Ultrasonic Testing (UT) Inspection in Tacoma, Washington
Atlantis NDT carries out ultrasonic thickness testing and ultrasonic weld inspection in Tacoma, Washington, for waterfront cranes, process piping and tanks on the tideflats, vessels, bridge steel and heavy fabrications around Commencement Bay. Technicians are mobilized to your terminal, plant or yard with calibrated instruments and a written procedure, and readings are reported against the code or specification you name. To start a scope, use the Tacoma UT inspection quote request; we reply within one business day.
Where ultrasonic testing is needed in Tacoma
Tacoma is a working harbor. The port is a naturally deepwater harbor on Commencement Bay in south Puget Sound, with container terminals operated through the Northwest Seaport Alliance and roughly 2,500 acres of port-owned land hosting a mix of maritime and industrial tenants. Ship-to-shore container cranes, rail-mounted gantries and heavy-lift equipment are all welded steel structures that live in salt air and see cyclic loading every working day. Their boom girders, backreach frames, legs and sill beams are classic places for ultrasonic weld examination and for thickness checks on corroded members. Along the waterways behind the terminals, the tideflats hold fuel and chemical storage, a pulp and paperboard industry, metals processing and an LNG facility, each with tanks, vessels and process piping whose walls thin with time.
Away from the water, Tacoma's history in smelting and shipbuilding left a base of fabricators and repair yards, and the Tacoma Narrows crossings and other steel bridges of the Puget Sound region keep state transportation crews busy. Pipe racks, pressure vessels at pulp and paper operations, and water and wastewater plants complete the picture. For almost all of it, the wall thickness of a pipe or vessel is a number that someone needs, and ultrasonic testing provides it without taking the system apart.
What ultrasonic testing can and cannot tell you
An ultrasonic instrument sends a short sound pulse through a probe into the steel and measures the time taken for the echo to return. On a plain plate that time gives thickness; on a weld, the pattern of echoes from within the metal marks the location and approximate size of a flaw. The strength of UT is that it looks through the metal, so it can find internal corrosion on a pipe wall and planar defects deep in a weld that no surface method would see. Its weaknesses are practical. The surface must be clean and smooth enough for the probe to couple, and thick marine paint, scale or barnacle residue gets in the way. Wet, corroded and pitted surfaces scatter sound. Austenitic and cast welds with coarse grains blur the signal. And UT gives information at the points scanned, so the survey plan has to put the readings where the damage is likely to be.
Thickness surveys on piping, tanks and cranes
Thickness work follows the contact pulse-echo method in ASTM E797 and ASME Section V Article 5, with SE-797 in Article 23. Corroded surfaces call for dual-element probes, which keep transmitter and receiver apart and cope better with rough metal. The instrument is calibrated on a step block made from material of matching sound velocity, and the technician checks the A-scan trace to be sure the echo is the true back wall and not a lamination or a doubled signal on a thin point. Salt air accelerates external corrosion at the base of columns, at bolted connections and under insulation, so the survey grid is usually denser in splash and drip zones.
For pressure piping and vessels, readings are taken at condition monitoring locations marked on the inspection drawings, commonly in grids on elbows, tees, dead legs and nozzle necks. Where the owner is working under API 570, API 510 or API 653, the authorized inspector is responsible for remaining-life and interval decisions; Atlantis supplies the thickness data and a report suited to that inspector's records. Storage tank work follows the same pattern, with shell course readings taken on a vertical and circumferential grid.
Shear-wave weld inspection
For welds, the technician uses angle-beam probes, normally 45, 60 or 70 degrees, which send shear waves through the weld and heat-affected zone. A reference level is set from side-drilled holes in a calibration block, the weld is scanned from both sides where the geometry allows, and reflectors above the recording threshold are characterized by position, length and amplitude. Acceptance is taken from the governing code: ASME Section VIII Division 1 Appendix 12, ASME B31.3, AWS D1.1 for groove welds in structural steel, or API 1104 where an owner specifies ultrasonic examination of pipeline girth welds. Bridge steel is examined to AWS D1.5, which Washington's state transportation work follows. Whether ultrasonic examination can replace radiography on a particular job is decided by the owner, the engineer and the inspector before work starts, and the substitution goes into the written procedure.
Washington regulations that matter
Washington's Department of Labor and Industries runs the state boiler and pressure vessel program. Inspectors who work under it hold a commission after passing the National Board examination and a Washington examination, and the state's rules are collected in Chapter 296-104 of the Washington Administrative Code. Tacoma adds a local requirement: the city requires a license for boiler operators, a requirement the state itself does not impose. Repairs and alterations to pressure equipment follow the National Board Inspection Code. Pipelines are regulated under 49 CFR Parts 192 and 195, and plants subject to OSHA process safety management must keep mechanical-integrity records that show inspection and testing in line with recognized and generally accepted good engineering practice. A thickness report is one of the building blocks of those records.
Who does the work and what the report contains
No Atlantis office exists in Tacoma, so technicians travel to your site for the agreed scope. They are qualified by the company under its written practice, based on ASNT SNT-TC-1A, with Level II technicians performing and interpreting the examination and an ASNT Level III approving procedures and reviewing reports. The Level III is the founder, Anoop Rayavarapu, ASNT NDT Level III in UT, RT, MT, PT and VT. Atlantis is certified to ISO 9001 and ISO 14001. Your own program may require to see the written practice and the technician's qualification file; both can accompany the quote.
Each report identifies the component and drawing, the procedure and revision, instrument, probes and calibration block, couplant, surface condition and temperature, technician and level, and date. Thickness results are given in a grid with nominal and minimum required values alongside, and weld results list each indication by location along the weld, depth, length and amplitude with an accept or reject disposition against the named criteria.
Planning a UT job in Tacoma
The Pacific Northwest climate shapes the schedule more than the temperature does. Tacoma is wet for much of the year, and rain on exposed steel is more of a problem than cold; couplant works in the damp but instruments and cables need protecting, and surface moisture can hide corrosion scale. Summers are mild and dry, which is why many survey campaigns on exterior structures are timed for July through September. Waterfront sites require port-issued credentials and safety orientation, and secure terminal areas limit where a crew can park and carry equipment. Crane work is scheduled around vessel calls, because a crane that is working cannot be climbed, and elevated access needs the owner's fall-protection and lockout procedures. Industrial tideflats sites often require hot-work and confined-space permits, and some call for respirators or other protective equipment, all of which should be settled when the scope is quoted.
Insulated and coated lines need to be opened at test points, and marine coatings may need to be removed locally to give the probe a clean surface. Agreeing who removes and restores them, and who provides lifts or staging, is where most schedule time is saved.
UT, MT or PT for your Tacoma work
Use ultrasonic testing to measure remaining wall and to check welds for flaws below the surface. Use magnetic particle inspection in Tacoma for surface cracks in carbon-steel welds, crane lugs and connection details, and liquid penetrant testing in Tacoma for stainless steel and aluminum. A common sequence on a waterfront structure is a thickness survey to find thinned members, then a surface method on adjacent welds and a shear-wave scan on any repair. For general background, see our ultrasonic testing services overview, and for the state, the inspection services in Washington page.
Training your own technicians
Employers who want their own UT staff can look at UT Level 1 training, UT Level 2 training and the ultrasonic testing simulator. For delivery in the area, see NDT training in Tacoma. A written practice under SNT-TC-1A is the employer's document, and we can draft or review one through written practice development or Level III consulting.
Corrosion under insulation and under coatings
Much of the steel around the bay is wrapped or painted, and the damage that matters most is often hidden. Insulated piping and tanks in the Pacific Northwest collect moisture where jacketing is damaged, at supports and at penetrations, and corrosion under insulation can run unseen for years. Ultrasonic thickness surveys are one of the few practical ways to look for it without stripping an entire line: the owner opens windows in the insulation at a sampling of locations chosen for risk, the technician measures and records, and the results decide whether more windows are needed. Painted waterfront steel is handled similarly, with coating thickness and surface condition noted so that the reading is trusted.
A sound survey plan names the locations, states the minimum readings that trigger further work, and says how new data will be compared with earlier readings. Matching the grid to the previous campaign matters, because corrosion rate is calculated from two readings at the same point taken at different times.
Recording and comparing thickness data over time
A single set of readings is useful; a series is much more so. Each location should have a stable identifier, a marked test point or a documented position, and a record of the probe and calibration so that later surveys can reproduce it. When the owner keeps readings in a spreadsheet or inspection database, Atlantis can deliver the data in the layout that system expects, which saves transcription errors and lets the inspector see rates at a glance.
What to send before a Tacoma survey
Good scoping saves a mobilization. Send isometrics or equipment drawings with the test locations marked, the nominal and minimum required thickness for each component, the operating temperature range, whether insulation or coating must be opened, and how the crew will reach elevated points. If you already hold earlier readings, include them so the new grid can match the old one.
Frequently asked questions
Can you examine container crane structures at the Port of Tacoma?
Atlantis can perform ultrasonic thickness and weld examination on crane girders, legs and frames when the owner arranges access, permits and a crane outage. We name no terminal as a client; scope, access rules and acceptance criteria come from the owner.
Why does salt air matter for ultrasonic thickness surveys in Tacoma?
Marine air speeds external corrosion at column bases, bolted joints and beneath coatings or insulation. Surveys therefore use tighter reading grids at splash and drip zones, and coatings often need local removal so the probe contacts clean metal.
Do you provide inspectors for API 510, 570 or 653 work?
No. The owner's authorized inspector is responsible under those codes. Atlantis performs the ultrasonic examination at the condition monitoring locations and supplies thickness data and a report the inspector can rely on.
Can UT replace radiography on a weld in Washington?
Sometimes, where the construction code allows and the owner, engineer and authorized inspector agree beforehand. ASME Section VIII, B31.3, AWS D1.1 and API 1104 differ, so the substitution is written into the procedure before scanning begins.
What information do you need to quote a Tacoma UT job?
Send component lists or drawings, material and nominal thickness, operating temperature, coatings or insulation, access method, governing code and edition, and acceptance criteria. For weld scans, include the joint design and the thickness range.
Does rain stop ultrasonic testing?
Light rain does not stop couplant-based testing, but wet electronics and slippery access do. Most Tacoma crews schedule exterior work for drier months and use shelters or tents for critical examinations.
What does Washington require of the people inspecting boilers and pressure vessels?
State inspectors hold a commission earned through the National Board exam and a Washington exam. Separately, Tacoma requires a license for boiler operators. The owner's inspector, not Atlantis, carries those responsibilities.
Who qualifies the technicians who travel to my site?
Atlantis qualifies its own technicians through a written practice modeled on ASNT SNT-TC-1A, so a Level II examiner runs the job and interprets what the instrument shows. An ASNT Level III signs off the procedure and checks the finished report, and qualification files can be attached to your quote.
Inspection and training around Tacoma
- Magnetic particle inspection (MT) in Tacoma
- Liquid penetrant testing (PT) in Tacoma
- Ultrasonic inspection services
- NDT inspection services in Washington
UT by industry for Tacoma: Marine & Shipbuilding · Pulp & Paper.
UT by job: Ultrasonic pipe thickness testing · Ultrasonic weld inspection · Ultrasonic boiler tube thickness testing · Ultrasonic testing of castings and forgings.
Training your own technicians: UT Level 1 training · UT Level 2 training · NDT training for Tacoma technicians.
Request an UT inspection quote for Tacoma
Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for ultrasonic testing in Tacoma.
Need ultrasonic testing (UT) done, or learned?
Atlantis provides ultrasonic testing (UT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.