Ultrasonic Testing (UT) Inspection in Wichita, Kansas

Atlantis NDT mobilizes Level II technicians to Wichita, Kansas for ultrasonic thickness testing and ultrasonic weld inspection on storage tanks, process and utility piping, pressure vessels, structural steel and plant equipment. We have no office in the city, so the crew travels to your site, works to your procedure or ours, and sends a report your inspector can act on. To scope a job, request a UT quote for Wichita and tell us the asset, the wall thickness and the code.

Where ultrasonic testing is used in Wichita

Wichita is an aircraft-manufacturing city first. Textron Aviation, Spirit AeroSystems, Learjet and Airbus all have operations here, and the Greater Wichita Partnership counts more than 450 suppliers working around them. What that means for ultrasonic work is less obvious than the airframes themselves. Behind every production floor sits a utility plant: compressed-air receivers, steam and hot-water systems, chilled-water loops, fuel storage and the large pressure vessels used to cure composite parts. Those assets lose wall to corrosion like any other steel, and an ultrasonic thickness survey is how an owner learns how much is left.

The same survey logic applies to the older industrial stock that grew up with Wichita's oil history. Oil discoveries in nearby Butler County in the 1910s pulled refining and energy offices into the city, and the region still carries tank farms, gathering and transmission piping, and rail-served terminals. Add grain handling, food processing, hangar and plant structural steel, and the steel in the flood-control and river crossings that Wichita depends on, and the list of ultrasonic candidates is long and varied.

What ultrasonic testing finds and what it misses

Two jobs dominate. The first is thickness measurement: a transducer sends a sound pulse into the steel, the instrument times the echo from the back wall, and the reading tells you remaining wall at that point. The second is weld examination with an angle beam, which sends shear waves into the weld and heat-affected zone to look for lack of fusion, cracks, slag and incomplete penetration that a surface method cannot see.

Ultrasound does not see everything. Thickness readings describe the spot under the probe, so a pitted floor or a patch of under-deposit corrosion can hide between grid points. Rough scale, thick coatings, curved small-diameter pipe and coarse-grained cast or heavily worked material all weaken the signal. Laminations can send a straight beam to the wrong depth. A Level II technician plans around these limits and tells you where the data is thin; the report is only as honest as its stated coverage.

Codes and acceptance criteria that apply in Wichita

The method follows the code that governs the asset. For ultrasonic examination of welds, ASME Section V Article 4 sets the examination method, while the construction code supplies the acceptance limits: ASME Section VIII Division 1 Appendix 12, ASME B31.3 Table 341.3.2 for process piping, ASME B31.1 for power piping, AWS D1.1 for structural steel groove welds, and API 1104 where pipeline welds are involved. Contact thickness gauging is covered by ASTM E797 and the thickness provisions of Article 23 in Section V. Our guide to ultrasonic thickness requirements explains the calibration and documentation points in plain terms.

Kansas has its own boiler safety act in Chapter 44, Article 9 of the Kansas statutes, and that act lists exemptions, among them certain refinery equipment inspected in-plant and pressure vessels built before 1999. Whether a given vessel falls under the act is a question for the owner and the jurisdiction. Under API 510, 570 and 653 the owner's authorized inspector remains the inspector of record. Atlantis performs the ultrasonic work and reports the data, such as thickness at condition monitoring locations, for that inspector to evaluate.

How the work is done

For thickness surveys, the technician calibrates on a step block made of the same material, using a dual-element probe where the outside surface is corroded and a single-element probe on clean, smooth wall. The A-scan display stays on screen so the technician can reject doubled echoes and see when a reading is really a lamination. On hot lines, a high-temperature probe and couplant are used and the readings are corrected for temperature. Readings are taken at marked condition monitoring locations so the next survey can repeat them exactly.

Weld work starts with a procedure written to the code, a calibration block, and a reference level built from side-drilled holes. The technician scans from both sides where access allows with 45, 60 or 70 degree angle beams, marks every reflector that crosses the reporting threshold, then characterizes length and position before comparing to the acceptance table. Surface preparation, grinding of weld crowns and clean scanning lanes decide whether that scan can be trusted.

Thickness surveys in practice: grids, corrosion rates and remaining life

A one-time reading tells you where the wall is today. A repeated reading at the same marked spots tells you how fast it is going, and that rate is what turns a number into a decision. On a storage tank, utility vessel or piping circuit, the usual plan is a grid on the shell or floor course, readings at every condition monitoring location on a line, and extra points around nozzles, elbows, tees and low points where water and deposits collect. Corrosion rate is the change in thickness divided by the time between readings, and remaining life is the margin above minimum required thickness divided by that rate. The calculation belongs to the owner's engineer or authorized inspector; our job is to deliver readings that are repeatable enough to support it.

Repeatability depends on discipline. We mark each location with paint or a stamped tag, record the probe and couplant, and note whether the reading was taken through paint or on bare metal, because a coating can add apparent thickness if the instrument is not set up for it. When a reading looks low or erratic, the technician scans around the point to separate a true pit from a lamination or a poor couplant film, then records the minimum found in the area rather than only the single nominal location.

Weld examination: what the angle beam is really doing

Shear-wave examination is a matter of geometry. The probe wedge refracts the beam into the steel at a fixed angle, and the technician moves the probe in a controlled raster pattern while watching the display for echoes that line up with the weld. A reflector from lack of fusion at the bevel face shows differently from slag in the root or a crack at the toe, and an experienced Level II uses the beam path, the probe position and the echo shape together to decide what the signal really is. Geometry reflectors such as root reinforcement and weld crown can look like flaws, so the technician plots the signal position against a sketch of the joint before calling anything an indication.

Sensitivity is set from a reference reflector in a calibration block of the same material and thickness range. Scanning gain is then raised above reference to find small signals, and every indication above the reporting level is evaluated by amplitude and length. On heavier sections, more than one beam angle and scanning from both sides improve the chance of catching a flaw that is oriented unfavorably for one direction. Where the weld cap is left unground or the heat-affected zone is not accessible, the report states the loss of coverage.

Typical Wichita assets and the question each one raises

Who does the work

Our technicians are qualified under the company's written practice, which follows ASNT SNT-TC-1A. A Level II performs the setup, calibration, examination and interpretation, and an ASNT Level III approves the procedures and reviews the reports before they leave. Report review sits with our founder, Anoop Rayavarapu, ASNT NDT Level III in UT, RT, MT, PT and VT. Atlantis is certified to ISO 9001 and ISO 14001, which covers how we control documents and records, not the examination itself. If your site requires a customer-specific aerospace procedure, send it with the request and we will read it against our written practice before agreeing scope.

What the UT report contains

Every report identifies the component, the line or tag number, the procedure and revision, the instrument, probe and calibration block, and the technician and level. For thickness work you get a grid or table of readings by location, nominal thickness, previous readings where they exist, and the minimum found. For weld work you get indication locations on a sketch, length, amplitude against the reference level, and an accept or reject call against the named criterion. Limitations such as inaccessible areas or a poor surface are written down rather than left for the reader to guess.

Planning a UT job in Wichita

Wichita weather shapes the schedule more than people expect. Summer brings days at or above 90 degrees about 65 times a year, with a few at 100, so hot steel and heat-affected technicians matter for exterior tank work. Winter lows are cold enough that couplant thickens and flaw detector screens slow down, and spring thunderstorms with hail and high wind can close a job at short notice. Aerospace plants and food plants add their own access rules: badging, foreign-object control, lockout and permits are normal. We ask for the safety orientation requirements, escort rules and permit process in the first call so crews arrive prepared. Travel is booked around your outage window, and the crew works from your site.

UT versus MT and PT for your Wichita job

Use ultrasound when the question is wall loss or what is inside a weld. Use magnetic particle testing in Wichita when the question is surface cracking on carbon or low-alloy steel, and liquid penetrant testing in Wichita when the material is non-ferrous or stainless and the concern is a surface-breaking flaw. Many inspection plans combine them: UT for the volumetric weld check, then MT or PT on the cap and toe. Our national pages on ultrasonic testing describe the method in general terms.

Training your own UT technicians

Plants with steady thickness work often prefer to qualify their own staff. We offer UT Level 1 training and UT Level 2 training, with a browser ultrasonic testing simulator for practice before hands-on time at your own facility, and a Wichita training page that explains how the delivery works. Under SNT-TC-1A the employer certifies its personnel; we supply the training and the Level III oversight.

Frequently asked questions

Does Atlantis have an office in Wichita?

No. Atlantis has no office in Wichita. Technicians are mobilized to your site for the agreed scope, work under the company's written practice, and report back with a document your own inspector can review and file.

Can you measure wall thickness on tanks and piping in Wichita?

Yes. We run ultrasonic thickness surveys on tanks, piping, vessels and structural steel, calibrated on a matching step block, with readings recorded at marked condition monitoring locations so later surveys can be compared point for point.

Do you perform ultrasonic weld inspection?

Yes. Angle-beam shear wave examination of groove welds is done to a written procedure, with a reference level built from side-drilled holes, and indications are compared with the acceptance table of the governing code before the report is issued.

Which codes do your UT reports follow?

That depends on the asset. Typical references are ASME Section V Articles 4, 5 and 23, ASME Section VIII Division 1, ASME B31.3 and B31.1, AWS D1.1 for structural steel, API 1104 for pipeline welds and ASTM E797 for thickness.

Who is the inspector of record on API 510, 570 or 653 work?

Your authorized inspector. Atlantis does not act as that inspector; we perform the ultrasonic examination, report thickness and indication data, and your inspector evaluates it against the applicable inspection code.

What can stop ultrasonic testing from giving a good result?

Heavy scale, thick coatings, rough weld caps, very small diameters, hot surfaces without suitable couplant and coarse-grained material all degrade the signal. We note these conditions and recommend surface preparation or a different method when they matter.

How do I request a quote for ultrasonic inspection in Wichita?

Use the quote link on this page or the contact form, and send the asset type, material, wall thickness, governing code, access constraints and your outage window. Expect our reply within one business day.

Will you work to our own procedure or customer specification?

Yes, if it fits the examination. Send the procedure or specification early; our Level III reads it against our written practice and tells you whether we can work to it, or what needs to be added, before any technician is mobilized.

Can you train our technicians in ultrasonic testing?

Yes. We provide UT Level 1 and Level 2 training with Level III oversight and a simulator for practice. Qualification and certification stay with your company under its written practice, as SNT-TC-1A requires.

Inspection and training around Wichita

UT by industry for Wichita: Aviation & Aerospace · Wind Energy.

UT by job: Ultrasonic pipe thickness testing · Ultrasonic weld inspection · Ultrasonic boiler tube thickness testing · Ultrasonic testing of castings and forgings.

Training your own technicians: UT Level 1 training · UT Level 2 training · NDT training for Wichita technicians.

Request an UT inspection quote for Wichita

Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for ultrasonic testing in Wichita.

Need ultrasonic testing (UT) done, or learned?

Atlantis provides ultrasonic testing (UT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.