NDT Level III consulting

NDT regulatory compliance

Regulators rarely write NDT rules of their own. They adopt codes and expect the employer to show that inspection was done by qualified people to recognised practice. Atlantis maps an NDT programme against the regime it operates under and closes the gaps an inspector, a regulator or an auditor would find.

Regimes we map NDT programmes against

RegimeWhere it appliesWhat it asks of NDT
OSHA 29 CFR 1910.119(j) process safety managementUS facilities handling highly hazardous chemicals above threshold quantitiesInspection and testing to recognised and generally accepted good engineering practice (commonly API 510, 570 and 653), documented, with deficiencies corrected
PHMSA 49 CFR Parts 192 and 195US gas and hazardous liquid pipelinesNondestructive testing of welds by personnel trained and qualified in the procedures and equipment used (192.243, 195.234), with API 1104 incorporated by reference
ASME Boiler and Pressure Vessel Code and NBICPressure equipment under state or provincial jurisdictionPersonnel qualified as the referencing code section requires, commonly to SNT-TC-1A or CP-189, with Authorized Inspector acceptance
FAA 14 CFR Part 145US repair stations holding NDT ratingsNDT personnel qualified to the standard the repair station manual adopts, commonly NAS 410
NRC 10 CFR 50 Appendix B and ASME Section XINuclear plants and their suppliersA quality assurance programme, and CP-189 certification for Section XI NDE personnel
BSEE 30 CFR Part 250US offshore platformsInspection programmes and records the regulator can review
Classification society rules (IACS members)Ships and offshore unitsService supplier approval and NDT personnel requirements in the class rules

What compliance work includes

  • A map of the regime and the codes it adopts for each asset type and scope you work on.
  • A written practice and procedures aligned with what that regime adopts.
  • Records structured the way the regulator, the Authorized Inspector or the client will review them.
  • A gap list with a corrective plan and owners.
  • Ongoing Level III support as codes and editions change.

What we are and are not

Atlantis is not a regulator, an Authorized Inspection Agency or a notified body. We prepare the programme and the evidence; the regulator, the Authorized Inspector or the client decides acceptance.

Who does the work

Consulting is led by ASNT NDT Level III personnel. Our founder holds ASNT NDT Level III in UT, RT, MT, PT and VT, with more than eleven years of international NDT field experience. Aerospace work that needs a NAS 410 Level 3 is led through our associate who holds NAS 410 Level 3.

A Level III signs only within the methods they are certified in. Where a scope needs another method or scheme, the proposal names who will cover it before work starts. Under SNT-TC-1A the certifying authority always remains the employer; an outside Level III writes and approves the technical documents, prepares and grades examinations and signs in the capacity the written practice assigns.

Governing codes and standards

  • OSHA 29 CFR 1910.119
  • 49 CFR Parts 192 and 195
  • ASME BPVC Sections V, VIII and XI
  • NBIC
  • 14 CFR Part 145
  • 10 CFR 50 Appendix B
  • 30 CFR Part 250

What you receive

  • Regime and code map
  • Gap assessment
  • Aligned written practice and procedures
  • Corrective action plan

Industries served

  • Refining and chemicals
  • Pipelines
  • Power generation
  • Nuclear supply chain
  • Aviation repair stations
  • Offshore and marine

Frequently asked questions

Is SNT-TC-1A a regulation?

No. SNT-TC-1A is ASNT’s recommended practice for an employer’s own certification programme. It becomes mandatory when a code, a regulation or a contract adopts it, which is common for pressure equipment and pipelines in the US.

What does OSHA PSM require for NDT?

Paragraph (j) of the PSM standard requires inspection and testing that follows recognised and generally accepted good engineering practice, at a suitable frequency, documented with the date, the inspector, the equipment and the results, and correction of deficiencies. Most facilities meet it through API 510, 570 and 653 programmes.

Talk to an ASNT Level III

Tell us what the audit, the client or the code is asking for, and by when. We reply within one business day.

Request a consultation

Request a Level III consultation

Tell us what the audit, the client or the code is asking for, the methods and sites involved, and your dates. We reply within one business day.

Send your enquiry

Speak to an ASNT NDT Level III

Atlantis NDT provides ASNT Level III consulting, NDT training to ASNT SNT-TC-1A, inspection management software and independent report validation. Request a free consultation and we will return a tailored quote — affordable, accessible and fully customizable to your programme.