{"id":"406","title":"TOFD Level 2 Practice Questions 2026: Free 30-Question Test","slug":"tofd-level-2-practice-questions-2026-free-mock-exam","date":"June 24, 2026","author":"Anoop Rayavarapu","category":"Practice Questions","metaDescription":"30 original TOFD Level II practice questions with answers: diffraction, PCS set-up, calibration, B-scan reading, depth and height sizing, dead zones.","snippet":"30 original TOFD Level II practice questions with answers: diffraction, PCS set-up, calibration, B-scan reading, depth and height sizing, dead zones.","content":"\n<p class=\"ptq-meta\" style=\"color:#475569;margin:0 0 16px;\">30 original questions in 6 topics, each with the correct answer, an explanation and its basis. Last reviewed October 16, 2026.</p>\n<section data-practice-test=\"2026-10\" aria-label=\"About this practice test\"><h2>About this TOFD Level II practice test</h2><p>These 30 multiple-choice questions are original study questions written by Atlantis NDT for ultrasonic technicians working toward Level II in time-of-flight diffraction. They are not ASNT exam questions. They follow the Level II job: choose probes and set the probe center separation, calibrate on the lateral wave and back wall, acquire encoded data, interpret the B-scan, size flaws from arrival times and report against a procedure.</p><p>Under ASNT SNT-TC-1A (2024 edition), the employer certifies Level II technicians after general, specific and practical examinations defined in its written practice, which sets the TOFD training and experience it requires. ASNT&apos;s central ASNT NDT Level II examinations include UT but do not list TOFD as a separate technique, so the TOFD examinations come from the employer&apos;s written practice. A good grounding in conventional UT is assumed.</p><p>Atlantis NDT runs NDT training year-round, with theory online and hands-on practice on its Practical NDT simulator or in person at the client&apos;s own facility. Simulator practice supports training; it does not replace the practical examination or the experience hours the employer&apos;s written practice requires.</p></section>\n<section aria-label=\"How to use this practice test\"><h2>How to use this practice test</h2><ul><li>Answer each question before opening the explanation.</li><li>For the sizing questions, draw the two probes, the tip and the two half-paths; the depth falls out of a right-angled triangle.</li><li>Keep units consistent: velocity in mm/&#xB5;s (5.9 for steel longitudinal) makes the arithmetic quick.</li><li>Note the topics where you miss questions, study them against your employer&apos;s TOFD procedure, then re-test.</li></ul><p style=\"margin:8px 0 0;\">Topics in this set:</p><ul><li><a href=\"#topic-principles-of-diffraction\">Principles of diffraction</a> (5 questions)</li><li><a href=\"#topic-probes-and-pcs-set-up\">Probes and PCS set-up</a> (5 questions)</li><li><a href=\"#topic-calibration-and-data-acquisition\">Calibration and data acquisition</a> (5 questions)</li><li><a href=\"#topic-interpretation-of-tofd-images\">Interpretation of TOFD images</a> (6 questions)</li><li><a href=\"#topic-sizing-and-calculations\">Sizing and calculations</a> (4 questions)</li><li><a href=\"#topic-limitations-codes-and-documentation\">Limitations, codes and documentation</a> (5 questions)</li></ul></section>\n<section class=\"ptq-note\" aria-label=\"Practice questions, not exam questions\" style=\"border-left:4px solid #d97706;padding:8px 0 8px 16px;margin:24px 0;\"><h2>Practice questions, not exam questions</h2><p>Atlantis NDT wrote these questions as original study material. They are not taken from ASNT or from any employer&apos;s examination, and real examinations differ in wording, emphasis and format.</p><p>Certification is a separate step: under ASNT SNT-TC-1A the employer certifies its technicians after the examinations its written practice sets, and ASNT runs central Level II examinations for several methods. A good score here is a study signal, not a qualification.</p></section>\n<aside data-course-next-step=\"2026-10\" data-placement=\"answer\" aria-label=\"Next step\" style=\"border-left:4px solid #2563eb;padding:10px 0 10px 16px;margin:24px 0;\"><p style=\"margin:0\"><strong>Next step:</strong> Preparing for the TOFD exam? The <a href=\"/tofd-training-certification-course\" style=\"color:#2563eb;text-decoration:underline;\">TOFD training course</a> adds structured classroom and hands-on training. Employers: <a href=\"/consulting/ndt-consulting-level-iii\" style=\"color:#2563eb;text-decoration:underline;\">ASNT Level III consulting</a> handles procedures, the written practice and qualification exams.</p></aside>\n<section class=\"ptq-topic\" id=\"topic-principles-of-diffraction\" aria-label=\"Principles of diffraction\"><h2>Principles of diffraction</h2><div class=\"ptq-question\" id=\"tofd2-01\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 1.</span> Which signal from a flaw does TOFD mainly rely on for detection and sizing?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Specular reflection from the flaw face</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Diffracted signals from the flaw tips</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Loss of through-transmitted amplitude only</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Surface waves generated at the flaw</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. Diffracted signals from the flaw tips</p><p style=\"margin:6px 0;\">When sound strikes the tip of a crack-like flaw, diffracted energy spreads over a wide range of angles. TOFD records these weak tip signals and uses their arrival times, rather than echo amplitude, to locate and size the flaw.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD principle; ASTM E2373</p></details></div><div class=\"ptq-question\" id=\"tofd2-02\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 2.</span> Why is TOFD height sizing less dependent on flaw orientation than amplitude-based sizing?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Because TOFD uses shear waves, which are not affected by orientation</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Because the instrument automatically corrects amplitude for orientation</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Because diffraction is weakly directional and sizing uses arrival times</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Because TOFD can only detect flaws perpendicular to the surface</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. Because diffraction is weakly directional and sizing uses arrival times</p><p style=\"margin:6px 0;\">Diffraction from a tip is weak but not strongly directional, and the depth of each tip is calculated from its arrival time. The echo amplitude, which depends heavily on orientation, is not used for sizing.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD principle</p></details></div><div class=\"ptq-question\" id=\"tofd2-03\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 3.</span> In a TOFD A-scan with longitudinal-wave probes, which signal normally arrives first?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> The lateral wave, just below the surface between the probes</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> The back-wall echo, reflected from the far surface of the plate</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> The upper-tip signal from a flaw at mid-wall, if one is present</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The mode-converted shear back-wall signal</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. The lateral wave, just below the surface between the probes</p><p style=\"margin:6px 0;\">The lateral wave takes the shortest path, directly between the probes just beneath the surface, so it arrives first. Tip signals from flaws follow, then the back-wall echo, then the slower mode-converted signals.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD principle</p></details></div><div class=\"ptq-question\" id=\"tofd2-04\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 4.</span> How do the diffracted signals from the upper and lower tips of an embedded crack normally compare in phase?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> In phase with each other, since both come from the same flaw</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Opposite in phase, the upper tip matching the back wall</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Only the upper tip gives a signal; the lower tip is shadowed</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Their phase depends only on the probe frequency and the PCS</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. Opposite in phase, the upper tip matching the back wall</p><p style=\"margin:6px 0;\">The upper and lower tip signals are 180&#xB0; apart in phase. The lateral wave and back-wall echo are also opposite in phase, and the upper tip normally matches the back wall while the lower tip matches the lateral wave, which helps identify each tip.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD principle; ISO 10863</p></details></div><div class=\"ptq-question\" id=\"tofd2-05\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 5.</span> Which signals in a TOFD A-scan arrive after the longitudinal back-wall echo?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> The lateral wave, which travels the longest path</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Upper-tip signals from flaws lying just below the scanning surface</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> The initial transmitter pulse, delayed by the wedges</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Mode-converted shear-wave signals, such as the shear back wall</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. Mode-converted shear-wave signals, such as the shear back wall</p><p style=\"margin:6px 0;\">Mode conversion at flaws and at the back wall produces shear-wave components that travel more slowly than longitudinal waves, so they arrive after the longitudinal back wall. The region of interest therefore arrives before the mode-converted signals.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD principle</p></details></div></section><section class=\"ptq-topic\" id=\"topic-probes-and-pcs-set-up\" aria-label=\"Probes and PCS set-up\"><h2>Probes and PCS set-up</h2><div class=\"ptq-question\" id=\"tofd2-06\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 6.</span> What probe arrangement is normally used for TOFD weld examination?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> A single shear-wave probe in pulse-echo mode, scanned from both sides of the weld</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> A 0&#xB0; dual-element probe scanned along the weld cap</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> A longitudinal-wave transmitter and receiver facing each other across the weld</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Two surface-wave probes placed side by side on one side of the weld</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. A longitudinal-wave transmitter and receiver facing each other across the weld</p><p style=\"margin:6px 0;\">TOFD is a pitch-catch technique: one probe transmits, the other receives the lateral wave, tip diffractions and back wall. The pair straddles the weld so the beams cover the weld volume.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD practice; ASTM E2373</p></details></div><div class=\"ptq-question\" id=\"tofd2-07\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 7.</span> Why are longitudinal waves used rather than shear waves for TOFD?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> They arrive first, ahead of all slower mode-converted signals</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Shear waves cannot be diffracted by the tip of a crack</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Longitudinal waves do not spread, so the beam stays narrow</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Shear waves are absorbed completely in carbon steel welds</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. They arrive first, ahead of all slower mode-converted signals</p><p style=\"margin:6px 0;\">Longitudinal waves are the fastest mode, so the lateral wave, tip signals and back wall all arrive before any mode-converted signals and the time window is simple to interpret. Shear waves do diffract at crack tips and do travel through carbon steel welds, and longitudinal beams spread like any other; shear waves are simply slower.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD principle</p></details></div><div class=\"ptq-question\" id=\"tofd2-08\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 8.</span> Why are highly damped, broadband probes used for TOFD?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> To increase the refracted angle of the beam in the part</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> To give short pulses for good depth resolution and smaller dead zones</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> To make the lateral wave disappear from the display</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> To allow the probes to work without couplant on smooth, clean plate</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. To give short pulses for good depth resolution and smaller dead zones</p><p style=\"margin:6px 0;\">Short pulses allow closely spaced signals, such as two tips of a small flaw or a tip just below the lateral wave, to be separated in time. Long ringing pulses enlarge the dead zones and blur the tip signals.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD principle</p></details></div><div class=\"ptq-question\" id=\"tofd2-09\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 9.</span> For a 30 mm thick plate with 60&#xB0; probes, what probe center separation (PCS) places the beam intersection at two-thirds of the thickness?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> 34.6 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> 52.0 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> 103.9 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> 69.3 mm</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. 69.3 mm</p><p style=\"margin:6px 0;\">PCS = 2 &#xD7; (2/3 &#xD7; T) &#xD7; tan &#x3B8; = 2 &#xD7; 20 &#xD7; tan 60&#xB0; = 40 &#xD7; 1.732 &#x2248; 69.3 mm. Setting the intersection at the full thickness would give 103.9 mm, and 34.6 mm is only half the required separation.</p><p style=\"margin:6px 0;color:#475569;\">Basis: TOFD set-up geometry (common practice: intersection at about 2/3 T)</p></details></div><div class=\"ptq-question\" id=\"tofd2-10\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 10.</span> Why are thick welds often examined with more than one TOFD probe pair or scan, each set up for a different depth zone?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Because one pair cannot cover the whole thickness with enough resolution</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Because TOFD can only detect flaws exactly at the beam intersection point</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Because the encoder can only record a limited depth range</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Because the back-wall echo must be excluded from every scan</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. Because one pair cannot cover the whole thickness with enough resolution</p><p style=\"margin:6px 0;\">Beam spread, attenuation and resolution all vary with depth, so thick sections are divided into zones, each with its own probe angle, frequency and PCS. A single pair still covers more than just the intersection point, but not the full thickness well.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD practice; ISO 10863</p></details></div></section><section class=\"ptq-topic\" id=\"topic-calibration-and-data-acquisition\" aria-label=\"Calibration and data acquisition\"><h2>Calibration and data acquisition</h2><div class=\"ptq-question\" id=\"tofd2-11\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 11.</span> Why is TOFD gain commonly set so that low-level grain noise is just visible across the display?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> To make the back-wall echo saturate so it is easy to see</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Because diffracted tip signals are weak and need high sensitivity</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> To remove the lateral wave from the top of the display</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Because the grain noise is needed to calibrate the encoder distance</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. Because diffracted tip signals are weak and need high sensitivity</p><p style=\"margin:6px 0;\">Tip diffractions are much weaker than reflections from flaw faces. Setting gain so that material noise is just visible shows the system is sensitive enough to record weak tip signals; the procedure defines the exact sensitivity setting.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD practice</p></details></div><div class=\"ptq-question\" id=\"tofd2-12\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 12.</span> Where should the TOFD acquisition time window normally start and end?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Start at the back-wall echo and end at the shear back wall</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Start just after the lateral wave and end just before the back-wall echo</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Start before the lateral wave and end after the back-wall echo</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Start at the initial pulse and end at the lateral wave</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. Start before the lateral wave and end after the back-wall echo</p><p style=\"margin:6px 0;\">The window must contain every signal that can come from the examined volume, from the lateral wave (scanning surface) to the back wall. Including the mode-converted region helps confirm indications near the back wall. The procedure or standard sets the exact margins.</p><p style=\"margin:6px 0;color:#475569;\">Basis: ASTM E2373; ISO 10863</p></details></div><div class=\"ptq-question\" id=\"tofd2-13\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 13.</span> Why must the digitization (sampling) rate be several times higher than the probe&apos;s nominal frequency?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> To increase the penetration of the probe into the weld</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> To reduce the size of each data file</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> To capture the waveform shape and phase faithfully for sizing</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Because the encoder needs a high sampling rate to count distance</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. To capture the waveform shape and phase faithfully for sizing</p><p style=\"margin:6px 0;\">TOFD relies on accurate arrival times and on phase to identify tips. Under-sampling distorts the waveform and introduces timing errors. Higher sampling increases file size rather than reducing it.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD practice; ASTM E2373</p></details></div><div class=\"ptq-question\" id=\"tofd2-14\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 14.</span> Why is the TOFD set-up checked on a reference block containing reflectors such as notches or side-drilled holes at known depths before scanning?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> To confirm coverage, sensitivity and depth calibration</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> To measure the hardness of the weld and heat-affected zone</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> To determine the client&apos;s acceptance criteria for the weld</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> To set the scanner speed only</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. To confirm coverage, sensitivity and depth calibration</p><p style=\"margin:6px 0;\">Known reflectors at the top, middle and bottom of the zone show that the beams reach them, that their signals are visible at the chosen gain and that the calculated depths are right. Acceptance criteria come from the code or specification.</p><p style=\"margin:6px 0;color:#475569;\">Basis: ASTM E2373; ISO 10863</p></details></div><div class=\"ptq-question\" id=\"tofd2-15\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 15.</span> On the component, the lateral wave and back-wall arrival times are measured with a known plate thickness and PCS. What can these two signals be used to calibrate?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> The probe frequency and the pulse bandwidth</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> The weld acceptance level for the scan</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> The encoder resolution and scan increment</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The probe delay and the depth scale</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. The probe delay and the depth scale</p><p style=\"margin:6px 0;\">The lateral wave corresponds to zero depth and the back wall to the known thickness. With the PCS known, these two references fix the time zero (probe delay) and the velocity used to convert arrival times into depths.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD practice</p></details></div></section><section class=\"ptq-topic\" id=\"topic-interpretation-of-tofd-images\" aria-label=\"Interpretation of TOFD images\"><h2>Interpretation of TOFD images</h2><div class=\"ptq-question\" id=\"tofd2-16\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 16.</span> How does an embedded planar flaw typically appear in a TOFD B-scan (D-scan) image?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> As a break in the lateral wave, with no signal between it and the back wall</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> As a break in the back-wall echo, with no signal between it and the lateral wave</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> As a single short hyperbolic arc with no measurable depth extent</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> As two opposite-phase tip signals, with the lateral wave and back wall undisturbed</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. As two opposite-phase tip signals, with the lateral wave and back wall undisturbed</p><p style=\"margin:6px 0;\">An embedded flaw with measurable height has two tips, each producing its own diffraction signal, and it does not interrupt the lateral wave or the back wall. A single short arc is typical of a point reflector.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD interpretation; ISO 10863</p></details></div><div class=\"ptq-question\" id=\"tofd2-17\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 17.</span> How does a flaw breaking the scanning surface typically appear in TOFD?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> As a break in the lateral wave plus a lower-tip signal</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> As two separate tip signals below an undisturbed lateral wave</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> As a break in the back-wall echo, with the lateral wave intact</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> As a signal arriving after the mode-converted shear back wall</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. As a break in the lateral wave plus a lower-tip signal</p><p style=\"margin:6px 0;\">A flaw open to the scanning surface interrupts the lateral wave path; its only separate tip is the lower one. Its upper end is at the surface, inside the lateral wave.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD interpretation</p></details></div><div class=\"ptq-question\" id=\"tofd2-18\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 18.</span> How does a crack open to the back wall (inside surface) typically appear in TOFD?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> As a lower-tip signal only, with an undisturbed back wall</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> As an upper-tip signal plus a break in the back-wall echo</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> As an interruption of the lateral wave only</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> No signal appears, since TOFD cannot detect such flaws</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. As an upper-tip signal plus a break in the back-wall echo</p><p style=\"margin:6px 0;\">The crack&apos;s lower end is at the back wall, so instead of a lower-tip signal the back-wall echo is disturbed or shadowed beneath the flaw. The upper tip gives a diffraction signal above it.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD interpretation</p></details></div><div class=\"ptq-question\" id=\"tofd2-19\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 19.</span> How does a point reflector, such as an isolated pore, typically appear in a non-parallel TOFD scan?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> As a long flat line parallel to the lateral wave</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> As a break in the back-wall echo</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> As a short hyperbolic arc with little depth extent</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> As a disturbance of the lateral wave</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. As a short hyperbolic arc with little depth extent</p><p style=\"margin:6px 0;\">As the probes approach and pass a point reflector, the arrival time first decreases and then increases, producing a characteristic hyperbolic arc. It has no measurable height, unlike a planar flaw with separate upper and lower tips.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD interpretation</p></details></div><div class=\"ptq-question\" id=\"tofd2-20\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 20.</span> Why is the phase of TOFD signals useful during interpretation?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> It shows the probe frequency actually achieved</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> It indicates the flaw&apos;s chemical composition, such as slag or oxide</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> It replaces the need for an encoder on short scans</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> It shows whether a signal is an upper or a lower tip</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. It shows whether a signal is an upper or a lower tip</p><p style=\"margin:6px 0;\">Because upper and lower tips give opposite phases, the analyst can tell whether a single signal is an upper tip (suggesting a back-wall-breaking flaw) or a lower tip (suggesting a scanning-surface-breaking flaw), and can pair the tips of an embedded flaw.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD interpretation</p></details></div><div class=\"ptq-question\" id=\"tofd2-21\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 21.</span> Over a short section of the scan, the lateral wave and the back-wall echo both disappear. What is the most likely cause?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> A large embedded crack between the two probes</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Loss of coupling, so that section must be rescanned</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> A lamination at mid-thickness under both probes</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Normal behavior; these signals often fade on thick plate</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. Loss of coupling, so that section must be rescanned</p><p style=\"margin:6px 0;\">An embedded flaw does not remove the lateral wave, and a mid-wall lamination would block the back wall but not the lateral wave. Losing both together points to coupling, and the data in that section cannot be evaluated.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD practice (data quality)</p></details></div></section><section class=\"ptq-topic\" id=\"topic-sizing-and-calculations\" aria-label=\"Sizing and calculations\"><h2>Sizing and calculations</h2><div class=\"ptq-question\" id=\"tofd2-22\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 22.</span> A TOFD set-up uses a PCS of 80 mm on steel (longitudinal velocity 5,900 m/s). After removing the probe delay, a tip signal arrives at 16.95 &#xB5;s. What is the depth of the tip, assuming it lies midway between the probes?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> 25.0 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> 30.0 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> 40.0 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> 50.0 mm</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. 30.0 mm</p><p style=\"margin:6px 0;\">Total path = 5.9 mm/&#xB5;s &#xD7; 16.95 &#xB5;s &#x2248; 100 mm, so each half-path is 50 mm. With half the PCS S = 40 mm, depth d = &#x221A;(50&#xB2; &#x2212; 40&#xB2;) = &#x221A;900 = 30.0 mm. 50 mm is the half-path, not the depth.</p><p style=\"margin:6px 0;color:#475569;\">Basis: TOFD depth equation, d = &#x221A;((ct/2)&#xB2; &#x2212; S&#xB2;)</p></details></div><div class=\"ptq-question\" id=\"tofd2-23\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 23.</span> In the same set-up (PCS 80 mm, 5,900 m/s), the upper tip of a flaw is at 30.0 mm depth and the lower-tip signal arrives at 19.66 &#xB5;s. What is the flaw height?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> 2.7 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> 8.0 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> 16.0 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> 12.0 mm</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. 12.0 mm</p><p style=\"margin:6px 0;\">Total path = 5.9 &#xD7; 19.66 &#x2248; 116 mm, half-path 58 mm. Lower-tip depth = &#x221A;(58&#xB2; &#x2212; 40&#xB2;) = &#x221A;1,764 = 42.0 mm. Height = 42.0 &#x2212; 30.0 = 12.0 mm. Height is a difference in depth, not the difference in path or time.</p><p style=\"margin:6px 0;color:#475569;\">Basis: TOFD depth equation, d = &#x221A;((ct/2)&#xB2; &#x2212; S&#xB2;)</p></details></div><div class=\"ptq-question\" id=\"tofd2-24\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 24.</span> How is flaw length normally measured in a non-parallel TOFD scan?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> From the time difference between the upper and lower tip signals</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> From the peak amplitude of the A-scan at the flaw center</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> From the duration of the lateral wave signal in the A-scan</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Along the scan axis, with hyperbolic cursors fitted to the ends</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. Along the scan axis, with hyperbolic cursors fitted to the ends</p><p style=\"margin:6px 0;\">Length lies along the encoded scan axis. Because beam spread makes the ends trail off as arcs, hyperbolic cursors are fitted to the ends rather than reading where the signal visibly fades. The tip time difference gives height, not length.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD sizing practice; ISO 10863</p></details></div><div class=\"ptq-question\" id=\"tofd2-25\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 25.</span> In a non-parallel TOFD scan, the depth calculation assumes the flaw lies midway between the probes. What is the effect if the flaw is actually off-center?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> The depth is overestimated, because an off-center tip has a longer path</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> There is no effect, because TOFD depth is independent of lateral position</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> The flaw cannot be detected at all by the receiver</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The calculated height doubles but depth is unchanged</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. The depth is overestimated, because an off-center tip has a longer path</p><p style=\"margin:6px 0;\">For a given depth, the sound path is shortest at the midpoint between the probes. An off-center tip has a longer path, so the midpoint assumption gives a depth greater than the true depth. A parallel scan or offset scans can be used to locate the flaw laterally.</p><p style=\"margin:6px 0;color:#475569;\">Basis: TOFD geometry (lateral position uncertainty)</p></details></div></section><section class=\"ptq-topic\" id=\"topic-limitations-codes-and-documentation\" aria-label=\"Limitations, codes and documentation\"><h2>Limitations, codes and documentation</h2><div class=\"ptq-question\" id=\"tofd2-26\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 26.</span> Why are flaws very close to the scanning surface difficult to detect and size with TOFD?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Their signals arrive after the back wall and are outside the window</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Diffraction does not occur at tips close to the surface</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Their tip signals arrive within the lateral wave and are masked</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The encoder cannot record positions for near-surface signals</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. Their tip signals arrive within the lateral wave and are masked</p><p style=\"margin:6px 0;\">The lateral wave has a finite duration, and signals from tips just below the surface arrive within it. Higher frequency, shorter pulses or a smaller PCS shrink this dead zone, and supplementary techniques such as pulse-echo UT or PAUT are commonly used to cover it.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD principle (dead zones)</p></details></div><div class=\"ptq-question\" id=\"tofd2-27\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 27.</span> What limits TOFD detection of small flaws very close to the back wall?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Their tip signals are masked by the back-wall echo</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> The lateral wave interferes with them</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Mode-converted signals arrive before them and hide them</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Longitudinal waves cannot reach the back wall of thick plate</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. Their tip signals are masked by the back-wall echo</p><p style=\"margin:6px 0;\">A tip signal that arrives within the duration of the back-wall echo cannot be separated from it, which creates a back-wall dead zone. The mode-converted signals arrive after, not before, the longitudinal back wall.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD principle (dead zones)</p></details></div><div class=\"ptq-question\" id=\"tofd2-28\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 28.</span> Which pair of standards specifically addresses TOFD examination of welds?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> ASTM E2700 and ISO 13588</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> ASTM E2373 and ISO 10863</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> ASTM E309 and ASTM E426</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> ASTM E1444 and ISO 9934</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. ASTM E2373 and ISO 10863</p><p style=\"margin:6px 0;\">ASTM E2373 and ISO 10863 cover TOFD. ASTM E2700 and ISO 13588 cover phased array UT of welds, ASTM E309 and E426 cover eddy current examination of tubular products, and ASTM E1444 and the ISO 9934 series cover magnetic particle testing.</p><p style=\"margin:6px 0;color:#475569;\">Basis: ASTM E2373; ISO 10863</p></details></div><div class=\"ptq-question\" id=\"tofd2-29\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 29.</span> Which joint condition makes a standard TOFD scan difficult or impossible?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> A flat butt weld with clear access on both sides on the same surface</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> A weld with the cap ground flush to the plate surface</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> A nozzle or tee joint without access to both sides on one surface</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> A plate thicker than the probe&apos;s near-field length</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. A nozzle or tee joint without access to both sides on one surface</p><p style=\"margin:6px 0;\">Standard TOFD needs the transmitter and receiver on opposite sides of the weld on the same surface. Where geometry prevents that, other techniques or special configurations are needed. A flush cap actually helps scanning.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General TOFD practice (limitations)</p></details></div><div class=\"ptq-question\" id=\"tofd2-30\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 30.</span> Which information should a TOFD report contain so the examination can be reproduced?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> The list of rejected indications with their positions</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> The operator&apos;s name, the date and the client&apos;s order number</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Probes, PCS, time window, sensitivity, reference block, scan plan and data file</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The color palette and print settings used for the images</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. Probes, PCS, time window, sensitivity, reference block, scan plan and data file</p><p style=\"margin:6px 0;\">Another qualified technician must be able to rebuild the set-up and coverage from the report, and the data file must be traceable to it. Indications, the operator and the date are recorded too, but alone they do not allow the examination to be repeated.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General NDT reporting practice; ASTM E2373</p></details></div></section>\n<section data-course-next-step=\"2026-10\" data-placement=\"end\" aria-label=\"Course next step\" style=\"border-left:4px solid #2563eb;padding:10px 0 10px 16px;margin:24px 0;\"><h2 style=\"font-size:1.25rem;font-weight:700;line-height:1.3;margin:0 0 8px;\">Next step: TOFD training course</h2><p style=\"margin:0 0 8px;\">Practice questions check recall. Structured training adds the classroom and hands-on hours your certification route requires. The <a href=\"/tofd-training-certification-course\" style=\"color:#2563eb;text-decoration:underline;\">TOFD training course</a> covers probe-pair configuration and probe centre spacing, lateral-wave and back-wall identification, and D-scan depth sizing. Completing a course is not certification: under an employer-based scheme such as SNT-TC-1A, your employer certifies you after its own examinations.</p><p style=\"margin:0 0 8px;\"><strong>For employers:</strong> <a href=\"/consulting/ndt-consulting-level-iii\" style=\"color:#2563eb;text-decoration:underline;\">ASNT Level III consulting</a> covers procedures, the written practice, qualification examinations and audit support for your technicians.</p></section>\n<section data-practice-next=\"2026-10\" aria-label=\"Where to go next\" style=\"border-left:4px solid #2563eb;padding:10px 0 10px 16px;margin:24px 0;\"><h2>Where to go next</h2><p>Atlantis NDT courses run year-round, with theory online and hands-on practice on the Practical NDT simulator or in person at the client&apos;s own facility. From here:</p><ul><li><a href=\"/ultrasonic-testing-training\">Ultrasonic testing (UT) training</a>: what Level I and Level II mean in the method and what the practical examination tests. TOFD is an ultrasonic technique, so it sits inside the ultrasonic method body of knowledge.</li><li><a href=\"/tools/ultrasonic-a-scan-simulator\">Ultrasonic A-scan simulator</a>: rehearse range, gain and gate settings on a simulated flaw detector in the browser.</li><li><a href=\"/ndt-practice-tests\">All NDT practice tests</a>: Level II sets for UT, PAUT, TOFD, RT, MT, PT, VT and ET, with exam preparation guides.</li><li><a href=\"/asnt-ndt-level-ii-exam-prep\">ASNT NDT Level II exam preparation</a>: if you are sitting ASNT&apos;s central Level II examination.</li><li><a href=\"/asnt-level-iii-ut-exam-prep\">ASNT Level III UT exam preparation</a>: the route once Level II work and experience are behind you.</li></ul><p><a href=\"/contact?service=training&amp;subject=TOFD%20Level%20II%20training\">Enquire about TOFD Level II training</a> for yourself or for a team. Tell us the method, the level and where the trainees are based.</p></section>","order":0,"createdAt":"2026-06-24","updatedAt":"2026-10-16T00:00:00Z","h1":"Time-of-Flight Diffraction (TOFD) Level II Practice Questions"}