not, and those materials need liquid penetrant testing. Duplex stainless grades behave differently from austenitic ones and must be checked individually before a method is chosen.
MT shows surface-breaking flaws and those just beneath the surface; sensitivity falls off rapidly with depth. A crack parallel to the field may not show, so two field directions are used. Surface roughness, paint thickness and weld spatter all reduce sensitivity. Sharp geometry can create non-relevant indications that look like cracks, and judging them is a skill built through experience with real welds. For buried flaws and wall loss, ultrasonic testing is used instead, as described on the Pascagoula UT page.
Governing codes and Mississippi requirements
ASME Section V, Article 7 defines how magnetic particle examination is done, and ASTM E1444 and E709 provide practice and guide references. ASME B31.3 invokes magnetic particle examination in paragraph 344.3 with accept and reject limits in Table 341.3.2. ASME Section VIII Division 1 Mandatory Appendix 6 covers MT methods and acceptance for pressure vessels. AWS D1.1 sets surface discontinuity limits for structural welds, and shipbuilding contracts typically add their own acceptance criteria that take precedence on the job.
For in-service equipment, API 510, API 570 and API 653 place responsibility on the owner's authorized inspector, and OSHA's process safety management standard in 29 CFR 1910.119 requires mechanical integrity inspection based on recognized good practice. Atlantis performs the MT examination and gives the findings to that inspector.
Mississippi's boiler and pressure vessel program is run by the Boiler and Pressure Vessel Safety Division of the State Department of Health under the 1974 Boiler and Pressure Vessel Safety Act. When a covered vessel is repaired, MT of the weld area can be part of the repair record, so ask your inspector early what documentation the work needs.
Technique in the field
For most field work the technician uses an electromagnetic yoke. ASME Section V sets minimum lifting force for yokes, so each yoke is tested with a weight at the pole spacing in use. Prods are used on thicker sections where the code allows them, taking care to avoid arc burns. Each examination area is covered with the field in two directions roughly at right angles.
Dry powder works on hot or rough surfaces, and is often used outdoors in wind with a blower or applicator. Wet particles, sprayed from an aerosol or a bath, give a finer indication. Fluorescent particles need ultraviolet light and a dark area, which inside hull tanks is easier than outdoors. A field indicator or a quantitative device shows that the field strength is adequate. When visible particles are used on bare steel, a thin white contrast paint is applied first.
Indications are marked and recorded, then compared with the acceptance table. Where the next operation is welding or precision machining, a gauss meter confirms that residual magnetism has been reduced to an acceptable level. Surfaces are cleaned afterward, since leftover particles can interfere with coatings.
Heavy plate, repairs and the cracks MT is asked to find
Thick plate used in warship and offshore construction is welded with high heat input and preheat controls, and the cracks of greatest concern are hydrogen-assisted cold cracks, which can appear in the heat-affected zone hours or days after the weld cools. Procedures for these joints often require a delay before final examination, and MT is run on the finished weld and on the surrounding plate after that delay. Lamellar tearing in the base plate beneath a restrained joint can also reach the surface near the toe, where magnetic particles show it.
Repairs are another large source of MT work. A discontinuity found by another method is ground out, and the cavity is examined with magnetic particles to prove that the crack is completely removed before welding. After welding, the same area is examined again. Temporary attachments, such as lifting lugs and alignment cleats, leave scars when they are cut and ground off, and those areas are checked for cracking. Arc strikes outside the weld zone can form hard, brittle spots that crack in service, and MT is a quick way to find them in a walk-through of a completed structure.
Lifting equipment and periodic inspection programs
A port and shipyard town runs a great deal of lifting gear, and owners usually have a periodic program for it. Magnetic particle examination is a normal part of that program for load-bearing welds and for forged or cast components such as hooks, shackles and swivels. Cracks in these items grow under cyclic loading and can fail without warning, so the practical goal is to find them while they are still small. Technicians clean the surface, magnetize the area in two directions and examine fillet welds, pin bosses, bolt holes and sharp radii, with particular attention to the root of threads and to areas of previous repair.
Lifting appliances are often subject to rules from the owner, the insurer or OSHA. We examine to the procedure and acceptance criteria the owner specifies, and we report the results for the person responsible for the equipment to decide on repair or retirement. We do not make the decision to return a lifting device to service, which belongs to the owner and the competent person on site.
Surface preparation and typical indications
Gulf Coast steel arrives with mill scale, shop primer, salt deposits and rust. Magnetic particles need a clean path to the metal, so preparation by grinding, wire brushing or light blasting is normal, and oils and greases are removed with solvent. Weld spatter and heavy ripples are removed where they hide indications. Where the owner wants the coating retained, a procedure may be proven on a sample with the same coating thickness.
Common relevant indications are linear lines at weld toes, transverse cracks across weld faces, and short, tight lines at starts and stops. Non-relevant indications appear where two materials meet, at sharp changes of section, or along the edge of a heavy grind. The technician examines the area again after light cleaning to see whether the indication returns and, if doubt remains, confirms with another method before reporting a rejection.
Who does the work
MT is performed by technicians qualified through the Atlantis written practice, which follows ASNT SNT-TC-1A. A Level II technician sets up, examines and interprets. An ASNT Level III approves technique sheets and reviews reports. The Level III at Atlantis is Anoop Rayavarapu, ASNT NDT Level III in UT, RT, MT, PT and VT.
The company keeps no office in Pascagoula. Crews are mobilized to your shipyard, plant or terminal with their equipment for the agreed scope. Under SNT-TC-1A each employer certifies its own technicians, so people on your payroll are certified by your program. If you need help setting that up, see our Level III consulting and written practice development pages.
Reporting
An MT report lists the component, drawing and code, the technique used, particle type and color, light levels, yoke identification and the date of its last verification. It names the technician and level. Each indication is described by location, length and orientation, with an accept or reject statement against the named criteria and a sketch or photograph.
When a weld is ground out and re-examined, both examinations appear in the record, so the history of the repair is visible. Reports are reviewed by the Level III before issue, and electronic copies can be organized by component number to match the owner's records.
Preparing for MT in Pascagoula
Coastal humidity and salt air flash-rust cleaned steel quickly, so prepare and examine in the same shift when possible. Hot summer steel suits dry particles better than a wet bath, and ultraviolet inspection needs shade or an enclosure in daylight. In winter, an occasional freeze means checking that the surface and materials are within the procedure's limits. Hurricane season, from June to November, can stop shipyard and terminal work with little notice.
Industrial sites here require orientation, badging and, for confined spaces and hot work, permits. Shipyard areas may carry additional security rules. Power for the yoke, lighting and a staging area should be arranged ahead of time. Our readings on vessels support the owner's own maintenance decisions; Atlantis is still in the process of obtaining class approval (UR Z17, with DNV, Lloyd's Register and ABS) for thickness measurement, so class-credited gauging requires an approved firm.
MT, PT or UT for your Pascagoula job
Choose MT for fast detection of surface cracks in carbon steel. Choose PT where the metal is stainless steel, aluminum or another non-magnetic alloy. Choose UT for internal flaws and thickness. A single repair may use all three methods in sequence.
See the MT versus PT comparison and the Article 7 explanation for detail, and the Mississippi inspection services page for the statewide picture.
Training MT staff
If you prefer your own certified technicians, we offer MT Level 1 training and MT Level 2 training. The Pascagoula training page covers how courses are delivered to local employers, and the practice tests help candidates prepare.
Frequently asked questions
What can magnetic particle inspection find on shipyard steel in Pascagoula?
It finds surface and slightly subsurface cracks, such as weld toe cracks, arc strikes, laps and grinding cracks, on carbon and low-alloy steel. It does not work on non-magnetic metals or find deep internal flaws.
Can MT be used on stainless steel or aluminum?
Not on austenitic stainless steel or aluminum, because they are not magnetic. Liquid penetrant testing is used for those metals. Duplex grades need to be checked individually before a method is chosen.
Which codes govern MT for pressure equipment?
ASME Section V Article 7 sets the method. Acceptance comes from the construction code, such as ASME B31.3 Table 341.3.2 or ASME Section VIII Division 1 Appendix 6. Structural work typically uses AWS D1.1.
Why are two field directions used?
A crack shows best when it lies across the magnetic field, and may not show if it runs parallel. Examining each area with the field in two roughly perpendicular directions catches cracks in any orientation.
Do you perform MT on vessels for class surveys?
Atlantis can examine welds on a vessel for the owner's own decisions. It is still obtaining class approval, so examinations that must be credited to a class survey need a firm that the society has approved.
Do you have a team or office in Pascagoula?
No. Atlantis has no office in Pascagoula. Technicians travel to your site for the agreed scope, and we plan site orientation, badging and permit requirements with you before mobilizing.
What does a Level III do on an MT job?
The ASNT Level III approves the written technique and reviews the report before it is issued. The Level II technician performs the examination and interprets the indications against the acceptance criteria.
Does residual magnetism need to be removed?
Often yes. Remaining magnetism can disturb welding arcs, attract steel debris or affect instruments, so the part is demagnetized and checked with a field meter when later operations could be affected.
What should I include in a request for an MT quote?
Send the component list, drawings, governing code, material, surface condition, temperature, access and site rules. We use these details to define the technique and prepare the scope for your quotation.
Inspection and training around Pascagoula
- Ultrasonic testing (UT) in Pascagoula
- Liquid penetrant testing (PT) in Pascagoula
- Magnetic particle inspection services
- NDT inspection services in Mississippi
MT by industry for Pascagoula: Offshore · Marine & Shipbuilding.
MT by job: Magnetic particle weld inspection · Magnetic particle inspection of lifting equipment · Magnetic particle inspection of castings and forgings · Magnetic particle inspection of structural steel and bridges.
Training your own technicians: MT Level 1 training · MT Level 2 training · NDT training for Pascagoula technicians.
Request an MT inspection quote for Pascagoula
Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for magnetic particle inspection in Pascagoula.
Need magnetic particle testing (MT) done, or learned?
Atlantis provides magnetic particle testing (MT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.