Time-of-Flight Diffraction (TOFD) Level II Practice Questions

30 original questions in 6 topics, each with the correct answer, an explanation and its basis. Last reviewed October 16, 2026.

About this TOFD Level II practice test

These 30 multiple-choice questions are original study questions written by Atlantis NDT for ultrasonic technicians working toward Level II in time-of-flight diffraction. They are not ASNT exam questions. They follow the Level II job: choose probes and set the probe center separation, calibrate on the lateral wave and back wall, acquire encoded data, interpret the B-scan, size flaws from arrival times and report against a procedure.

Under ASNT SNT-TC-1A (2024 edition), the employer certifies Level II technicians after general, specific and practical examinations defined in its written practice, which sets the TOFD training and experience it requires. ASNT's central ASNT NDT Level II examinations include UT but do not list TOFD as a separate technique, so the TOFD examinations come from the employer's written practice. A good grounding in conventional UT is assumed.

Atlantis NDT runs NDT training year-round, with theory online and hands-on practice on its Practical NDT simulator or in person at the client's own facility. Simulator practice supports training; it does not replace the practical examination or the experience hours the employer's written practice requires.

How to use this practice test

  • Answer each question before opening the explanation.
  • For the sizing questions, draw the two probes, the tip and the two half-paths; the depth falls out of a right-angled triangle.
  • Keep units consistent: velocity in mm/µs (5.9 for steel longitudinal) makes the arithmetic quick.
  • Note the topics where you miss questions, study them against your employer's TOFD procedure, then re-test.

Topics in this set:

Practice questions, not exam questions

Atlantis NDT wrote these questions as original study material. They are not taken from ASNT or from any employer's examination, and real examinations differ in wording, emphasis and format.

Certification is a separate step: under ASNT SNT-TC-1A the employer certifies its technicians after the examinations its written practice sets, and ASNT runs central Level II examinations for several methods. A good score here is a study signal, not a qualification.

Principles of diffraction

Question 1. Which signal from a flaw does TOFD mainly rely on for detection and sizing?

  1. A. Specular reflection from the flaw face
  2. B. Diffracted signals from the flaw tips
  3. C. Loss of through-transmitted amplitude only
  4. D. Surface waves generated at the flaw
Show answer

Correct answer: B. Diffracted signals from the flaw tips

When sound strikes the tip of a crack-like flaw, diffracted energy spreads over a wide range of angles. TOFD records these weak tip signals and uses their arrival times, rather than echo amplitude, to locate and size the flaw.

Basis: General TOFD principle; ASTM E2373

Question 2. Why is TOFD height sizing less dependent on flaw orientation than amplitude-based sizing?

  1. A. Because TOFD uses shear waves, which are not affected by orientation
  2. B. Because the instrument automatically corrects amplitude for orientation
  3. C. Because diffraction is weakly directional and sizing uses arrival times
  4. D. Because TOFD can only detect flaws perpendicular to the surface
Show answer

Correct answer: C. Because diffraction is weakly directional and sizing uses arrival times

Diffraction from a tip is weak but not strongly directional, and the depth of each tip is calculated from its arrival time. The echo amplitude, which depends heavily on orientation, is not used for sizing.

Basis: General TOFD principle

Question 3. In a TOFD A-scan with longitudinal-wave probes, which signal normally arrives first?

  1. A. The lateral wave, just below the surface between the probes
  2. B. The back-wall echo, reflected from the far surface of the plate
  3. C. The upper-tip signal from a flaw at mid-wall, if one is present
  4. D. The mode-converted shear back-wall signal
Show answer

Correct answer: A. The lateral wave, just below the surface between the probes

The lateral wave takes the shortest path, directly between the probes just beneath the surface, so it arrives first. Tip signals from flaws follow, then the back-wall echo, then the slower mode-converted signals.

Basis: General TOFD principle

Question 4. How do the diffracted signals from the upper and lower tips of an embedded crack normally compare in phase?

  1. A. In phase with each other, since both come from the same flaw
  2. B. Opposite in phase, the upper tip matching the back wall
  3. C. Only the upper tip gives a signal; the lower tip is shadowed
  4. D. Their phase depends only on the probe frequency and the PCS
Show answer

Correct answer: B. Opposite in phase, the upper tip matching the back wall

The upper and lower tip signals are 180° apart in phase. The lateral wave and back-wall echo are also opposite in phase, and the upper tip normally matches the back wall while the lower tip matches the lateral wave, which helps identify each tip.

Basis: General TOFD principle; ISO 10863

Question 5. Which signals in a TOFD A-scan arrive after the longitudinal back-wall echo?

  1. A. The lateral wave, which travels the longest path
  2. B. Upper-tip signals from flaws lying just below the scanning surface
  3. C. The initial transmitter pulse, delayed by the wedges
  4. D. Mode-converted shear-wave signals, such as the shear back wall
Show answer

Correct answer: D. Mode-converted shear-wave signals, such as the shear back wall

Mode conversion at flaws and at the back wall produces shear-wave components that travel more slowly than longitudinal waves, so they arrive after the longitudinal back wall. The region of interest therefore arrives before the mode-converted signals.

Basis: General TOFD principle

Probes and PCS set-up

Question 6. What probe arrangement is normally used for TOFD weld examination?

  1. A. A single shear-wave probe in pulse-echo mode, scanned from both sides of the weld
  2. B. A 0° dual-element probe scanned along the weld cap
  3. C. A longitudinal-wave transmitter and receiver facing each other across the weld
  4. D. Two surface-wave probes placed side by side on one side of the weld
Show answer

Correct answer: C. A longitudinal-wave transmitter and receiver facing each other across the weld

TOFD is a pitch-catch technique: one probe transmits, the other receives the lateral wave, tip diffractions and back wall. The pair straddles the weld so the beams cover the weld volume.

Basis: General TOFD practice; ASTM E2373

Question 7. Why are longitudinal waves used rather than shear waves for TOFD?

  1. A. They arrive first, ahead of all slower mode-converted signals
  2. B. Shear waves cannot be diffracted by the tip of a crack
  3. C. Longitudinal waves do not spread, so the beam stays narrow
  4. D. Shear waves are absorbed completely in carbon steel welds
Show answer

Correct answer: A. They arrive first, ahead of all slower mode-converted signals

Longitudinal waves are the fastest mode, so the lateral wave, tip signals and back wall all arrive before any mode-converted signals and the time window is simple to interpret. Shear waves do diffract at crack tips and do travel through carbon steel welds, and longitudinal beams spread like any other; shear waves are simply slower.

Basis: General TOFD principle

Question 8. Why are highly damped, broadband probes used for TOFD?

  1. A. To increase the refracted angle of the beam in the part
  2. B. To give short pulses for good depth resolution and smaller dead zones
  3. C. To make the lateral wave disappear from the display
  4. D. To allow the probes to work without couplant on smooth, clean plate
Show answer

Correct answer: B. To give short pulses for good depth resolution and smaller dead zones

Short pulses allow closely spaced signals, such as two tips of a small flaw or a tip just below the lateral wave, to be separated in time. Long ringing pulses enlarge the dead zones and blur the tip signals.

Basis: General TOFD principle

Question 9. For a 30 mm thick plate with 60° probes, what probe center separation (PCS) places the beam intersection at two-thirds of the thickness?

  1. A. 34.6 mm
  2. B. 52.0 mm
  3. C. 103.9 mm
  4. D. 69.3 mm
Show answer

Correct answer: D. 69.3 mm

PCS = 2 × (2/3 × T) × tan θ = 2 × 20 × tan 60° = 40 × 1.732 ≈ 69.3 mm. Setting the intersection at the full thickness would give 103.9 mm, and 34.6 mm is only half the required separation.

Basis: TOFD set-up geometry (common practice: intersection at about 2/3 T)

Question 10. Why are thick welds often examined with more than one TOFD probe pair or scan, each set up for a different depth zone?

  1. A. Because one pair cannot cover the whole thickness with enough resolution
  2. B. Because TOFD can only detect flaws exactly at the beam intersection point
  3. C. Because the encoder can only record a limited depth range
  4. D. Because the back-wall echo must be excluded from every scan
Show answer

Correct answer: A. Because one pair cannot cover the whole thickness with enough resolution

Beam spread, attenuation and resolution all vary with depth, so thick sections are divided into zones, each with its own probe angle, frequency and PCS. A single pair still covers more than just the intersection point, but not the full thickness well.

Basis: General TOFD practice; ISO 10863

Calibration and data acquisition

Question 11. Why is TOFD gain commonly set so that low-level grain noise is just visible across the display?

  1. A. To make the back-wall echo saturate so it is easy to see
  2. B. Because diffracted tip signals are weak and need high sensitivity
  3. C. To remove the lateral wave from the top of the display
  4. D. Because the grain noise is needed to calibrate the encoder distance
Show answer

Correct answer: B. Because diffracted tip signals are weak and need high sensitivity

Tip diffractions are much weaker than reflections from flaw faces. Setting gain so that material noise is just visible shows the system is sensitive enough to record weak tip signals; the procedure defines the exact sensitivity setting.

Basis: General TOFD practice

Question 12. Where should the TOFD acquisition time window normally start and end?

  1. A. Start at the back-wall echo and end at the shear back wall
  2. B. Start just after the lateral wave and end just before the back-wall echo
  3. C. Start before the lateral wave and end after the back-wall echo
  4. D. Start at the initial pulse and end at the lateral wave
Show answer

Correct answer: C. Start before the lateral wave and end after the back-wall echo

The window must contain every signal that can come from the examined volume, from the lateral wave (scanning surface) to the back wall. Including the mode-converted region helps confirm indications near the back wall. The procedure or standard sets the exact margins.

Basis: ASTM E2373; ISO 10863

Question 13. Why must the digitization (sampling) rate be several times higher than the probe's nominal frequency?

  1. A. To increase the penetration of the probe into the weld
  2. B. To reduce the size of each data file
  3. C. To capture the waveform shape and phase faithfully for sizing
  4. D. Because the encoder needs a high sampling rate to count distance
Show answer

Correct answer: C. To capture the waveform shape and phase faithfully for sizing

TOFD relies on accurate arrival times and on phase to identify tips. Under-sampling distorts the waveform and introduces timing errors. Higher sampling increases file size rather than reducing it.

Basis: General TOFD practice; ASTM E2373

Question 14. Why is the TOFD set-up checked on a reference block containing reflectors such as notches or side-drilled holes at known depths before scanning?

  1. A. To confirm coverage, sensitivity and depth calibration
  2. B. To measure the hardness of the weld and heat-affected zone
  3. C. To determine the client's acceptance criteria for the weld
  4. D. To set the scanner speed only
Show answer

Correct answer: A. To confirm coverage, sensitivity and depth calibration

Known reflectors at the top, middle and bottom of the zone show that the beams reach them, that their signals are visible at the chosen gain and that the calculated depths are right. Acceptance criteria come from the code or specification.

Basis: ASTM E2373; ISO 10863

Question 15. On the component, the lateral wave and back-wall arrival times are measured with a known plate thickness and PCS. What can these two signals be used to calibrate?

  1. A. The probe frequency and the pulse bandwidth
  2. B. The weld acceptance level for the scan
  3. C. The encoder resolution and scan increment
  4. D. The probe delay and the depth scale
Show answer

Correct answer: D. The probe delay and the depth scale

The lateral wave corresponds to zero depth and the back wall to the known thickness. With the PCS known, these two references fix the time zero (probe delay) and the velocity used to convert arrival times into depths.

Basis: General TOFD practice

Interpretation of TOFD images

Question 16. How does an embedded planar flaw typically appear in a TOFD B-scan (D-scan) image?

  1. A. As a break in the lateral wave, with no signal between it and the back wall
  2. B. As a break in the back-wall echo, with no signal between it and the lateral wave
  3. C. As a single short hyperbolic arc with no measurable depth extent
  4. D. As two opposite-phase tip signals, with the lateral wave and back wall undisturbed
Show answer

Correct answer: D. As two opposite-phase tip signals, with the lateral wave and back wall undisturbed

An embedded flaw with measurable height has two tips, each producing its own diffraction signal, and it does not interrupt the lateral wave or the back wall. A single short arc is typical of a point reflector.

Basis: General TOFD interpretation; ISO 10863

Question 17. How does a flaw breaking the scanning surface typically appear in TOFD?

  1. A. As a break in the lateral wave plus a lower-tip signal
  2. B. As two separate tip signals below an undisturbed lateral wave
  3. C. As a break in the back-wall echo, with the lateral wave intact
  4. D. As a signal arriving after the mode-converted shear back wall
Show answer

Correct answer: A. As a break in the lateral wave plus a lower-tip signal

A flaw open to the scanning surface interrupts the lateral wave path; its only separate tip is the lower one. Its upper end is at the surface, inside the lateral wave.

Basis: General TOFD interpretation

Question 18. How does a crack open to the back wall (inside surface) typically appear in TOFD?

  1. A. As a lower-tip signal only, with an undisturbed back wall
  2. B. As an upper-tip signal plus a break in the back-wall echo
  3. C. As an interruption of the lateral wave only
  4. D. No signal appears, since TOFD cannot detect such flaws
Show answer

Correct answer: B. As an upper-tip signal plus a break in the back-wall echo

The crack's lower end is at the back wall, so instead of a lower-tip signal the back-wall echo is disturbed or shadowed beneath the flaw. The upper tip gives a diffraction signal above it.

Basis: General TOFD interpretation

Question 19. How does a point reflector, such as an isolated pore, typically appear in a non-parallel TOFD scan?

  1. A. As a long flat line parallel to the lateral wave
  2. B. As a break in the back-wall echo
  3. C. As a short hyperbolic arc with little depth extent
  4. D. As a disturbance of the lateral wave
Show answer

Correct answer: C. As a short hyperbolic arc with little depth extent

As the probes approach and pass a point reflector, the arrival time first decreases and then increases, producing a characteristic hyperbolic arc. It has no measurable height, unlike a planar flaw with separate upper and lower tips.

Basis: General TOFD interpretation

Question 20. Why is the phase of TOFD signals useful during interpretation?

  1. A. It shows the probe frequency actually achieved
  2. B. It indicates the flaw's chemical composition, such as slag or oxide
  3. C. It replaces the need for an encoder on short scans
  4. D. It shows whether a signal is an upper or a lower tip
Show answer

Correct answer: D. It shows whether a signal is an upper or a lower tip

Because upper and lower tips give opposite phases, the analyst can tell whether a single signal is an upper tip (suggesting a back-wall-breaking flaw) or a lower tip (suggesting a scanning-surface-breaking flaw), and can pair the tips of an embedded flaw.

Basis: General TOFD interpretation

Question 21. Over a short section of the scan, the lateral wave and the back-wall echo both disappear. What is the most likely cause?

  1. A. A large embedded crack between the two probes
  2. B. Loss of coupling, so that section must be rescanned
  3. C. A lamination at mid-thickness under both probes
  4. D. Normal behavior; these signals often fade on thick plate
Show answer

Correct answer: B. Loss of coupling, so that section must be rescanned

An embedded flaw does not remove the lateral wave, and a mid-wall lamination would block the back wall but not the lateral wave. Losing both together points to coupling, and the data in that section cannot be evaluated.

Basis: General TOFD practice (data quality)

Sizing and calculations

Question 22. A TOFD set-up uses a PCS of 80 mm on steel (longitudinal velocity 5,900 m/s). After removing the probe delay, a tip signal arrives at 16.95 µs. What is the depth of the tip, assuming it lies midway between the probes?

  1. A. 25.0 mm
  2. B. 30.0 mm
  3. C. 40.0 mm
  4. D. 50.0 mm
Show answer

Correct answer: B. 30.0 mm

Total path = 5.9 mm/µs × 16.95 µs ≈ 100 mm, so each half-path is 50 mm. With half the PCS S = 40 mm, depth d = √(50² − 40²) = √900 = 30.0 mm. 50 mm is the half-path, not the depth.

Basis: TOFD depth equation, d = √((ct/2)² − S²)

Question 23. In the same set-up (PCS 80 mm, 5,900 m/s), the upper tip of a flaw is at 30.0 mm depth and the lower-tip signal arrives at 19.66 µs. What is the flaw height?

  1. A. 2.7 mm
  2. B. 8.0 mm
  3. C. 16.0 mm
  4. D. 12.0 mm
Show answer

Correct answer: D. 12.0 mm

Total path = 5.9 × 19.66 ≈ 116 mm, half-path 58 mm. Lower-tip depth = √(58² − 40²) = √1,764 = 42.0 mm. Height = 42.0 − 30.0 = 12.0 mm. Height is a difference in depth, not the difference in path or time.

Basis: TOFD depth equation, d = √((ct/2)² − S²)

Question 24. How is flaw length normally measured in a non-parallel TOFD scan?

  1. A. From the time difference between the upper and lower tip signals
  2. B. From the peak amplitude of the A-scan at the flaw center
  3. C. From the duration of the lateral wave signal in the A-scan
  4. D. Along the scan axis, with hyperbolic cursors fitted to the ends
Show answer

Correct answer: D. Along the scan axis, with hyperbolic cursors fitted to the ends

Length lies along the encoded scan axis. Because beam spread makes the ends trail off as arcs, hyperbolic cursors are fitted to the ends rather than reading where the signal visibly fades. The tip time difference gives height, not length.

Basis: General TOFD sizing practice; ISO 10863

Question 25. In a non-parallel TOFD scan, the depth calculation assumes the flaw lies midway between the probes. What is the effect if the flaw is actually off-center?

  1. A. The depth is overestimated, because an off-center tip has a longer path
  2. B. There is no effect, because TOFD depth is independent of lateral position
  3. C. The flaw cannot be detected at all by the receiver
  4. D. The calculated height doubles but depth is unchanged
Show answer

Correct answer: A. The depth is overestimated, because an off-center tip has a longer path

For a given depth, the sound path is shortest at the midpoint between the probes. An off-center tip has a longer path, so the midpoint assumption gives a depth greater than the true depth. A parallel scan or offset scans can be used to locate the flaw laterally.

Basis: TOFD geometry (lateral position uncertainty)

Limitations, codes and documentation

Question 26. Why are flaws very close to the scanning surface difficult to detect and size with TOFD?

  1. A. Their signals arrive after the back wall and are outside the window
  2. B. Diffraction does not occur at tips close to the surface
  3. C. Their tip signals arrive within the lateral wave and are masked
  4. D. The encoder cannot record positions for near-surface signals
Show answer

Correct answer: C. Their tip signals arrive within the lateral wave and are masked

The lateral wave has a finite duration, and signals from tips just below the surface arrive within it. Higher frequency, shorter pulses or a smaller PCS shrink this dead zone, and supplementary techniques such as pulse-echo UT or PAUT are commonly used to cover it.

Basis: General TOFD principle (dead zones)

Question 27. What limits TOFD detection of small flaws very close to the back wall?

  1. A. Their tip signals are masked by the back-wall echo
  2. B. The lateral wave interferes with them
  3. C. Mode-converted signals arrive before them and hide them
  4. D. Longitudinal waves cannot reach the back wall of thick plate
Show answer

Correct answer: A. Their tip signals are masked by the back-wall echo

A tip signal that arrives within the duration of the back-wall echo cannot be separated from it, which creates a back-wall dead zone. The mode-converted signals arrive after, not before, the longitudinal back wall.

Basis: General TOFD principle (dead zones)

Question 28. Which pair of standards specifically addresses TOFD examination of welds?

  1. A. ASTM E2700 and ISO 13588
  2. B. ASTM E2373 and ISO 10863
  3. C. ASTM E309 and ASTM E426
  4. D. ASTM E1444 and ISO 9934
Show answer

Correct answer: B. ASTM E2373 and ISO 10863

ASTM E2373 and ISO 10863 cover TOFD. ASTM E2700 and ISO 13588 cover phased array UT of welds, ASTM E309 and E426 cover eddy current examination of tubular products, and ASTM E1444 and the ISO 9934 series cover magnetic particle testing.

Basis: ASTM E2373; ISO 10863

Question 29. Which joint condition makes a standard TOFD scan difficult or impossible?

  1. A. A flat butt weld with clear access on both sides on the same surface
  2. B. A weld with the cap ground flush to the plate surface
  3. C. A nozzle or tee joint without access to both sides on one surface
  4. D. A plate thicker than the probe's near-field length
Show answer

Correct answer: C. A nozzle or tee joint without access to both sides on one surface

Standard TOFD needs the transmitter and receiver on opposite sides of the weld on the same surface. Where geometry prevents that, other techniques or special configurations are needed. A flush cap actually helps scanning.

Basis: General TOFD practice (limitations)

Question 30. Which information should a TOFD report contain so the examination can be reproduced?

  1. A. The list of rejected indications with their positions
  2. B. The operator's name, the date and the client's order number
  3. C. Probes, PCS, time window, sensitivity, reference block, scan plan and data file
  4. D. The color palette and print settings used for the images
Show answer

Correct answer: C. Probes, PCS, time window, sensitivity, reference block, scan plan and data file

Another qualified technician must be able to rebuild the set-up and coverage from the report, and the data file must be traceable to it. Indications, the operator and the date are recorded too, but alone they do not allow the examination to be repeated.

Basis: General NDT reporting practice; ASTM E2373

Next step: TOFD training course

Practice questions check recall. Structured training adds the classroom and hands-on hours your certification route requires. The TOFD training course covers probe-pair configuration and probe centre spacing, lateral-wave and back-wall identification, and D-scan depth sizing. Completing a course is not certification: under an employer-based scheme such as SNT-TC-1A, your employer certifies you after its own examinations.

For employers: ASNT Level III consulting covers procedures, the written practice, qualification examinations and audit support for your technicians.

Where to go next

Atlantis NDT courses run year-round, with theory online and hands-on practice on the Practical NDT simulator or in person at the client's own facility. From here:

Enquire about TOFD Level II training for yourself or for a team. Tell us the method, the level and where the trainees are based.

Practise before the exam

Written papers test what you know; employers and practical examinations test what you can do with a probe in your hand. Use the free practice tests to find your gaps, then practise the technique.

Free downloads

Download these directly: no form and no email address needed.

  • ExcelTOFD reportExcel workbook, written as Atlantis Engineering Consultants with no logo, so you can add your own.Download .xlsxAbout this template
  • ExcelPhased array (PAUT) reportExcel workbook, written as Atlantis Engineering Consultants with no logo, so you can add your own.Download .xlsxAbout this template
  • PDFUT Level II General practice questions40 questions. PDF with an answer key and explanations.Download PDF

Need more templates, or templates made for your work?

These downloads are a free starter set. Atlantis NDT also prepares report templates, practice and qualification exams, and document packs matched to your industry, method, code and client format: PAUT and TOFD data sheets, IRIS and eddy-current tube reports, MFL tank-floor reports, hardness, PMI and holiday-test records, calibration and equipment logs, and complete report packs aligned with your written practice. Tell us what you need and we will reply with a quotation.

Request custom templatesAll free report templates · All practice tests