Eddy Current Testing Services in Portland

Professional Eddy Current Testing (ET) inspection services in Portland. ASNT Level II & III certified inspectors specializing in heat exchanger tube inspection, surface crack detection and conductivity testing for oil & gas, aerospace, power generation, and manufacturing industries.

Why Choose Atlantis NDT for ET in Portland?

Atlantis NDT provides certified Eddy Current Testing inspectors in Portland with expertise in API 510/570/653 compliance, ASME Section V procedures, and AWS D1.1 weld inspection. Contact us for a free quote.

Work in Portland is delivered under the same procedures and Level III oversight described on our national eddy current testing page, which covers bobbin, array and rotating-probe tube inspection plus surface examination on non-ferrous and coated components.

What Eddy Current Testing (ET) actually detects

Eddy current testing induces circulating currents in a conductive component and detects the impedance change caused by discontinuities. It is fast, requires no couplant, and works through thin coatings, which makes it the method of choice for tubing and surface crack detection on conductive materials.

  • Surface and near-surface cracking on conductive materials
  • Heat exchanger and condenser tube wall loss, pitting and cracking
  • Corrosion under thin coatings without removal
  • Conductivity and heat-treat verification on aluminium alloys
  • Weld toe cracking on painted structures

Codes and acceptance criteria applied

Examinations are performed to written procedures qualified against ASME Section V Article 8, ASTM E243, ASTM E571, ISO 15548 and EN 1711. Acceptance criteria are taken from the construction or in-service code governing the item — ASME Section VIII for pressure vessels, ASME B31.3 for process piping, API 510, API 570 and API 653 for in-service equipment, and AWS D1.1 for structural steel.

How the examination is controlled in Testing Portland

Agree personnel qualification, equipment checks, procedure revision and review responsibilities for the examination. Retain those records with the results and coverage limitations.

Reporting and follow-up

Results are issued in the client's required format with indications located against the component and, where relevant, against a corrosion monitoring location so thickness trends stay continuous between campaigns. Findings can be delivered into the client's own maintenance system, or onto a 3D asset model where remaining life and risk-based inspection ranking update as new data arrives.

Related: Eddy Current Testing (ET) overview · inspection management software · ASNT Level III consulting · NDT training and certification · request a quote for Testing Portland.

Eddy current inspection services for Portland: docked ships, fuel terminals and tube bundles

In Portland, eddy current work centers on two places. One is ship repair on Swan Island, where docked vessels open up coolers, condensers and coated steel for inspection. The other is the fuel terminals and pipelines that supply Oregon. Atlantis, based in Houston, sends ET crews with probes chosen for each tube material and coating system, and quotes every scope from the asset list.

Swan Island dry-docking periods. Vigor's original shipyard is on Swan Island. Its three dry docks include The Vigorous, a 960-foot floating dock that Vigor described as the largest in North America when it arrived in 2014. A docking period is often the only time a vessel's seawater-cooled heat exchangers, condensers and lube oil coolers can be opened. Bobbin-probe eddy current screens copper-nickel and brass tubing for pitting, erosion and wall loss. Rotating or array probes then size the tubes that will be plugged. Ferromagnetic tubing goes to IRIS. On the hull and deck, weld-probe eddy current and ACFM check weld toes and brackets for cracking through the paint. That saves blasting and recoating areas that turn out to be sound.

Terminals and pipelines. Oregon receives most of its refined products from Washington refineries, through the Olympic Pipeline and by barge on the Columbia. Portland terminals then send product onward, including on Kinder Morgan's roughly 115-mile line to Eugene, which carries about 42,000 barrels a day. In those terminals, eddy current methods help in two places. Pulsed eddy current screens insulated piping and vessels for wall loss without stripping insulation, and the readings show where to open it for a closer look. Surface ET and ACFM check dock and loading-structure welds for fatigue cracks. Tank floors and shells are a separate scope and are covered on tank inspection in Portland.

Which state applies. Vigor also operates a smaller facility in Vancouver, Washington, and crews regularly work on both banks of the river. Pressure equipment on the Washington side is under the Department of Labor & Industries rules in chapter 296-104 WAC, and Oregon jobs follow Oregon's own requirements. The governing jurisdiction, code and acceptance criteria are named in the quotation, not left for the report.

  • Shipboard coolers and condensers: bobbin screening, rotating or array sizing
  • Ferrous tubes: IRIS instead of conventional eddy current
  • Coated hull and deck welds: crack detection without stripping paint
  • Insulated terminal piping and vessels: pulsed eddy current wall-loss screening

Routing. Searches for ECT inspection services in general are answered by the national eddy current testing page. Vessel work in the city is on marine NDT in Portland. Technician courses are on ET technician training, and probe handling can be rehearsed in the Practical NDT eddy current module. Send tube counts, materials and docking dates through the Portland ET enquiry.

Need eddy current testing (ET) done, or learned?

Atlantis provides eddy current testing (ET) as an inspection service, trains technicians in it, and lets teams practise it on the Practical NDT simulator.