Careers · Houston, Texas, or anywhere in the USA (field)

Freelance UT Technician, Level II: Houston, Texas, or Anywhere in the USA

Atlantis NDT is building a network of freelance UT Level II technicians in Houston and across the USA, paid pro rata for the days they work on each assignment.

Posted 20 November 2026 · Freelance, pro rata per assignment

Role snapshot

TitleFreelance Ultrasonic Testing (UT) Technician, Level II
CompanyAtlantis Engineering Consultants LLC (Atlantis NDT)
LocationHouston, Texas, or anywhere in the USA; work is at client sites
EngagementFreelance, pro rata: paid for the days you work on each assignment, as an independent contractor
PayA day or hourly rate agreed for each assignment before you accept it
CommitmentNo minimum: you accept or decline each assignment offered
CertificationUT Level II to ASNT SNT-TC-1A, with the training and experience records behind it
Technical leadOur Responsible NDT Level III

About the role

Atlantis NDT carries out conventional NDT in the USA: ultrasonic, magnetic particle and penetrant testing for owners, operators, fabricators and inspection companies. Our work comes in uneven sizes, from one day of thickness readings on a piping circuit to several weeks on a refinery turnaround, so we work with freelance UT technicians who can join an assignment when it suits them.

You are paid pro rata, for the days you actually work on each assignment, at a rate agreed before you accept it. Houston and the Gulf Coast are where most of the work is, but we take assignments across the USA, so technicians based in other states are welcome to apply; tell us where you are and how far you will travel.

Typical assignments

  • Ultrasonic thickness measurement at the condition monitoring locations of process piping circuits, inspected under API 570 and API 574.
  • Thickness surveys of pressure vessel shells and heads for API 510 inspections, and of storage tank shells and roofs for API 653.
  • Shear-wave (angle beam) examination of welds to ASME Section V Article 4, ASME B31.3, ASME Section VIII and AWS D1.1, on new fabrication and repairs.
  • Straight-beam lamination checks on plate and pipe before welding or before a nozzle is set in.
  • Boiler tube thickness surveys during power plant and industrial boiler outages.
  • Wall-thickness readings on exposed pipe at excavations for pipeline operators.

What you will do

  • Carry out UT to the Atlantis written procedure for the job and the client's code or specification.
  • Calibrate and verify your instrument on the right reference blocks before, during and after the work, and record it.
  • Record every reading against its location, sketch or drawing reference, so the client can find the same point next time.
  • Report rejectable indications and readings below the minimum the client gives you to our Level III on the same day.
  • Complete the inspection report in our reporting system, with readings, sketches, calibration and equipment details.
  • Follow the client's site safety rules, permits and orientation requirements at all times.
  • Keep your certification, vision examination and site safety cards current, and send us renewals as they happen.

Requirements: must have

  • UT Level II certification to ASNT SNT-TC-1A from a current or previous employer, with the training and experience records that support it.
  • A near-vision examination (Jaeger J-2 at no less than 12 in.) within the last 12 months, and a colour contrast examination.
  • Field experience with ultrasonic thickness gauges and flaw detectors on carbon and stainless steel.
  • Able to read isometric drawings, weld maps and the acceptance criteria of the codes listed above.
  • Clear, accurate reports in written English.
  • Legally authorized to work in the United States.
  • A valid driver's license and willingness to travel to client sites.

Good to have

  • MT and PT Level II certification, so you can cover a combined UT, MT and PT scope on one visit.
  • A TWIC card, and site safety orientations such as Basic Orientation Plus and H2S awareness.
  • Refinery or chemical plant turnaround experience.
  • Experience with piping and vessel inspection data: condition monitoring locations, corrosion rates and minimum thicknesses.
  • Your own calibrated thickness gauge or flaw detector; we tell you for each assignment whether to bring yours or use ours.

How it works

Under ASNT SNT-TC-1A the employer, not a training course, certifies its technicians. So before your first assignment our Level III reviews your certification, training and experience records, gives you the examinations the Atlantis written practice calls for, and then certifies you to UT Level II under our written practice, or tells you plainly what is missing.

  1. Apply by email with your CV, certification copies and current vision examination.
  2. Our Level III reviews your records and holds a short technical call with you.
  3. You take the examinations our written practice requires and are certified under it.
  4. When an assignment comes up near you, we send the scope, site, dates and rate; you accept or decline.
  5. You complete the work and the report; our Level III reviews it before it goes to the client.
  6. You invoice for the days worked on the assignment, at the agreed rate.

Working as an independent contractor

Freelance technicians work with Atlantis as independent contractors (Form W-9 and 1099), so you are responsible for your own taxes. Some client sites ask contractors to carry their own insurance; when an assignment needs it, we tell you before you accept.

How to apply

Email your CV, copies of your UT certification and your most recent vision examination to info@atlantisndt.com with the subject line "Application – Freelance UT Technician, USA". Tell us the city you are based in and the states you are willing to travel to.

Our Level III reviews every application. If your records fit, we arrange a short technical call and then the certification steps above.

For questions, call +1 (281) 840-8969.

No fees, ever. We never ask candidates for a fee or a payment at any stage of hiring. If anyone asks you to pay to apply for, or to be placed in, a role at Atlantis NDT, it is not us; please tell us at info@atlantisndt.com.

We consider every applicant on their skills, experience and the requirements of the role, without regard to race, colour, religion, sex, national origin, age, disability or any other characteristic protected by law. Questions? Contact Atlantis NDT.

Other open positions: Business Development / Sales & Marketing Executive (Hyderabad).