Ultrasonic Testing (UT) Inspection in Shreveport, Louisiana
Atlantis NDT performs ultrasonic thickness testing and ultrasonic weld examination at industrial sites around Shreveport and Bossier City: storage tanks, process and gas piping, pressure vessels, structural steel and the heavy equipment that serves the Red River port. Technicians are mobilized to your site with flaw detectors, thickness gauges, probes and calibration blocks, work to a written procedure, and report readings against the code you name. Request an ultrasonic testing quote and we reply within one business day.
Where ultrasonic testing is used in Shreveport
Shreveport grew up on petroleum, natural gas, chemicals and iron and steel products, and it sits at the head of navigation on the Red River, where the Port of Caddo-Bossier covers roughly five thousand acres with interstate and rail access. That mix produces a steady list of ultrasonic work. Natural gas gathering, compression and treating facilities serve the Haynesville play that centers on northwest Louisiana and east Texas, and every one of them has piping, separators and bottles whose walls thin from internal corrosion. Storage tanks at terminals and process plants need floor and shell readings. Barksdale Air Force Base in Bossier City and the industrial parks around it add structural steel, support equipment and fabricated assemblies.
Typical ultrasonic jobs for this area include:
- Wall thickness grids on aboveground tank shells and roofs, and spot readings on tank floors from the outside where access allows.
- Thickness readings at condition monitoring locations on gas and liquid piping, including elbows, tees and dead legs where corrosion concentrates.
- Remaining wall on pressure vessels, separators and compressor scrubbers ahead of an inspection interval decision.
- Angle-beam examination of groove welds on new fabrication, repair welds and structural connections.
- Thickness checks on barge-loading and port handling equipment, crane booms and pressure-containing skids.
- Lamination checks on plate before welding, and baseline readings on new piping for the owner's records.
What ultrasonic testing finds, and what it misses
A transducer sends a short pulse of sound into the steel through a couplant, and the instrument displays the echoes that return. Timing a back-wall echo gives thickness. An echo that arrives early from inside the metal points to a reflector such as a lamination, a void or a planar flaw in a weld. The method sees volume, which makes it the standard answer to the question of how much wall is left, and it can size and locate planar flaws that a surface method cannot reach.
It has limits that matter on Shreveport equipment. A rough, scaled or heavily pitted surface scatters the sound and gives unstable readings, so surface preparation is part of the job. Coarse-grained cast or weld metal attenuates the beam. Very thin wall, and flaws oriented parallel to the beam, are easy to misread. Pitting is the classic trap: a gauge that sits on a high spot between pits reports a healthy wall that is not representative, so the technician scans an area and records the lowest reading instead of a single point. Ultrasonics also cannot tell you whether a flaw is cracking from fatigue or a fabrication defect without the technician reading the echo pattern and the weld geometry.
Codes and acceptance criteria for Louisiana work
The method is defined by the codes that call for it. ASME Section V Article 5 covers ultrasonic examination of materials, Article 4 covers welds, and Article 23 carries SE-797 for contact pulse-echo thickness measurement. ASTM E797 is the matching practice in general industry, and ASTM E164 covers contact examination of weldments. For weld acceptance the technician applies the construction code: ASME Section VIII Division 1 Appendix 12 for vessels, ASME B31.3 for process piping with its Table 341.3.2, AWS D1.1 for structural steel, and API 1104 for pipeline welds.
For in-service equipment, API 510, API 570 and API 653 put the inspection program under the owner's authorized inspector, who decides intervals and fitness for continued service. Atlantis supplies the examination data, not the inspector of record. At the state level, the Office of State Fire Marshal's Boiler Inspection Section administers the Louisiana boiler and pressure vessel rules and adopts the ASME Boiler and Pressure Vessel Code as the state construction code, so repair and alteration records for jurisdictional vessels need to sit comfortably beside the readings we hand over. Gas and liquid pipelines fall under PHMSA's 49 CFR Parts 192 and 195, and plants with highly hazardous chemicals work under OSHA's process safety management rule, 29 CFR 1910.119, whose mechanical integrity element calls for inspection to recognized good practice.
Technique: thickness surveys and weld examination
Thickness work starts with a dual-element probe, because its separate transmit and receive crystals cope with corroded, pitted surfaces better than a single-element probe. The technician calibrates on a step block made of the same material, checks the zero and velocity, and verifies calibration again at the end. On pitted or thin wall the A-scan display is watched, not just the digital number, so a doubled echo or a premature signal is caught. Hot surfaces need a high-temperature probe and couplant, plus a temperature correction. Readings are taken at marked locations on a grid so the next survey can repeat them and the corrosion rate can be calculated.
Weld examination uses angle-beam shear wave probes, commonly at forty-five, sixty and seventy degrees, matched to the thickness and joint. A reference level or distance-amplitude curve is built from side-drilled holes in a calibration block, and the technician scans both sides of the weld, from the weld face or the base metal, looking for lack of fusion, cracks, slag and porosity. Indications above the reporting level are located, evaluated for length and amplitude, and compared with the acceptance criteria. Our ultrasonic testing guide and the national UT service page go deeper into probe selection.
Who performs the work
The people who run the instruments are qualified through Atlantis's written practice, built on ASNT SNT-TC-1A. A Level II technician sets up and calibrates the instrument, performs the examination and interprets the results; an ASNT Level III approves the procedures and reviews reports. Under that recommended practice the employer certifies its own personnel, which is why we keep the written practice available to customers who want to audit it. Atlantis has no office in Shreveport. Technicians travel to your site for the agreed scope, and any plant orientation, badging or site safety training you require is built into the plan before they arrive. Procedures are written to the code on your purchase order and, where you have your own, we work to yours after review. See written practice development and Level III consulting for the oversight side.
What the UT report contains
A usable ultrasonic report lets someone who was not on the site understand and repeat the work. Ours identifies the component by tag or line number, the procedure and revision, the code and acceptance criteria, the instrument, probes, couplant and calibration block, and the calibration checks. It names the technician and certification level, records surface condition and temperature, and states the examination date and the extent covered.
For thickness surveys the report includes a sketch or grid with every reading, the nominal and minimum required wall where you supply them, and flags for readings under the threshold. For weld examination it lists each recordable indication with position, length, depth and amplitude, then states accept or reject against the named criteria. Calibration and reference blocks are tied to the report, so the data stays defensible when an authorized inspector, an insurer or an auditor reviews it months later.
Sizing a survey so the data is worth having
A thickness survey is only as useful as its repeatability. Before we mark a single reading we agree on the location scheme with you: how many readings per elbow, how a tank shell is divided into courses and grids, and how floor plates are numbered. Where earlier surveys exist we reuse their locations so the corrosion rate comes from like-for-like readings rather than a fresh pattern. Where they do not, the first survey becomes the baseline, and the layout is written into the report so the next technician can follow it without guessing.
Planning a UT job in Shreveport
Summers around Shreveport are hot and humid, and a steel shell in direct sun can reach temperatures where ordinary couplant dries out and standard probes wear quickly, so we plan surface temperature, probe selection and shade before the first reading. Spring storms and sustained rain bring delays on outdoor tank and pipe rack work, and winter cold snaps affect couplant and instrument performance, so schedule slack is worth building in. Plants and terminals each have orientation, permit and lockout requirements, and port-side work involves coordination with the facility on access and vessel movements.
Insulation removal, scaffolding and surface cleaning are usually the long poles in a thickness survey, so confirm who provides them. Send us the equipment list, the drawings or datasheets, the previous survey readings and the governing code. We then propose the scope, the number of readings and the format of the report. Work around planned outages is common, and an early request lets the scope be fixed before turnaround contractors crowd the site.
UT, MT or PT for your job in Shreveport
Choose the method by the question. If you need remaining wall, corrosion rate or the volume of a weld, ultrasonics is the answer. If you need to know whether a ferromagnetic weld toe or lug has a surface crack after fabrication or repair, magnetic particle inspection in Shreveport is faster and more sensitive at the surface. If the material is stainless steel, aluminum or another non-magnetic alloy and you suspect a surface-breaking flaw, liquid penetrant testing in Shreveport is the fit. Many repair packages use two of them together: ultrasonics to confirm remaining wall and weld soundness, then a surface method on the final weld. Ask us what your code requires and we will say which method it names.
You can also read about the wider inspection services across Louisiana.
Training your own UT technicians
If you would rather build in-house capability, Atlantis runs UT Level 1 training and UT Level 2 training, and the Practical NDT ultrasonic simulator lets trainees practice scanning before they touch real equipment. Your company then certifies its own staff under its written practice. For local interest in qualification, see NDT training for Shreveport.
Frequently asked questions
What does ultrasonic thickness testing measure on Shreveport tanks and piping?
It measures the remaining wall of steel by timing the echo from the back wall. Readings are taken on a marked grid or at condition monitoring locations so the owner can compare surveys over time and calculate a corrosion rate for each tank, line or vessel.
Can you inspect welds ultrasonically, or only measure thickness?
We do both. Thickness gauging uses dual-element probes, and weld examination uses angle-beam shear wave probes with a reference level built from side-drilled holes. Weld indications are judged against the acceptance criteria of the construction code that applies to the job.
Do I need to prepare the surface before ultrasonic testing?
Yes. Loose scale, paint blisters and heavy rust interfere with coupling and can make readings unstable. At minimum the contact area should be wire-brushed or ground smooth. Tell us the condition in advance and we will plan cleaning or confirm who will remove coatings and insulation.
Is ultrasonic testing useful on hot equipment?
It can be. High-temperature probes and couplant allow readings on warm surfaces, with a correction applied for temperature. Very hot lines may need to be examined for short contact periods or after cool-down, and we agree the limits with the owner before the work.
Which codes do you use for UT acceptance?
We use whatever the construction code or owner specification names, such as ASME Section VIII Division 1, ASME B31.3, AWS D1.1 or API 1104 for welds, with ASME Section V Article 4 or Article 5 governing the technique. For thickness there is usually a minimum required wall rather than a flaw criterion.
Do you act as the API authorized inspector?
No. Under API 510, 570 and 653 the owner's authorized inspector is the inspector of record and decides intervals and fitness for service. Atlantis supplies the ultrasonic data, calibration records and the report that inspector relies on.
Does Atlantis have an office in Shreveport?
No. Atlantis has offices in Houston and Hyderabad, and technicians are mobilized to your Shreveport or Bossier City site for the agreed scope. Orientation, badging and access requirements are planned with you before anyone travels.
What documents should I send for a UT quote?
Send the equipment list or line list, the governing code, drawings or datasheets, nominal and minimum wall values, access constraints and any earlier thickness data. With that we can propose the scope, the number of locations and the report format. We reply within one business day.
Can my own staff learn ultrasonic testing through Atlantis?
Yes. Atlantis offers UT Level 1 and Level 2 training and a Practical NDT simulator for practice. Under SNT-TC-1A your company certifies its own personnel, using its written practice, once the training and experience requirements are met.
Inspection and training around Shreveport
- Magnetic particle inspection (MT) in Shreveport
- Liquid penetrant testing (PT) in Shreveport
- Ultrasonic inspection services
- NDT inspection services in Louisiana
UT by industry for Shreveport: Pipeline · Oilfield & Drilling · Pulp & Paper.
UT by job: Ultrasonic pipe thickness testing · Ultrasonic weld inspection · Ultrasonic boiler tube thickness testing · Ultrasonic testing of castings and forgings.
Training your own technicians: UT Level 1 training · UT Level 2 training · NDT training for Shreveport technicians.
Request an UT inspection quote for Shreveport
Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for ultrasonic testing in Shreveport.
Need ultrasonic testing (UT) done, or learned?
Atlantis provides ultrasonic testing (UT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.