Atlantis NDT mobilizes ASNT SNT-TC-1A qualified technicians to New Orleans area sites for ultrasonic thickness testing, corrosion surveys and ultrasonic weld examination. The work usually involves piping, tanks, pressure vessels and structural steel along the Mississippi River corridor, at terminals and at industrial plants. Send the drawings, the governing code and the measurement locations, and we reply within one business day. Request a UT quote for New Orleans.

Why ultrasonic testing matters in the New Orleans area

New Orleans sits on a deepwater river port close to the Gulf of Mexico. Port NOLA describes itself as the only deepwater container port in Louisiana, with six dedicated breakbulk terminals and rail service from six Class I railroads, and Britannica notes that petrochemical plants line the Mississippi above the city. The area is also known for barge traffic, grain and chemical exports, and, at the Michoud Assembly Facility east of the city, large aerospace structures. All of that rests on steel: dock piping, tank farms, loading arms, process lines, vessels, barges and the structures that carry them.

The Gulf Coast climate is hard on steel. Warm, humid air, salt carried inland by storms and long wet seasons keep carbon steel corroding, and low-lying ground keeps equipment in a moist environment. For owners, the question that follows is simple: how much wall is left, and how fast is it going? Ultrasonic thickness testing answers that question without cutting or shutting down a line, which is why it is a routine part of mechanical integrity programs in the region.

What ultrasonic thickness readings reveal and where they mislead

A probe sends a pulse into the wall and the instrument times the echo from the far side, converting it to thickness using the sound velocity of the material. Measured at set locations over time, the readings give a corrosion rate and a remaining life estimate. They also show unexpected behavior: a location that thins faster than its neighbors points to turbulence, a dead leg, or a coating failure nearby.

Several limits apply. Corrosion under insulation is common in humid climates, but a probe cannot read through insulation, so access means removing small windows in the jacketing and insulation and closing them properly afterward. Scale and heavy tuberculation make coupling unstable. Pitting can hide between readings, so suspect areas call for a closer grid or scan. Laminations in plate produce shallow readings that are real reflectors and not a thin wall. And thickness readings do not find surface cracks; for those, magnetic particle testing or penetrant testing is the right tool, as covered on our New Orleans MT page and New Orleans PT page.

Tank farms and terminals deserve a specific mention. On aboveground storage tanks, ultrasonic readings on shell courses, roof plate, nozzles and the annular ring feed the owner's API 653 program, while the owner's inspector decides intervals and fitness. A thickness probe samples only the points it touches, so a floor with extensive pitting needs a broader evaluation strategy chosen by the owner and the inspector. Dock and loading-rack piping, which sees frequent product changes and wet weather, is another place where a routine set of marked points pays for itself over several campaigns.

Ultrasonic weld examination

Weld examination uses an angle-beam shear-wave probe at 45, 60 or 70 degrees, scanned from the weld's sides, with sensitivity set from a reference level or a distance-amplitude curve built on side-drilled holes. The technician looks for lack of fusion, incomplete penetration, cracks and slag, then records each reflector by location, length and amplitude. Acceptance comes from the construction code: a given reflector may pass one document and fail another.

Honest coverage statements matter. Thin wall, tight fillets, nozzle geometry and coarse-grained castings limit what the beam can see. If a weld cannot be fully scanned, the report names the uncovered area instead of implying it was examined. Where a code allows ultrasonic examination in place of radiography, that choice should be agreed with the owner, the engineer and the authorized inspector before work begins.

Codes that govern New Orleans UT work

For new pressure equipment, ASME Section V Article 4 covers ultrasonic examination of welds and Article 5 covers materials, while Article 23 contains SE-797 for contact thickness measurement. ASME Section VIII Division 1 Mandatory Appendix 12 is the ultrasonic examination of welds in vessels. ASME B31.3 paragraph 344.6 describes ultrasonic examination of process piping welds, with acceptance in Table 341.3.2, and ASME B31.1 applies to power piping. AWS D1.1 covers structural steel and its own ultrasonic acceptance criteria for groove welds.

In service, API 510 governs pressure vessels, API 570 governs piping, and API 653 governs aboveground storage tanks, all with the owner's authorized inspector responsible for the program, while Atlantis supplies the thickness and weld data. API 1104 covers pipeline welding, and PHMSA rules in 49 CFR Parts 192 and 195 apply to gas and liquid pipelines. For process facilities, OSHA 29 CFR 1910.119(j) requires inspection and testing consistent with recognized and generally accepted good engineering practice. ASTM E797 is the practice for contact thickness measurement and ASTM E164 for contact ultrasonic examination of weldments.

How Louisiana regulates boilers and pressure vessels

Louisiana's boiler law gives the assistant secretary of the Office of State Fire Marshal, Code Enforcement and Building Safety, authority to investigate boiler matters, adopt rules for construction, installation, repair and operation, and issue orders to enforce them. The rules generally follow the ASME boiler construction code, and boilers and pressure vessels that require ASME stamping are inspected under the ASME Code and National Board standards.

That means the state-side record for a vessel or boiler typically comes from a commissioned inspector, not from us. Atlantis does not act as that inspector. What a UT survey contributes is evidence: thickness at agreed locations, mapped and dated, that the owner, the insurer's inspector or the state can read. Ask your inspector what locations and format they want before the job, and put that in the request.

How a thickness survey is performed

The technician calibrates on a step block of matching material, with steps bracketing the expected wall. For corroded or rough surfaces a dual-element probe is the norm because it reads through pitting better than a single crystal. An A-scan view is used so doubled echoes and laminar reflections can be recognized instead of recorded as false thickness. On hot lines in Gulf Coast summer, a high-temperature probe and couplant are required, with the velocity corrected for the surface temperature where the procedure calls for it.

Points are laid out on an isometric or marked on the component, and the same points are re-read in later campaigns so corrosion rate is calculated from like-for-like data. At each point the surface condition is noted, and any reading below the stated minimum is flagged immediately for the owner. Insulation windows are cut, read and resealed, with the sealing method noted so the owner's weather protection stays intact.

Who does the work

Atlantis has no office in New Orleans. Our technicians travel to your site for the agreed scope and are qualified under the company's written practice to ASNT SNT-TC-1A: a Level II performs and interprets, and an ASNT Level III approves procedures and reviews reports. On Louisiana work the approving Level III is Anoop Rayavarapu, who holds ASNT NDT Level III in UT, RT, MT, PT and VT. Record-keeping follows the written practice, and qualification records can be reviewed by the owner on request. Both ISO 9001 and ISO 14001 certificates are held by Atlantis.

If a terminal, plant or contract requires a specific qualification route, or a procedure approved by your own Level III, say so in the request. It changes the quote and the preparation, and it is much easier to address before travel than on the day.

What the UT report contains

Planning a UT job in New Orleans

Summer heat and humidity drive the schedule. Steel in direct sun runs far hotter than the air, so high-temperature probes, shade and early starts matter, and technicians need heat-stress breaks. Rain and thunderstorms can stop outdoor and elevated work quickly, and hurricane season, from June through November, can interrupt any plan, so flexible mobilization dates are sensible. Wet surfaces dilute couplant and make cleaning harder, so dry-off time belongs in the plan.

Site access is the other major factor. River terminals, docks and plants typically require TWIC or site badging, safety orientation and permits for confined space or hot work nearby, and turnaround seasons fill local lodging and contractor capacity. Tell us the facility type, badge requirements, working window and who controls access, and travel and equipment will be planned from that. Mention whether insulation must be removed and who will do it.

Because low ground and levee-protected sites keep water close, some New Orleans plants treat flooding and storm surge as a planning item. After a flood or a major wind event, owners often order a post-event thickness and weld check on exposed piping supports and shell plate. Having baseline readings from earlier campaigns makes that comparison meaningful, which is one more reason to keep the marked-point layout consistent.

UT, MT or PT for your New Orleans job

Use ultrasonic testing for wall thickness and internal weld flaws. Use magnetic particle inspection for surface and near-surface cracks in carbon and low-alloy steel, such as crane welds and repair welds. Use dye penetrant inspection for surface cracks in stainless and other non-magnetic metals, common in chemical service. Many New Orleans scopes combine two or three methods. For background, read the national ultrasonic testing page, the ultrasonic testing guide, the Article 5 thickness requirements explainer, and the Louisiana inspection hub.

Training your own UT technicians

If you would rather build your own team, Atlantis offers UT Level 1 training and UT Level 2 training, with the ultrasonic testing simulator for practice, plus the ultrasonic testing training overview. Qualification itself is the employer's job under SNT-TC-1A, so supervised experience hours remain necessary. Local details are on the New Orleans NDT training page, and if your written practice needs work, see written practice development.

Frequently asked questions

What does a UT thickness survey in New Orleans involve?

A technician calibrates on a matching step block, reads thickness at marked locations, records surface condition, and flags any reading below the minimum. The report lists the data in a table that can be compared with earlier campaigns.

Can ultrasonic testing be done through insulation?

No. The probe needs bare metal, so small windows are cut in the jacketing and insulation, readings are taken, and the windows are resealed. Agree who will remove and restore insulation before the job.

What is the difference between UT thickness testing and UT weld inspection?

For thickness, a straight-beam probe measures the remaining wall. Weld inspection uses an angle-beam shear-wave probe to look for internal flaws like lack of fusion, judged against code acceptance criteria.

Which code applies to my tank or vessel in Louisiana?

In service, API 653 covers aboveground tanks, API 510 covers pressure vessels and API 570 covers piping. Louisiana's boiler rules follow ASME and the National Board, with the State Fire Marshal's office as the authority.

How do hurricane season and heat affect scheduling?

Storms can halt outdoor and elevated work with little notice, and summer sun heats steel past what standard probes handle. We plan flexible mobilization dates, high-temperature probes and shaded or early work.

Does Atlantis have a New Orleans office?

No. Technicians travel to your site for the agreed scope. We quote travel from the job details and do not promise an arrival time before access, badging and scope are confirmed.

Can UT replace radiography on pipe welds?

In some cases, when the construction code and the owner both permit it. ASME B31.3 and API 1104 contain ultrasonic provisions, but the swap must be agreed with the owner, engineer and authorized inspector before work starts.

What access items should I arrange before a New Orleans UT job?

Site badging or TWIC, safety orientation, hot-work or confined-space permits, scaffolding or lift access, and removal of insulation windows. Telling us these up front lets us plan travel and equipment accurately.

Who qualifies your ultrasonic technicians?

Atlantis' written practice, based on ASNT SNT-TC-1A, governs qualification, with a Level II performing the exam and an ASNT Level III approving procedures. If your contract requires another scheme, state it in the request.

Can my staff learn UT instead of hiring a crew?

Yes. UT Level 1 and Level 2 training and a simulator are available. Your employer's written practice sets qualification and the supervised experience hours required before independent work.

Inspection and training around New Orleans

UT by industry for New Orleans: Petrochemical · Offshore · Marine & Shipbuilding.

UT by job: Ultrasonic pipe thickness testing · Ultrasonic weld inspection · Ultrasonic boiler tube thickness testing · Ultrasonic testing of castings and forgings.

Training your own technicians: UT Level 1 training · UT Level 2 training · NDT training for New Orleans technicians.

Request an UT inspection quote for New Orleans

Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for ultrasonic testing in New Orleans.

Need ultrasonic testing (UT) done, or learned?

Atlantis provides ultrasonic testing (UT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.