{"id":"482","title":"Sour Cracking 2026 — HIC, SOHIC, SSC per NACE MR0175 Decoded","slug":"sour-cracking-hic-sohic-2026-decoded","date":"June 24, 2026","author":"Anoop Rayavarapu","category":"Corrosion + Damage Mechanisms","metaDescription":"Sour Cracking 2026 — HIC, SOHIC, SSC per NACE MR0175 Decoded — sour cracking (HIC + SOHIC + SSC), NACE MR0175 / ISO 15156 compliance, hard-spot avoidance. Informational guide by an ASNT NDT Level III.","snippet":"Sour Cracking 2026 — HIC, SOHIC, SSC per NACE MR0175 Decoded — sour cracking (HIC + SOHIC + SSC), NACE MR0175 / ISO 15156 compliance, hard-spot avoidance. Informational guide by an ASNT NDT Level III.","content":"<!-- atlantis-inline-anchors-v1 -->\n<h2>Sour Cracking 2026 &#x2014; HIC, SOHIC, SSC per NACE MR0175 Decoded</h2>\n<p>sour cracking (HIC + SOHIC + SSC), NACE MR0175 / ISO 15156 compliance, hard-spot avoidance. Catalogued by API 571 as a major damage mechanism affecting fixed equipment in refining and petrochem. This guide walks through mechanism, susceptibility, detection, and prevention.</p>\n<h2>Mechanism</h2>\n<p>Wet H2S damage covers four forms in carbon and low-alloy steels exposed to aqueous H2S: hydrogen blistering, hydrogen-induced cracking (HIC), stress-oriented hydrogen-induced cracking (SOHIC) and sulfide stress cracking (SSC). Corrosion in wet H2S generates atomic hydrogen that diffuses into the steel; blistering and HIC form at inclusions and laminations, SOHIC forms in stacked arrays through-wall near welds where residual stress is high, and SSC occurs in hard welds and heat-affected zones. NACE MR0175/ISO 15156 (oil and gas production) and NACE MR0103/ISO 17945 (refining) are the materials requirements used to reduce susceptibility; they are not the damage mechanism itself. Reference: API RP 571 (3rd ed.) paragraph 3.67 (wet H2S damage).</p>\n<h2>Susceptibility Factors</h2>\n<ul>\n<li>Free water with dissolved H2S; damage increases with H2S partial pressure, low pH, and the presence of cyanides or bisulfide</li>\n<li>Steel cleanliness: inclusion content and plate quality (HIC-resistant steels reduce risk)</li>\n<li>Hardness of welds and HAZ (SSC)</li>\n<li>Residual stress near unstressed-relieved welds (SOHIC)</li>\n<li>Temperatures from ambient to roughly 150&#xB0;C</li>\n</ul>\n<h2>Detection Methods</h2>\n<ul>\n<li>Wet fluorescent magnetic particle testing (WFMT) of internal surfaces for surface-breaking cracks</li>\n<li>Angle-beam UT, PAUT and TOFD for subsurface HIC and SOHIC detection and sizing</li>\n<li>Advanced UT techniques (for example AUBT-type or straight-beam scanning) to map blistering and HIC</li>\n<li>Visual inspection for blisters</li>\n<li>Hardness testing of welds where SSC is a concern</li>\n</ul>\n<p>Technique selection should follow the damage mechanism, with procedures approved under the employer&apos;s written practice.</p>\n<h2>Prevention + Mitigation</h2>\n<ul>\n<li>HIC-resistant steels for new equipment in severe service</li>\n<li>Weld and HAZ hardness control and PWHT per materials standards (SSC, SOHIC)</li>\n<li>Process changes that lower H2S or cyanide levels or raise pH where feasible</li>\n<li>Alloy cladding or linings</li>\n<li>Inhibitor programmes in some services</li>\n</ul>\n<h2>How RBI and FFS Use the Inspection Data</h2>\n<p>Owners that run risk-based inspection (API RP 580/581) use damage-mechanism susceptibility and measured inspection results to set inspection priorities and intervals, and damage beyond code acceptance may be referred for an engineering fitness-for-service assessment (API 579-1/ASME FFS-1). Both are owner and engineering responsibilities; Atlantis NDT does not provide RBI or FFS services. The Atlantis Digital Twin platform can display the underlying inspection data on a 3D model.</p>\n<h2>FAQs</h2>\n<h3>Q1: Which inspection method finds this damage?</h3>\n<p><strong>A:</strong> Wet fluorescent magnetic particle testing (WFMT) of internal surfaces for surface-breaking cracks; angle-beam UT, PAUT and TOFD for subsurface HIC and SOHIC detection and sizing.</p>\n<h3>Q2: Where is it described in the codes?</h3>\n<p><strong>A:</strong> API RP 571 (3rd ed.) paragraph 3.67 (wet H2S damage). API RP 571 describes the mechanism, critical factors, affected equipment and inspection and monitoring options.</p>\n<h3>Q3: Who decides the inspection interval?</h3>\n<p><strong>A:</strong> The owner&apos;s authorized inspector under API 510, 570 or 653, or the owner&apos;s RBI assessment where one is used. Atlantis NDT does not provide RBI services.</p>\n<h3>Q4: How does Atlantis NDT help?</h3>\n<p><strong>A:</strong> With ASNT Level III consulting on NDE procedures and technique selection, ASNT SNT-TC-1A training for the technicians who perform the examinations, and inspection software (Atlantis ERP and the Digital Twin platform) that holds the inspection records.</p>\n<h2>Related Codes, Qualification and Records</h2>\n<p>Recommended practices and guides inform an inspection programme; binding requirements come from the in-service codes (API 510, API 570, API 653), the construction codes and the regulations that apply to the asset. NDE personnel are qualified under the employer&apos;s written practice (commonly ASNT SNT-TC-1A, ANSI/ASNT CP-189 or ISO 9712), and NDE procedures are approved by the employer&apos;s NDT Level III. Acceptance of indications follows the governing code; damage beyond its rules may be referred for an engineering fitness-for-service assessment (API 579-1/ASME FFS-1), which Atlantis NDT does not perform. Keep procedure revisions, calibration records and personnel certifications traceable; <a href=\"/erp\">Atlantis ERP</a> can hold these records.</p>\n<h2>Frequently Asked Questions</h2>\n<h3>Q1: Which code edition of Sour Cracking 2026 should we reference?</h3>\n<p>Use the edition required by the contract, governing requirements and applicable jurisdiction. Record that edition in the procedure and evaluate changes before adopting a later publication.</p>\n<h3>Q2: What is the typical implementation timeline?</h3>\n<p><strong>A:</strong> 4-20 weeks depending on team size + scope. SMB: 4 weeks. Mid-size: 8-12 weeks. Enterprise multi-region: 12-20 weeks. Atlantis NDT delivers phased rollout with clear milestone gates.</p>\n<h3>Q3: Does Atlantis NDT publish pricing?</h3>\n<p><strong>A:</strong> No &#x2014; pricing varies by region, scope, delivery model, and team size. Atlantis NDT is positioned as affordable, accessible, and fully customizable. Free 30-min consultation + tailored quote.</p>\n<h3>Q4: How does Atlantis integrate with our existing stack?</h3>\n<p><strong>A:</strong> Atlantis ERP has an open REST API, so it connects to SAP, Maximo, NetSuite or any other system that accepts API connections; each integration is scoped with you during implementation. Free integration scoping consultation.</p>\n<h3>Q5: How do I start?</h3>\n<p><strong>A:</strong> Request a free 30-min consultation at <a href=\"/contact\">/contact</a>. We reply within one business day. We scope your asset class + damage mechanisms + code requirements + delivery model preference + integration needs in a single call.</p>\n<h2>Related Atlantis NDT Resources</h2>\n<ul>\n  <li><a href=\"/asnt-certification\">ASNT certification</a> &#xB7; <a href=\"/api-510-certification\">API 510</a> &#xB7; <a href=\"/api-570-certification\">API 570</a> &#xB7; <a href=\"/api-653-certification\">API 653</a></li>\n  <li><a href=\"/consulting/ndt-consulting-level-iii\">ASNT Level III consulting</a> &#x2014; outsourced Level III with SLA</li>\n  <li><a href=\"/erp\">Atlantis NDT ERP</a> &#x2014; affordable, fully customizable, 28 business apps</li>\n  <li><a href=\"/digital-twins\">Atlantis Digital Twin platform</a> &#x2014; 3D inspection-data overlay, predictive maintenance</li>\n  <li><a href=\"/best-ndt-reporting-software-2026\">NDT reporting software</a> &#x2014; IACS Marine bundle out of the box</li>\n</ul>\n<p><strong>Atlantis NDT</strong> &#x2014; led by Anoop Rayavarapu (ASNT NDT Level III in UT, RT, MT, PT and VT). Free consultation. <a href=\"/contact\">request a free consultation</a>. Pricing varies by region and scope.</p>","order":0,"createdAt":"2026-06-24","updatedAt":"2026-10-18","quickAnswer":{"question":"What is Sour Cracking 2026 and how do I detect it?","answer":"Wet H2S damage covers four forms in carbon and low-alloy steels exposed to aqueous H2S: hydrogen blistering, hydrogen-induced cracking (HIC), stress-oriented hydrogen-induced cracking (SOHIC) and sulfide stress cracking (SSC). Corrosion in wet H2S generates atomic hydrogen that diffuses into the steel; blistering and HIC form at inclusions and laminations, SOHIC forms in stacked arrays through-wall near welds where residual stress is high, and SSC occurs in hard welds and heat-affected zones. Informational guide by an ASNT NDT Level III; RBI and FFS decisions stay with the owner.","bullets":["Free water with dissolved H2S; damage increases with H2S partial pressure, low pH, and the presence of cyanides or bisulfide","Detection: Wet fluorescent magnetic particle testing (WFMT) of internal surfaces for surface-breaking cracks","Mitigation: HIC-resistant steels for new equipment in severe service"]}}