Radiographic Testing (RT) Support in Salt Lake City, Utah
Atlantis NDT does not perform radiographic testing in the United States, in Salt Lake City or anywhere else. Industrial radiography is a licensed activity: the Nuclear Regulatory Commission sets the rules in 10 CFR Part 34, and Utah, as an Agreement State, administers its own radiation control rules for the same work. We do not hold a source license and we do not offer to shoot film or images here. If you searched for RT in Salt Lake City, this page explains what Atlantis can do for you instead.
Why Atlantis does not offer radiography in Salt Lake City
Radiography uses sealed gamma sources or X-ray tubes, and the people who operate them must be licensed, trained as radiographers, and covered by a radiation safety program. Exclusion zones, source security and records are all regulated. A company that does not hold that license cannot lawfully offer the service, so Atlantis does not. If your specification requires radiography on a weld or casting, you will need a licensed radiography contractor, and the owner or the engineer should choose one against the contract requirements.
Ultrasonic testing as a volumetric alternative in Salt Lake City
Where the construction code and the owner allow it, ultrasonic examination can replace radiography for the volumetric check of a weld. ASME B31.3 and API 1104 contain provisions for ultrasonic examination of production welds, AWS D1.1 gives ultrasonic acceptance criteria for groove welds, and ASME Section VIII permits ultrasonic examination in place of radiography only under specific conditions. None of these substitutions is automatic. The owner, the engineer and, for code work, the authorized inspector agree before the job that ultrasonic examination is acceptable for the specific weld.
When that agreement exists, our Level II technicians travel to your site and perform shear wave examination to a procedure approved by an ASNT Level III. See ultrasonic testing in Salt Lake City for what the examination covers, and our national UT service for scope. Surface checks at the same weld are available as magnetic particle inspection and liquid penetrant testing.
Level III review of radiographs and RT procedures
Review work does not need a radiation license because no source is used. Our founder, Anoop Rayavarapu, is ASNT NDT Level III in UT, RT, MT, PT and VT, and Atlantis can support Salt Lake City owners with:
- Independent review of radiographs, in film or image form, and technique sheets against ASME Section V Article 2 and the construction code.
- A second read on disputed or borderline indications before a weld is cut out.
- Review of a radiography contractor's procedure and written practice before they begin work.
Send the images and the code through this radiograph review request and we reply within one business day. For program-level help, see Level III consulting and written practice development.
Radiography theory training
If your team wants to understand radiography, we teach the theory behind it, including image quality, exposure principles and interpretation, in RT Level 2 training. Theory instruction is not a substitute for a radiographer license or for employer-based certification, which remains with the employer under its written practice built on ASNT SNT-TC-1A.
Planning with Atlantis in Salt Lake City
Atlantis keeps no office in Salt Lake City. Technicians are mobilized from outside the city to your refinery, plant or shop for the agreed scope, and Level III review is done remotely from the images you send. Tell us the material, thickness, code and what the radiography contract requires, and we will say plainly which part we can help with.
Frequently asked questions
Why does Atlantis not perform radiographic testing in Salt Lake City?
No. Atlantis does not perform radiographic testing in the United States because it is a licensed activity under NRC rules in 10 CFR Part 34 or the equivalent Agreement State rules, and we do not offer it.
Can ultrasonic testing replace radiography on my weld?
Only when the construction code permits it and the owner accepts it. Get the engineer and authorized inspector to sign off on ultrasonic examination for that specific weld before the job, and have the procedure cite the governing code.
Can Atlantis review radiographs from another contractor?
Yes. An ASNT Level III can review radiographs and technique sheets against ASME Section V Article 2 and the construction code, and give a second read on disputed indications. No radiation license is needed for review work.
Does Atlantis teach radiography?
Atlantis teaches radiographic testing theory in its RT Level 2 course. The course does not license anyone to operate sources, and employer certification remains under the employer's written practice.
How do I request a Level III radiograph review?
Use the review request link on this page and attach images or describe the code and weld. We reply within one business day and say whether the review fits our scope.
Inspection and training around Salt Lake City
- Ultrasonic testing (UT) in Salt Lake City
- Magnetic particle inspection (MT) in Salt Lake City
- Liquid penetrant testing (PT) in Salt Lake City
Training your own technicians: UT Level 1 training · UT Level 2 training · NDT training for Salt Lake City technicians.
Need a weld examined in Salt Lake City?
Send the drawing or weld list, the material and thickness, and the code you work to. We will tell you whether ultrasonic testing can be used in place of radiography for that work, or quote a Level III review of radiographs you already have. Ask about UT or a radiograph review for Salt Lake City.