Ultrasonic Testing (UT) and Thickness Inspection in Jacksonville, Florida

Atlantis NDT provides ultrasonic testing in Jacksonville, Florida, covering wall thickness surveys on tanks, vessels, piping and ship structure and ultrasonic examination of welds. Work is carried out for terminals along the St. Johns River, shipyards and repair berths, industrial plants and steel structures across Duval County. Technicians travel to your site for an agreed scope. Describe the components in the UT inspection quote form and we reply within one business day.

Where ultrasonic testing is used in Jacksonville

Jacksonville's economy is built around the river and the port. JAXPORT's marine terminals at Blount Island, Talleyrand and Dames Point handle containers, vehicles, heavy lift, breakbulk steel and paper, forest products and liquid bulk such as molasses and vegetable oils, and the harbor also holds more than twenty privately operated facilities including drydocks and petroleum terminals. The city also hosts major military installations. Every one of those activities depends on steel that corrodes in a warm, wet, brackish environment.

Brackish water makes the picture more severe than a freshwater site. The St. Johns River is tidal for a long way upstream, and splash zones, pilings, ballast tanks and the lowest courses of shoreline tanks all see wet-dry cycles that attack coatings and steel unevenly.

What ultrasonic testing finds and what it misses

UT works by sending a short pulse of high-frequency sound into steel and timing its echo from the back wall or from a flaw. For corrosion work it gives remaining wall thickness at a point. For welds, an angled beam passes through the volume of the joint and reports reflectors such as lack of fusion, incomplete penetration, cracks and slag inclusions.

The technique is strong where access is good and the surface is sound, and weaker in other conditions. A pitted or heavily scaled surface may need cleaning before the probe will couple. A coating that has disbonded from the steel can hide a thin spot, since sound reflects at the gap. A single reading can miss a local pit between two points, so grids are sized to the corrosion pattern expected. Coarse-grained castings and some stainless welds scatter sound and reduce what can be reliably examined. When the beam cannot cover part of a joint, the report states the uncovered portion rather than implying full coverage.

Codes and acceptance criteria used in Jacksonville

The procedure is based on ASME Section V. Article 4 covers ultrasonic examination of welds, Article 5 covers materials, and thickness measurement appears in SE-797, which is in Article 23. The accept or reject limits come from the code that governs the item:

  1. Vessels built to ASME Section VIII Division 1 use Mandatory Appendix 12 for ultrasonic examination of welds.
  2. Process and power piping fall under ASME B31.3 (examination in paragraph 344.6, criteria in Table 341.3.2) or ASME B31.1.
  3. Aboveground storage tanks in service are inspected under API 653, supported by API RP 575 for storage tank practices.
  4. Structural steel is examined under AWS D1.1 for buildings and AWS D1.5 for bridges, which is the code that state transportation agencies apply to steel highway bridges.
  5. ASTM E797 describes contact pulse-echo thickness measurement, and ASTM E164 covers contact ultrasonic examination of weldments.

The owner's authorized inspector is responsible for inspection under API 510, 570 and 653; Atlantis gathers the thickness and weld data and reports it. In Florida the state boiler law, chapter 554 of the Florida Statutes, adds certificate inspections for covered boilers through the Department of Financial Services, and UT results on a boiler are data for that inspector.

How the thickness survey is run

The job starts with a scope: which lines, vessels or tank courses, and at which locations. A grid or condition monitoring location list is established from drawings and, where available, earlier survey data, so the same points are measured again. On the day of the work the instrument is calibrated on a step block of matching material. For corroded steel a dual-element probe is used, and the technician reads the A-scan instead of a bare digital number, which avoids errors on thin or pitted wall, including a reading that is double the real thickness.

Hot lines call for a high-temperature probe and couplant and a correction for temperature. Tank shells in Jacksonville summers are warm to the touch, and surfaces in sun are hotter. The procedure sets limits and corrections for these conditions, and the calibration is checked again at intervals through the shift and at the end.

How welds are examined

Weld examination uses shear-wave angle-beam probes, with angles such as 45, 60 and 70 degrees chosen for the thickness and joint type. A reference level or a distance-amplitude curve is built from side-drilled holes in a calibration block. The technician scans along and across the weld, evaluates any indication against the curve and records its length, depth and position. Planar flaws such as cracks and lack of fusion are judged against stricter limits than rounded flaws. For critical welds the procedure specifies a scan from both sides and the weld surface condition required.

Weld caps that are rough or reinforcement that is high can prevent a proper scan, and the owner may need to dress the weld. The scope can allow for light grinding to be done by others before the examination.

Who does the work and under what rules

Level II technicians perform and interpret the examination under Atlantis's written practice, which follows ASNT SNT-TC-1A. An ASNT Level III approves procedures and reviews reports. Level III oversight comes from Anoop Rayavarapu, ASNT NDT Level III in UT, RT, MT, PT and VT, and the company is certified to ISO 9001 and ISO 14001. If a shipyard, terminal operator or customer requires its own written practice or procedure format, written practice development or Level III consulting can align the paperwork before work begins.

Hull plate, ballast tanks and other ship-side work

Ship repair in the harbor adds a thickness job that land plants rarely see. Hull plating wastes unevenly: the waterline belt, the bottom plating over ballast tanks, the plating around sea chests and the tank boundaries below cargo spaces all lose steel at different rates. A hull gauging plan therefore follows the ship's own structure, with readings taken on each plate between frames and across the stiffeners, so the renewal decision rests on the plates that are actually thin and not on an average.

Gauging is usually done after the surface has been cleaned by the yard, and from inside ballast tanks the work is a confined space job with ventilation, gas tests and a standby person. Readings from a tank's bottom plates, for example, are taken from inside while the vessel is afloat or docked. The report is organized by frame and plate so that the repair supervisor can mark up renewals directly from it. Class society surveys are a separate matter from an owner's own condition gauging, and the owner or the society decides what each reading is used for.

Bridges, girders and fracture-critical steel

Jacksonville sits on a river with many crossings, and steel highway and rail structures there are examined under bridge-specific rules. Ultrasonic examination of bridge steel is usually applied to groove welds in girders and to repair welds, and thickness readings check section loss on flanges, webs and bearing stiffeners where water collects. The owner's bridge program, not the inspection firm, determines which members are fracture critical and how often they are visited. Lane closures, rigging and traffic control are the owner's to arrange, so the plan should allow time for them before technicians mobilize.

What the report gives you

A UT report identifies each component and location, then lists the procedure and revision, instrument, probes, calibration blocks and calibration checks, surface condition and temperature, and the technician and level. Thickness is reported by location in a table or on a grid sketch with nominal and minimum required values for comparison, so loss rates can be calculated. Weld indications are listed with position, length, depth and amplitude and given an accept or reject decision against the named criterion. Limitations, such as an area that could not be reached, appear in plain words. A tank or hull report often includes a plate map so renewals can be planned from it.

Planning a UT job in Jacksonville

Jacksonville weather and logistics shape the work. Summers are hot and humid with frequent afternoon thunderstorms, and lightning stops work at height or on tank roofs. Hurricane season runs from June to November, and the river and port close to traffic during storms, which can reshuffle access to terminals and drydocks. Winters are mild, so cold is rarely a limit.

Access takes planning. Port terminals need identification and orientation, shipyards and drydocks have their own safety rules, and tanks and confined spaces need permits and gas tests. Ship work is usually scheduled around the vessel's time alongside, so a UT plan agreed before the vessel arrives gives the repair team data when they need it. Atlantis has no office in Jacksonville; technicians are mobilized from outside the area and travel is part of the quote.

UT, MT or PT for your Jacksonville job

If the question is wall loss or an internal weld flaw, UT is the method. If the question is a surface crack in carbon steel, magnetic particle inspection in Jacksonville is faster. If the metal is stainless or aluminum, or you need to find any surface-breaking flaw, choose liquid penetrant testing in Jacksonville. The national ultrasonic testing page and the Florida inspection hub give more context, and the ultrasonic testing guide explains the method in depth.

Building your own UT team

Owners with a steady workload may prefer in-house inspectors. UT Level 1 and UT Level 2 courses are available, with a browser UT simulator for practice and a page on NDT training in Jacksonville. Under SNT-TC-1A your company certifies the technician after the training and experience hours are met.

Frequently asked questions

Does Atlantis staff an office in Jacksonville?

No. Atlantis has no office in Jacksonville. Technicians are mobilized to your terminal, yard, plant or project site for the agreed scope, and travel is included in the quote. We reply within one business day.

Can UT be done on a ship while it is in a Jacksonville drydock or alongside?

Yes, subject to access and safety rules. Hull plate and tank boundary readings can be taken once surfaces are cleaned and staging is in place. The vessel schedule normally sets the window, so share it with the request.

How is thickness measured on a brackish-water tank or piling?

Surface scale and marine growth are removed, a couplant is applied and a dual-element probe is read against a calibrated step block. Pitted areas are checked on the A-scan so that false readings are caught.

Which standards apply to UT weld examination on structural steel?

Technique follows ASME Section V Article 4. For buildings the acceptance criteria are in AWS D1.1, while AWS D1.5 governs steel highway bridges. Pressure vessels and piping use ASME Section VIII or B31.3.

Does UT replace the Florida boiler inspection?

No. Covered boilers receive certificate inspections under Florida chapter 554 from certified boiler inspectors. UT thickness data supports the inspector and the owner but is not a statutory inspection.

What happens when a thickness reading is below the minimum?

The reading is reported straight away to your authorized inspector or engineer, with its location and the surrounding readings. The owner decides on repair, derating or a shorter inspection interval; Atlantis supplies the evidence.

Does Atlantis serve as the API 653 inspector of record?

No. The owner-appointed authorized inspector remains inspector of record under API 653. Atlantis carries out the ultrasonic examination and gives that inspector the thickness data and records.

What should I send to get a UT quote in Jacksonville?

List the components, materials, thicknesses, operating temperature, coating, access method, governing code and any site or vessel schedule. Send them through the quote form and we reply within one business day.

Inspection and training around Jacksonville

UT by industry for Jacksonville: Marine & Shipbuilding · Rail · Pulp & Paper.

UT by job: Ultrasonic pipe thickness testing · Ultrasonic weld inspection · Ultrasonic boiler tube thickness testing · Ultrasonic testing of castings and forgings.

Training your own technicians: UT Level 1 training · UT Level 2 training · NDT training for Jacksonville technicians.

Request an UT inspection quote for Jacksonville

Send the component and material, the quantity, the code or specification and the site address. We reply within one business day with the scope, the mobilization plan and a quote. Request a quote for ultrasonic testing in Jacksonville.

Need ultrasonic testing (UT) done, or learned?

Atlantis provides ultrasonic testing (UT) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.