Magnetic Particle Inspection (MT) in Greenville, South Carolina

Atlantis NDT performs magnetic particle inspection (MPI) in Greenville, South Carolina, examining carbon and low-alloy steel for surface and slightly subsurface cracks. Typical jobs include welds on fabricated equipment, press and machine frames, crane runways and hooks, shafts, gears and forgings. Technicians are mobilized to your plant. Send the part or weld list through the MT inspection quote form and we reply within one business day.

Where magnetic particle testing is used in Greenville

The Upstate makes things out of steel, and things that are made and run hard crack. Greenville has a large gas turbine assembly plant, automotive and tire plants with stamping and molding equipment, bearing and gear producers, and engineered-materials makers whose lines run on heavy frames and shafts. Military and commercial aircraft work at the former Donaldson air base adds tooling and ground equipment. The I-85 corridor connects all of this to a rail-served inland port at Greer, whose cranes and rail-mounted equipment are steel structures in their own right.

What magnetic particle testing finds and what it misses

MT applies to ferromagnetic metals: carbon steel, low-alloy steel and martensitic or ferritic stainless grades. Austenitic stainless, aluminum, brass and titanium are not magnetic, so those parts need a different surface method. When a magnetic field passes through a sound part, it stays inside the metal; at a crack that crosses the field, the lines leak out and attract fine iron particles, which pile up along the crack and make it visible. Surface-breaking cracks give crisp indications, and very shallow subsurface flaws on smooth parts can show as softer, broader lines.

The method has limits. It gives no depth, so a crack's severity may need ultrasonic or grinding follow-up. It does not find flaws more than a short distance beneath the surface. Coatings and scale hold the particles away from the metal. And since cracks parallel to the field produce no flux leakage, each area is examined twice with the field rotated about ninety degrees, so any crack direction is covered.

Codes and acceptance criteria

ASME Section V Article 7 defines how MT is performed, covering equipment, particle materials, field strength, lighting and documentation. ASTM E1444 is the common practice standard and ASTM E709 the guide that explains the method. Acceptance comes from the construction code: ASME Section VIII Division 1 sets MT methods and acceptance in Mandatory Appendix 6, ASME B31.3 addresses magnetic particle examination at paragraph 344.3 with limits in Table 341.3.2, ASME B31.1 applies to power piping, and AWS D1.1 and D1.5 cover welded structures and bridges. In many Upstate shops, the customer's own drawing note or purchase specification adds extra requirements, such as fluorescent particles or a maximum background level, and these take precedence in the procedure.

South Carolina regulates boilers and pressure vessels under the Boiler and Pressure Vessel Safety Act in Title 41, Chapter 14, administered by the Department of Labor, Licensing and Regulation. The National Board Inspection Code governs repairs and alterations, and weld repairs normally call for MT or PT of the excavation and finished weld. In service, owners operating under API 510, 570 or 653 depend on their authorized inspector to accept the repair; Atlantis supplies the examination and the record.

Technique: yokes, prods and particles

Most field work uses a handheld electromagnetic yoke. The code requires an AC yoke to lift at least 10 pounds at the largest pole spacing used, and a DC or permanent-magnet yoke to lift at least 40 pounds; the technician checks lifting power with a test weight on a schedule. The poles are placed on both sides of the weld, particles are applied dry or in a liquid suspension while the field is on, and the technician looks for lines of particles that gather at a discontinuity. After the first pass the yoke is turned about ninety degrees and the examination repeated.

Contact prods pass current into the part and reach inside corners the yoke cannot, but they can burn the surface, so many specifications limit or prohibit them. Visible particles in a contrast color are the standard for field work. Wet fluorescent particles give higher sensitivity and are observed under UV-A light in a darkened enclosure; they are common on shafts, gears and critical machined parts. After examination, the technician checks residual magnetism and demagnetizes the part if leftover fields would disturb welding, machining or service.

Common findings in Upstate manufacturing steel

In fabricated structures, MT frequently finds toe cracks and crater cracks at weld terminations. In heavy sections welded without adequate preheat, hydrogen cracking can appear hours or days after welding. In rotating equipment the finding is often a fatigue crack that started at a keyway, a fillet or a threaded section, and in heat-treated parts it can be quench or grinding cracks. Machining marks, scratches and sharp geometry changes can mimic cracks, so indications are cleaned and re-examined before they are recorded.

When an indication is confirmed, the report says where it is and how long it is. Depth has to be established another way, either by controlled grinding followed by re-examination or by ultrasonic measurement, and the owner's engineer decides whether the part is repaired or retired.

Scope, sampling and follow-up

A magnetic particle quote should say how many welds or parts are covered and what happens if a crack turns up. Fabrication codes often specify a percentage of welds for examination. In-service programs prioritize high-stress welds, past repairs and equipment with a history of cracking. If an indication is found in a sampled weld, the usual practice is to examine more welds of the same type, and agreeing that rule in advance keeps a Greenville job moving instead of stopping to renegotiate scope.

Repair work has a built-in sequence: examine, grind out the crack, examine again to prove it is gone, weld, then examine the finished repair. Each stage is documented separately, because a clean result after grinding is evidence that the repair started from sound metal.

Who performs the work

MT is carried out by technicians qualified by Atlantis under its written practice, which is built on ASNT SNT-TC-1A. A Level II technician sets up the equipment, performs the examination and interprets what is found. An ASNT NDT Level III approves the written procedure and reviews each report. The procedure names the code, the magnetizing method, the particle type and the lighting, so the Greenville examination follows what the specification says. For help with your own procedures, the written practice development page describes the service.

What the MT report contains

Surface preparation for magnetic particle work

Most failed magnetic particle examinations fail at the surface. Weld spatter, slag, heavy mill scale and thick paint all keep particles from settling where a crack leaks flux, and sharp weld ripples can trap powder and look like indications. Before the examination, the area is wire brushed or ground flush, oil and grease are cleaned off, and thick coatings are stripped in a band that extends past the weld on both sides. Contrast paint is added thinly when visible particles will be used on dark steel. The few minutes spent on preparation at each location decide whether a finding is real, so owners should budget access and labor for it when scheduling the job.

Planning a magnetic particle job in Greenville

Upstate weather rarely stops MT, but it affects the plan. Summer days can pass 90 degrees Fahrenheit, and hot steel can dry wet particles too quickly or damage contrast paint, so shaded work or early starts help. Winters bring freezing nights and ice storms; cold steel is fine for magnetic particle, but wet suspensions can thicken and the technician's hands need heated gloves. Fluorescent work outdoors needs a tent or dark area, since daylight overwhelms the lamp.

Manufacturing plants have contractor orientation, lock-out and hot-work rules, and crane or press inspection needs the equipment out of production. Atlantis has no office in Greenville, so crews travel to your facility; arrange access and downtime before they mobilize, and confirm whether you need escort, a manlift or scaffolding for overhead structures. Plants running multiple shifts can often give a window on a weekend or between product runs, and examining a crane while it is locked out is far safer than working around it.

MT, PT or UT for your Greenville job

MT is the first choice for surface cracks in carbon and low-alloy steel. If the part is stainless steel, aluminum or another non-magnetic metal, use dye penetrant inspection in Greenville. If you need to know how deep a crack goes or whether the inside of a weld is sound, use ultrasonic inspection in Greenville. The overview of magnetic particle testing services, the complete MT guide and the Article 7 requirements explain the method and the code side in more detail.

Training your own magnetic particle technicians

Greenville plants that inspect their own fabrications or maintain their own cranes often qualify in-house technicians. The MT Level 1 and MT Level 2 courses cover the theory and the practical skills, and the NDT practice tests help trainees prepare. The Greenville NDT training page explains local delivery, and practical qualification is completed at your facility under your written practice.

Frequently asked questions

Which Greenville parts suit magnetic particle inspection?

Carbon and low-alloy steel parts that see stress or have been welded: fabricated frames, crane hooks and girders, press components, shafts, gears and forgings. Stainless steel and aluminum cannot be magnetized and need penetrant testing.

Can MPI be done on painted steel?

A thin, tightly bonded coating may be acceptable if the procedure allows it, but thick, flaking or conductive coatings hide cracks. Most specifications call for bare metal or a controlled thin coating at the examination areas.

When should we use fluorescent instead of visible particles?

Choose fluorescent when the specification requires it, when cracks are fine or tight, or when parts are machined. They need UV-A light and a dark area, while visible particles on contrast paint work in normal light.

Why is each area examined twice?

A crack only produces a strong indication when it crosses the magnetic field. By repeating the examination with the field turned roughly ninety degrees, cracks running in any direction are covered by at least one pass.

Do examined parts need demagnetizing?

If a residual field could affect welding, machining, instruments or later service, the part is demagnetized and the remaining field is measured. The procedure states the requirement and the acceptable residual level.

Does Atlantis have an office in Greenville?

No. Atlantis has no office in Greenville. Technicians are mobilized to your plant for the agreed scope, and an ASNT NDT Level III reviews the report before it is issued.

What do you need from us before the visit?

A list of parts or welds with drawings, material types, the code or customer specification, access arrangements, safety and orientation requirements, and any temperature limits that apply to the surfaces.

How should surfaces be prepared for MPI?

Remove weld spatter, slag, loose scale and thick paint, clean off oil and grease, and grind rough weld ripples where the specification requires. A clean, dry surface lets the particles move freely and gather only at real discontinuities.

Can MT be used on hot parts?

Only within the temperature range the procedure is qualified for. Wet particles and contrast paints have limits, so hot parts must cool or the procedure must be qualified for the higher temperature.

How do Greenville companies train their own MT technicians?

Enroll staff in MT Level 1 and Level 2 training, then complete practical examination on site under your written practice. The employer certifies under SNT-TC-1A, and your Level III approves the practical.

Inspection and training around Greenville

MT by industry for Greenville: Automotive Manufacturing.

MT by job: Magnetic particle weld inspection · Magnetic particle inspection of lifting equipment · Magnetic particle inspection of castings and forgings · Magnetic particle inspection of structural steel and bridges.

Training your own technicians: MT Level 1 training · MT Level 2 training · NDT training for Greenville technicians.

Request an MT inspection quote for Greenville

Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for magnetic particle inspection in Greenville.

Need magnetic particle testing (MT) done, or learned?

Atlantis provides magnetic particle testing (MT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.