Maritime inspection · Sweden

Thickness Measurement for Crude and Product Tankers at Lysekil and Brofjorden

Lysekil, at the mouth of the Gullmarn fjord on the Bohuslän coast, matters to tanker operators because of Brofjorden, the deep-water harbour north of the town that serves Preemraff Lysekil, Sweden's largest refinery. Crude carriers discharge at its crude jetty and product tankers lift refinery output from the product berths. Calls are short and terminal rules are strict, so gauging is planned tightly around discharge, anchorage waits and the docking ahead. Atlantis sends its technicians from India for each tanker and they join her through the ship's agent.

Crude carriers at a very deep jetty

The crude berth at Brofjorden was built for the largest crude carriers, so Aframaxes, Suezmaxes and VLCCs all discharge there. While cargo pumps run, deck structure, void spaces and segregated ballast tanks certified for entry can be gauged, always within what the terminal and master allow.

Product tankers on repeat liftings

Product tankers come back to Brofjorden voyage after voyage to load refinery output. That rhythm lets an owner split a gauging programme over several calls, finishing a few ballast tanks each time, so that the full picture is ready before the ship goes to her renewal docking.

Waiting time at the Bohuslän anchorages

Tankers waiting for a berth lie at anchorage positions east of Bohus-Malmön, around Lindholmen or, for the largest ships, further offshore. A wait of a day or more, with the crew free to prepare spaces, suits deck and air-pipe gauging reached by launch.

Inspection services for ships at Lysekil

Each service has its own page with the method, the class requirements and what the report contains.

Ultrasonic Thickness Measurement (UTM)

Hull, tank, deck and bulkhead gauging recorded on the class thickness-measurement formats, with sketches and corrosion flagged against the allowable margins.

Explore

Special Survey Thickness Measurement

Gauging for the 5, 10, 15, 20 and 25-year special (renewal) surveys and intermediate surveys, plus pre-docking steel estimates.

Explore

CAS (Condition Assessment Scheme)

Thickness measurement and survey support for the IMO Condition Assessment Scheme, and what CAS asks of an older tanker today.

Explore

CAP Thickness Measurement

Gauging and close-up survey data for a Condition Assessment Programme, the voluntary class service charterers ask for on older tankers and bulk carriers.

Explore

ESP Gauging

Thickness measurement and close-up survey support for oil tankers, chemical tankers and bulk carriers under the ESP Code.

Explore

Hull Structural Integrity

Substantial and excessive corrosion, pitting, grooving, buckling and fatigue cracks, with magnetic particle and penetrant crack detection.

Explore

Ship Piping Inspection

Wall-thickness gauging of cargo, ballast, fuel, sea-water and fire-main piping, with minimum-wall checks and isometric sketches.

Explore

Scrubber Piping Inspection

EGCS wash-water and overboard discharge piping, the hull penetration area and scrubber welds, checked between dockings.

Explore

IHM (Inventory of Hazardous Materials)

IHM Part I surveys, sampling and maintenance for the EU Ship Recycling Regulation and the Hong Kong Convention.

Explore

Marine NDT Services

Every NDT method we use on ships, from visual inspection and MPI to PAUT and ACFM, chosen by the defect you are looking for.

Explore

Brofjorden and Lysekil: a refinery harbour on the Skagerrak coast

The Bohuslän coast is granite cut into fjords and sheltered by skerries, and Brofjorden is one of the inlets where deep water reaches close to the shore. That depth is why the refinery was sited here in the 1970s: the crude jetty near the mouth of the fjord has water enough for crude carriers of several hundred thousand tonnes deadweight, and the approach from the Skagerrak is short compared with most Baltic oil ports. Pilots from the Swedish Maritime Administration board south-west of the approach, larger ships take two pilots, and escort tugs are compulsory for laden crude tankers. Lysekil town itself lies to the south, on the peninsula at the entrance to the Gullmarn, with a harbour for small craft and a waterfront better known for summer visitors than for cargo.

Almost all the commercial shipping in the municipality belongs to the refinery. Crude arrives from the North Sea fields and from much further afield on Aframax, Suezmax and VLCC tonnage, and the refinery's petrol, diesel and other products leave on product tankers bound for Scandinavian, Baltic and wider European terminals. By tonnage handled, Brofjorden ranks among the busiest harbours in Sweden, and on most days several tankers are either alongside, approaching or at anchor. The ships are managed from all over the world, so a superintendent in Athens, Oslo or Singapore may need readings from a tanker that will spend only a day at the jetty, and Brofjorden is often the last European call before a long ballast voyage or a docking.

Weather sets the pace more than ice does. The fjord's shallow inner reaches can freeze in a hard winter, but the jetties and fairway remain in use, and the real constraint is the Skagerrak gale: in strong winds from the south-west round to the north, arrivals and departures are held and tug escorts are suspended, so a tanker may spend longer at anchor than planned. Short December daylight also limits outdoor deck work. Inspection demand reflects the trade. Tanker owners face vetting under SIRE 2.0 and charterers' age limits, so ballast tank coating condition, deck plating and the structure around manifolds and pipe supports are recurring subjects, and older ships approaching their third or fourth renewal survey often need a pre-docking steel estimate before the yard is booked.

Where a tanker can be gauged around Brofjorden

There is no drydock or tanker repair yard at Brofjorden or in Lysekil, so work here is done afloat, either alongside one of the refinery's jetties or at anchor. At the jetties the terminal's safety rules come first: equipment must be acceptable for the hazardous zones it enters, enclosed spaces are entered only on the ship's permit with a valid gas-free certificate, and the cargo operation sets the timetable. Cargo tanks stay closed during discharge or loading, so in-port scopes concentrate on segregated ballast tanks, void spaces, cofferdams, the forepeak, deck plating and longitudinals, and pipe supports on deck.

Anchorage work is reached by launch booked through the agent, and the exposed outer anchorage used by the largest crude carriers is only workable in moderate seas. For a full renewal or CAP programme, including cargo tanks, the readings taken here feed the yard where the tanker will dock. The largest crude carriers usually dock at big-ship yards far from Scandinavia, while product tankers trading in northern Europe commonly dock in Baltic, Polish or other European yards, and our team can travel there to complete the work.

  • Crude oil jetty near the fjord mouth — deck, void-space and segregated ballast tank gauging on crude carriers during discharge, within terminal and master approval.
  • Product jetties on the south shore of Trommekilen — ballast tank, forepeak and deck readings on product tankers while they load refinery cargo.
  • Anchorage positions east of Bohus-Malmön and around Lindholmen — launch-borne deck, air-pipe and accessible tank work on tankers waiting for a berth.
  • Deep-water anchorage south-west of the approach — waiting area for the largest crude carriers, workable for short condition checks in moderate weather.
  • Lysekil's town harbour — smaller craft lying in the Gullmarn gauged alongside when a job is arranged.
  • The tanker's docking yard — Brofjorden readings carried forward on the TM plan, or the team mobilised to the yard to finish cargo-tank gauging.

Thickness measurement through the survey cycle at Lysekil

Class rules set the survey cycle, and the cycle sets how much gauging a ship needs. A superintendent planning a call at Lysekil usually knows which survey is due; the table shows what the thickness measurement for each one typically involves. The exact extent comes from the class rules for the ship type and the surveyor attending, so the thickness measurement programme is agreed with the class before work starts.

SurveyWhen it fallsWhat the thickness measurement usually covers
Annual surveyEvery year, within three months of the anniversary dateGeneral examination. Gauging where the surveyor finds suspect areas or where substantial corrosion was recorded at an earlier survey.
Intermediate surveyIn place of the second or third annual surveySuspect areas, and on older ships and ESP ships selected ballast and cargo spaces with close-up survey; the extent grows with age.
Renewal survey No. 1Around 5 yearsThe first full baseline: suspect areas and selected plating and stiffeners, usually with modest steel renewal.
Renewal survey No. 2Around 10 yearsWider gauging of deck, bottom and side plating, transverse sections across the cargo area on ESP ships, and more close-up survey.
Renewal survey No. 3Around 15 yearsExtensive gauging of cargo and ballast tank structure and more transverse sections. The survey most likely to turn up steel renewal.
Renewal survey No. 4 and laterAround 20 and 25 yearsGauging extended to most structural members in cargo and ballast spaces. Charterers often add a Condition Assessment Programme.
Docking surveyTwice in each five-year periodBottom and side shell, sea chests, rudder and stern area while the hull is dry; suspect bottom plating gauged.

Port state control, vetting and tanker rules at Brofjorden

Port state control in Sweden is carried out by the Swedish Transport Agency under the Paris MoU, and oil and chemical tankers more than twelve years old fall into the Paris MoU's expanded inspection category, so the older crude carriers calling at Brofjorden can expect a thorough look at structure, ballast tanks and safety systems. Commercial scrutiny is often tougher still: oil majors and refiners screen tankers through OCIMF's SIRE 2.0 inspections and their own acceptance criteria, and a vetting observation on ballast tank coating or deck corrosion can keep a ship off charter. Ships calling at EU ports also carry an Inventory of Hazardous Materials under the EU Ship Recycling Regulation, and voyages to and from Brofjorden count towards EU ETS and FuelEU Maritime obligations.

For tankers the Enhanced Survey Programme sets the gauging pattern, with transverse sections across the cargo area and close-up survey that grows at each renewal survey, and many charterers now ask older tankers for a CAP rating as well. The corrosion that matters most on a crude carrier is often in places only reachable gas-free: bottom pitting under crude sludge, wastage under heating coils, and grooving at the bottom of longitudinals in cargo tanks. Ballast tanks, where coating breakdown starts at edges, welds and the upper parts of side tanks, are the in-port opportunity, which is why so many Brofjorden calls are used to measure them ahead of a docking.

Ships trading to Lysekil are inside a sulphur emission control area, where fuel must not exceed 0.10% sulphur unless an exhaust gas cleaning system (scrubber) is fitted. Scrubber wash-water piping, the overboard discharge and the hull penetration around it are among the fastest-corroding parts of a modern ship, so they belong in the gauging scope at every docking and, on open-loop systems, between dockings.

Tanker gauging jobs we see at Lysekil

Work at Brofjorden is shaped by the refinery's cargo programme. Scopes are defined tightly in advance, agreed with the terminal through the agent, and ordered so the most important spaces are measured first in case discharge finishes early or the ship is shifted to anchor. Readings are reported to the superintendent before the tanker sails, because the next decision, whether that is a yard booking, a charter or a sale, usually cannot wait for the next call. Most requests come from superintendents preparing a docking or answering a charterer, and a few from buyers who need an independent view of a tanker that is trading and cannot be taken off hire for an inspection. Examples of jobs that fit a Brofjorden call:

  • Ballast tank and deck gauging on a Suezmax discharging crude, to firm up the steel estimate before her third renewal survey in a yard abroad.
  • A product tanker on regular liftings, with two or three ballast tanks gauged per call until the whole set is complete before the docking.
  • Deck plating, longitudinals and pipe-support structure measured on an older Aframax after a vetting observation on deck corrosion.
  • Pre-purchase gauging of a product tanker at anchor while she waits for a berth, scoped by the buyer's technical adviser.
  • Forepeak, cofferdam and void-space readings on a VLCC at the crude jetty, with cargo tanks left for the CAP survey at her next docking.

How a thickness measurement job runs at Lysekil

The sequence for a thickness measurement job at Lysekil is short and written down, so the yard, the surveyor and the superintendent know who arranges what.

Göteborg Landvetter Airport is the nearest international gateway, and from there the team continues by road up the Bohuslän coast to Lysekil and Brofjorden. The refinery harbour is an ISPS facility with its own safety induction, so the agent registers the technicians' names and passport details with the terminal in advance and books launches for anchorage work. Sweden is a Schengen state, so the team travels from India on Schengen visas, and because tanker berthing dates move with the refinery's crude programme, we plan the visa period with room for the call to slip.

  • Send the vessel name or IMO number, ship type, class society, the survey due (annual, intermediate, renewal survey number, CAP or owner's condition survey), the port and dates, and the scope you expect.
  • We confirm the scope against the class rules for that survey, prepare the thickness measurement plan with frame and section references, and say whether the measurement will be credited to a class survey.
  • Mobilisation is planned around visa lead times and the vessel's schedule; the ship's agent arranges port access, and the yard or ship arranges staging, lighting, ventilation and gas-free certificates.
  • Gauging with calibrated ultrasonic thickness gauges: through sound coatings only where the gauge's through-coating mode has been verified on a coated reference, otherwise on cleaned bare steel, with every reading tied to its frame, strake and location on the sketch.
  • Readings are compared with original thicknesses as work proceeds; substantial and excessive corrosion and any cracks are reported to the attending surveyor and the superintendent the same day.
  • The final report is issued on the class thickness-measurement formats with sketches, a summary of locations exceeding the allowable margins, piping tables where piping was in scope, and the gauge calibration and technician certificates.

Who does the work, and when class approval applies

We send the team from India to the ship for each job rather than keeping staff at the port, and plan the mobilisation around visas and the vessel's itinerary. The work is planned and supervised by the founder, our Responsible NDT Level III (ASNT NDT Level III in UT, RT, MT, PT and VT, with more than eleven years of international field experience). Technicians hold certification under the company's written practice to ASNT SNT-TC-1A; Atlantis is ISO 9001 and ISO 14001 certified.

Thickness measurement that a classification society credits to a class survey has to be carried out by a firm approved by that society under IACS UR Z17. Atlantis is in the process of obtaining UR Z17 approval from DNV, Lloyd's Register and ABS. Until a certificate is issued, the readings we take are for the owner's own decisions, not for credit to a class survey, so tell us the vessel's class and the survey due when you enquire and we set the scope for the right purpose. Owner's and charterer's condition gauging, pre-docking steel estimates, pre-purchase and on-hire or off-hire gauging, and scrubber and piping condition checks between surveys do not need class approval.

Governing codes and standards

  • IACS UR Z7 hull classification surveys
  • IACS UR Z10.1 to Z10.5 (oil tankers, bulk carriers, chemical tankers, double-hull and double-skin ships)
  • IACS UR Z17 approval of service suppliers
  • SOLAS chapter XI-1 regulation 2 and the 2011 ESP Code
  • MARPOL Annex VI regulation 14 and the 2021 EGCS Guidelines (MEPC.340(77))
  • The rules of the vessel's classification society

What you receive

  • Thickness measurement report on the class formats, with sketches
  • Summary of substantial and excessive corrosion against allowable margins
  • Pitting and grooving records with depth and extent
  • Piping wall-thickness tables with isometric sketches
  • Magnetic particle or penetrant crack-detection reports
  • Gauge calibration records and technician certificates

Industries served

  • VLCC crude carriers
  • Suezmax tankers
  • Aframax tankers
  • Product tankers (LR and MR)
  • Coastal product and bunker tankers
  • Escort and harbour tugs
  • Small craft and workboats

Frequently asked questions

Can cargo tanks be gauged while a tanker is alongside at Brofjorden?

Not during cargo operations. Entering a cargo tank needs it to be cleaned, ventilated and certified gas-free, which does not happen while crude is being discharged or products loaded. What can be done alongside is ballast tank, void space, cofferdam, forepeak and deck gauging, provided the master and the terminal agree. Cargo-tank readings for a renewal survey or CAP belong at the docking yard.

Is gauging at the Lysekil anchorages realistic?

Yes, when the sea state allows a safe launch transfer. The anchorage positions closer to the coast are more sheltered than the deep-water area used by the largest crude carriers. A tanker waiting a day or two can have deck plating, air pipes and prepared ballast tanks measured, and we arrange the scope so that the priority readings are taken first in case the ship is called to the jetty.

Where do tankers from Brofjorden go for dry-docking?

There is no tanker drydock in Lysekil. VLCCs and Suezmaxes usually dock at large yards outside Scandinavia, while product tankers in northern European trade often use Baltic or Polish yards. Readings taken at Brofjorden are recorded against the TM plan's frames and sections, so the yard and the class surveyor can plan steel and close-up survey from them, and our team can follow the tanker to complete the programme.

How does winter weather on the Skagerrak affect a job?

Gales are the main risk. In strong winds from the westerly sectors, tanker movements and escort-tug operations at Brofjorden are suspended, so a ship can spend extra time at anchor or alongside. Short daylight in midwinter limits deck work, though work inside ballast tanks is not affected. We keep the team's dates flexible and stay in contact with the agent on the berthing schedule.

Does thickness measurement at Lysekil need class approval?

Thickness measurement that a classification society credits to a class survey has to be carried out by a firm approved by that society under IACS UR Z17. Atlantis is in the process of obtaining UR Z17 approval from DNV, Lloyd's Register and ABS. Until a certificate is issued, the readings we take are for the owner's own decisions, not for credit to a class survey, so tell us the vessel's class and the survey due when you enquire and we set the scope for the right purpose. Owner's and charterer's condition gauging, pre-docking steel estimates, pre-purchase and on-hire or off-hire gauging, and scrubber and piping condition checks between surveys do not need class approval.

Planning a survey or a drydock?

Send the vessel name or IMO number, the class, the survey due and the port. We reply with the scope, the mobilisation plan and a quote for that vessel.

Request a Quote

Request a ship gauging quote

Send the vessel name or IMO number, the class society, the survey due and the port. We reply with the scope, the mobilisation plan and a quote for that vessel.








Speak to an ASNT NDT Level III

Atlantis NDT provides ASNT Level III consulting, NDT training to ASNT SNT-TC-1A, inspection management software and independent report validation. Request a free consultation and we will return a tailored quote — affordable, accessible and fully customizable to your programme.