{"id":"405","title":"PAUT Level 2 Practice Questions 2026: Free 30-Question Test","slug":"paut-level-2-practice-questions-2026-free-mock-exam","date":"June 24, 2026","author":"Anoop Rayavarapu","category":"Practice Questions","metaDescription":"30 original PAUT Level II practice questions with answers: focal laws, wedge delay, ACG and TCG, scan plans, encoded data analysis, sizing and limitations.","snippet":"30 original PAUT Level II practice questions with answers: focal laws, wedge delay, ACG and TCG, scan plans, encoded data analysis, sizing and limitations.","content":"\n<p class=\"ptq-meta\" style=\"color:#475569;margin:0 0 16px;\">30 original questions in 6 topics, each with the correct answer, an explanation and its basis. Last reviewed October 16, 2026.</p>\n<section data-practice-test=\"2026-10\" aria-label=\"About this practice test\"><h2>About this PAUT Level II practice test</h2><p>These 30 multiple-choice questions are original study questions written by Atlantis NDT for phased array technicians working toward Level II. They are not ASNT exam questions. They follow the Level II job: build and verify the set-up, calibrate wedge delay, ACG and TCG, run encoded scans to a scan plan, analyze the data, size indications and report against a procedure.</p><p>Under ASNT SNT-TC-1A (2024 edition), the employer certifies Level II technicians after general, specific and practical examinations defined in its written practice, which sets the PAUT training and experience it requires. ASNT&apos;s central ASNT NDT Level II examinations include UT but do not list PAUT as a separate technique, so the PAUT examinations come from the employer&apos;s written practice. A good grounding in conventional UT is assumed.</p><p>Atlantis NDT runs NDT training year-round, with theory online and hands-on practice on its Practical NDT simulator or in person at the client&apos;s own facility. Simulator practice supports training; it does not replace the practical examination or the experience hours the employer&apos;s written practice requires.</p></section>\n<section aria-label=\"How to use this practice test\"><h2>How to use this practice test</h2><ul><li>Answer each question before opening the explanation.</li><li>Sketch the beam geometry for the calculation questions; a quick drawing catches most sine and cosine mix-ups.</li><li>Mark the topics where you miss questions and review them against your employer&apos;s procedure and scan plans.</li><li>Re-test after study and check that your weak topics have improved.</li></ul><p style=\"margin:8px 0 0;\">Topics in this set:</p><ul><li><a href=\"#topic-phased-array-principles\">Phased array principles</a> (5 questions)</li><li><a href=\"#topic-set-up-and-calibration\">Set-up and calibration</a> (6 questions)</li><li><a href=\"#topic-scan-planning-and-coverage\">Scan planning and coverage</a> (5 questions)</li><li><a href=\"#topic-data-analysis-and-sizing\">Data analysis and sizing</a> (7 questions)</li><li><a href=\"#topic-codes-procedures-and-documentation\">Codes, procedures and documentation</a> (3 questions)</li><li><a href=\"#topic-method-limitations\">Method limitations</a> (4 questions)</li></ul></section>\n<section class=\"ptq-note\" aria-label=\"Practice questions, not exam questions\" style=\"border-left:4px solid #d97706;padding:8px 0 8px 16px;margin:24px 0;\"><h2>Practice questions, not exam questions</h2><p>Atlantis NDT wrote these questions as original study material. They are not taken from ASNT or from any employer&apos;s examination, and real examinations differ in wording, emphasis and format.</p><p>Certification is a separate step: under ASNT SNT-TC-1A the employer certifies its technicians after the examinations its written practice sets, and ASNT runs central Level II examinations for several methods. A good score here is a study signal, not a qualification.</p></section>\n<aside data-course-next-step=\"2026-10\" data-placement=\"answer\" aria-label=\"Next step\" style=\"border-left:4px solid #2563eb;padding:10px 0 10px 16px;margin:24px 0;\"><p style=\"margin:0\"><strong>Next step:</strong> Preparing for the PAUT Level 2 exam? The <a href=\"/paut-level-2-training-course\" style=\"color:#2563eb;text-decoration:underline;\">PAUT Level 2 course</a> adds structured classroom and hands-on training. Employers: <a href=\"/consulting/ndt-consulting-level-iii\" style=\"color:#2563eb;text-decoration:underline;\">ASNT Level III consulting</a> handles procedures, the written practice and qualification exams.</p></aside>\n<section class=\"ptq-topic\" id=\"topic-phased-array-principles\" aria-label=\"Phased array principles\"><h2>Phased array principles</h2><div class=\"ptq-question\" id=\"paut2-01\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 1.</span> How does a phased array instrument steer the ultrasonic beam to a chosen angle?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> By mechanically rotating the element array inside the probe housing to the chosen angle</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> By delaying each element&apos;s pulse and signal so the wavefronts combine at that angle</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> By driving each element at a slightly different frequency across the array</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> By changing the couplant thickness under the wedge</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. By delaying each element&apos;s pulse and signal so the wavefronts combine at that angle</p><p style=\"margin:6px 0;\">Steering and focusing come from constructive interference: the instrument delays each element&apos;s pulse, and its received signal, according to a focal law. Frequency and couplant are not the steering mechanism.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT principle</p></details></div><div class=\"ptq-question\" id=\"paut2-02\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 2.</span> In phased array testing, what is a focal law?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> The code clause that sets the acceptance criteria for phased array indications</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> The maximum steering angle printed on the probe label for that wedge and frequency</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> The rule that the near field of each element equals D&#xB2;&#xB7;f/(4v)</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The active elements and delays used to form one beam at a given angle and focus</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. The active elements and delays used to form one beam at a given angle and focus</p><p style=\"margin:6px 0;\">Each beam in a sectorial or linear scan is produced by its own focal law. The instrument calculates the laws from the probe, wedge and material data entered by the operator, which is why those inputs must be correct.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT principle</p></details></div><div class=\"ptq-question\" id=\"paut2-03\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 3.</span> Which condition helps keep grating lobes low in a phased array probe?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> A pitch small relative to the wavelength, with steering kept within the design range</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> An element pitch several times larger than the ultrasonic wavelength in the test material</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Raising the frequency while keeping the same element pitch and aperture</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Using the largest steering angles the instrument and wedge allow</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. A pitch small relative to the wavelength, with steering kept within the design range</p><p style=\"margin:6px 0;\">Grating lobes appear when the pitch is large relative to the wavelength and grow at large steering angles. Raising the frequency shortens the wavelength, which makes the same pitch relatively larger and worsens grating lobes.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT principle (grating lobes)</p></details></div><div class=\"ptq-question\" id=\"paut2-04\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 4.</span> At a fixed frequency, what is the general effect of increasing the active aperture (using more elements per focal law)?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> The near field becomes shorter and the beam spreads more beyond it</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Deeper focusing becomes possible, with a narrower beam at the focus</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Sensitivity always decreases because the pulse is spread over more elements</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The beam can no longer be steered</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. Deeper focusing becomes possible, with a narrower beam at the focus</p><p style=\"margin:6px 0;\">A larger aperture lengthens the near field, and focusing is only effective within the near field, so a larger aperture allows deeper focusing and a smaller focal spot. It also usually increases sensitivity.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT principle (aperture and focusing)</p></details></div><div class=\"ptq-question\" id=\"paut2-05\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 5.</span> What distinguishes a linear (electronic) scan from a sectorial scan?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> A linear scan sweeps one aperture through a range of angles; a sectorial scan steps it along the array</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> A linear scan can only be used at 0&#xB0;, while a sectorial scan needs a wedge</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> A linear scan steps the aperture along the array at one angle; a sectorial scan sweeps the angle</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> There is no difference; the terms are interchangeable</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. A linear scan steps the aperture along the array at one angle; a sectorial scan sweeps the angle</p><p style=\"margin:6px 0;\">In a linear scan the same focal law is stepped across the array, so the beam moves sideways at a constant angle, which can be 0&#xB0; or an angled beam on a wedge. In a sectorial scan the aperture stays fixed and the angle changes.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT principle (scan types)</p></details></div></section><section class=\"ptq-topic\" id=\"topic-set-up-and-calibration\" aria-label=\"Set-up and calibration\"><h2>Set-up and calibration</h2><div class=\"ptq-question\" id=\"paut2-06\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 6.</span> What does wedge delay calibration correct for in a sectorial scan?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> The time each focal law spends in the wedge, so zero depth is the part surface</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Attenuation in the test material, which grows at the higher refracted angles</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Differences in frequency and sensitivity between the elements of the array</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Electrical noise picked up in the probe cable and connector</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. The time each focal law spends in the wedge, so zero depth is the part surface</p><p style=\"margin:6px 0;\">Each angle travels a different path through the wedge. Wedge delay calibration, usually on a known radius or side-drilled hole, sets the time zero for every focal law so that depths and sound paths are correct across the sector.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT calibration practice</p></details></div><div class=\"ptq-question\" id=\"paut2-07\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 7.</span> What is the purpose of angle-corrected gain (ACG) in a sectorial scan?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> To make the back-wall echo the same screen height at every depth</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> To remove grating lobes from the higher steering angles</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> To correct the depth readout for curved or uneven scanning surfaces</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> To give the same reflector the same amplitude on every angle</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. To give the same reflector the same amplitude on every angle</p><p style=\"margin:6px 0;\">Without ACG the response from a given reflector varies with angle because of wedge path, transmission and beam effects. ACG, commonly set on a radius or side-drilled hole, equalizes the angles so amplitudes can be compared across the sector.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT calibration practice</p></details></div><div class=\"ptq-question\" id=\"paut2-08\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 8.</span> How does time-corrected gain (TCG) differ from a DAC curve?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> TCG is used only for straight beams, while a DAC is used only for angle beams</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> TCG adjusts gain with time so equal reflectors show equal height; a DAC keeps gain fixed and draws a curve</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> TCG is drawn on the screen as a falling curve, whereas a DAC is a horizontal line</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> TCG removes the need for a calibration block, whereas a DAC requires one</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. TCG adjusts gain with time so equal reflectors show equal height; a DAC keeps gain fixed and draws a curve</p><p style=\"margin:6px 0;\">Both are built from the same type of reference reflectors at different depths. With TCG the reference level becomes a constant screen height across the depth range, which suits color-coded S-scan and C-scan displays.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT calibration practice</p></details></div><div class=\"ptq-question\" id=\"paut2-09\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 9.</span> Why is encoded scanning important in PAUT weld examination?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> It increases the effective probe frequency during scanning</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> It removes the need for couplant on smooth surfaces</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> It ties every A-scan to its position on the weld for length sizing and later review</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> It lets the software accept or reject indications automatically against the code limits</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. It ties every A-scan to its position on the weld for length sizing and later review</p><p style=\"margin:6px 0;\">Encoding gives every data point a position, which is what makes C-scans, length sizing and independent re-analysis of the stored data possible. Evaluation is still done by the qualified analyst.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice; ASTM E2700</p></details></div><div class=\"ptq-question\" id=\"paut2-10\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 10.</span> An encoder is checked by moving the scanner along a measured 500 mm. The instrument displays 495 mm. What is the encoder error?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> 0.5%</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> 1.0%</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> 5.0%</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> 10%</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. 1.0%</p><p style=\"margin:6px 0;\">Error = (500 &#x2212; 495) &#xF7; 500 &#xD7; 100 = 1.0%. The procedure states the allowed tolerance; if it is exceeded, the encoder is recalibrated before scanning.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice (encoder calibration)</p></details></div><div class=\"ptq-question\" id=\"paut2-11\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 11.</span> A sectorial scan is set from 40&#xB0; to 70&#xB0; in 0.5&#xB0; steps. How many focal laws does it contain?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> 30</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> 31</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> 60</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> 61</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. 61</p><p style=\"margin:6px 0;\">(70 &#x2212; 40) &#xF7; 0.5 = 60 steps, and counting both end angles gives 60 + 1 = 61 focal laws. Forgetting the starting angle gives the common wrong answer of 60.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT set-up</p></details></div></section><section class=\"ptq-topic\" id=\"topic-scan-planning-and-coverage\" aria-label=\"Scan planning and coverage\"><h2>Scan planning and coverage</h2><div class=\"ptq-question\" id=\"paut2-12\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 12.</span> On a 25 mm plate, the 55&#xB0; beam of a sectorial scan shows a reflector at a sound path of 40 mm. Where is the reflector relative to the probe index point?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Depth about 22.9 mm, surface distance about 32.8 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Depth about 32.8 mm, surface distance about 22.9 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Depth about 27.1 mm, surface distance about 32.8 mm</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Depth 40.0 mm, directly below the index point</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. Depth about 22.9 mm, surface distance about 32.8 mm</p><p style=\"margin:6px 0;\">Depth = 40 &#xD7; cos 55&#xB0; &#x2248; 22.9 mm, which is less than the 25 mm thickness, so the reflector is on the first leg. Surface distance = 40 &#xD7; sin 55&#xB0; &#x2248; 32.8 mm. Option B swaps sine and cosine; option C would only apply on the second leg.</p><p style=\"margin:6px 0;color:#475569;\">Basis: Angle-beam geometry</p></details></div><div class=\"ptq-question\" id=\"paut2-13\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 13.</span> Why must the probe offset (distance from the probe index or wedge front to the weld centerline) be set correctly and recorded?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> It sets the probe frequency used by the focal laws</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> It is only needed for thickness measurement and has no effect on weld coverage</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> It determines the wedge velocity used in the focal-law calculation</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Weld coverage depends on it, and the software uses it to place indications</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. Weld coverage depends on it, and the software uses it to place indications</p><p style=\"margin:6px 0;\">The scan plan&apos;s coverage is only achieved at the planned offset, and the analysis overlay places indications using it. A wrong offset can leave part of the weld unexamined and mislocate indications.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice (scan plan)</p></details></div><div class=\"ptq-question\" id=\"paut2-14\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 14.</span> What is the main purpose of a PAUT scan plan with a beam-coverage (ray-trace) drawing?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> To show the probes, angles, focal depths and offsets cover the weld and heat-affected zone</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> To record the technician&apos;s training hours and the equipment serial numbers</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> To list the acceptance criteria that apply to each type of indication</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> To replace calibration on a reference block once the plan is approved</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. To show the probes, angles, focal depths and offsets cover the weld and heat-affected zone</p><p style=\"margin:6px 0;\">The scan plan demonstrates, before scanning, that the set-up will examine the required volume. It does not replace calibration, and the acceptance criteria come from the code or specification.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice; ASTM E2700</p></details></div><div class=\"ptq-question\" id=\"paut2-15\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 15.</span> Why are PAUT weld scans often performed from both sides of the weld?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> To double the amount of data stored for archiving and audit</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Because from one side, planar flaws on the far fusion face may be missed</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Because the encoder only counts distance in one direction along the weld</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Because grating lobes appear only on the side the probe faces</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. Because from one side, planar flaws on the far fusion face may be missed</p><p style=\"margin:6px 0;\">Planar flaws such as sidewall lack of fusion are best detected with the beam near perpendicular to their face. Scanning from both sides gives favorable incidence on both fusion faces.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice (coverage)</p></details></div><div class=\"ptq-question\" id=\"paut2-16\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 16.</span> A one-line (single-pass) encoded PAUT scan is run parallel to the weld at a fixed probe offset. What provides coverage across the weld cross-section?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Moving the probe toward and away from the weld during the scan</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Raising the gain at the end of the scan</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> The range of angles (or apertures) swept electronically by the focal laws</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The encoder resolution</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. The range of angles (or apertures) swept electronically by the focal laws</p><p style=\"margin:6px 0;\">In a one-line scan the probe moves only along the weld; the electronic sweep of the sectorial or linear scan covers the cross-section. This is why the scan plan must confirm that the angle range and offset reach the whole volume.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice (one-line scanning)</p></details></div></section><section class=\"ptq-topic\" id=\"topic-data-analysis-and-sizing\" aria-label=\"Data analysis and sizing\"><h2>Data analysis and sizing</h2><div class=\"ptq-question\" id=\"paut2-17\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 17.</span> What should be checked first when reviewing a recorded PAUT data file, before evaluating indications?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Data quality: coupling, missing lines, encoder distance and saturation</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Whether the file name and folder follow the client&apos;s naming convention</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> The color palette and display layout chosen for the analysis views</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The number of indications already marked by another analyst</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. Data quality: coupling, missing lines, encoder distance and saturation</p><p style=\"margin:6px 0;\">Indications cannot be evaluated reliably in data with coupling loss, dropped lines or encoder slip. Sections with poor data quality are rescanned before analysis.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice (data quality)</p></details></div><div class=\"ptq-question\" id=\"paut2-18\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 18.</span> Which PAUT display shows the weld cross-section (depth against distance from the probe) at one position along the scan?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> The C-scan (top view)</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> The A-scan alone</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> The encoder position plot</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The S-scan (sectorial view)</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. The S-scan (sectorial view)</p><p style=\"margin:6px 0;\">The S-scan shows all angles at one scan position, corrected for angle so the weld cross-section can be overlaid. The C-scan is a plan view of amplitude or depth over the scanned area.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice (data views)</p></details></div><div class=\"ptq-question\" id=\"paut2-19\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 19.</span> With encoded PAUT data, how is the length of a weld indication usually measured?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> From the number of focal laws in the sector that show the indication</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Along the scan axis, between end points defined by the procedure</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> From the peak height of the echo in the A-scan at the reference level</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> From the width of the colored indication in the S-scan</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. Along the scan axis, between end points defined by the procedure</p><p style=\"margin:6px 0;\">Length lies along the scan direction, so it is measured on the encoded axis. The procedure defines how the ends are found, for example a 6 dB drop from the peak.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT sizing practice</p></details></div><div class=\"ptq-question\" id=\"paut2-20\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 20.</span> For a planar flaw whose upper and lower tips can be resolved, which method generally gives the most reliable through-wall height with PAUT?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Comparing the flaw&apos;s peak amplitude with the TCG reference level on the best angle</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Measuring the indication length in the C-scan</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Taking the depth difference between the upper- and lower-tip diffraction signals</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Counting the color bands across the indication in the S-scan</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. Taking the depth difference between the upper- and lower-tip diffraction signals</p><p style=\"margin:6px 0;\">Tip signals give the positions of the flaw extremities directly. Amplitude depends on orientation and roughness as well as size, and length says nothing about height.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT sizing practice</p></details></div><div class=\"ptq-question\" id=\"paut2-21\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 21.</span> Why must the weld overlay in the analysis software use the correct thickness, bevel geometry and probe offset?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> So indications plot in their true place, separating geometric echoes from flaws</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> So that the instrument can raise the frequency</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> So that the data file can be compressed for archiving</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Because the overlay sets the acceptance criteria for each indication automatically</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. So indications plot in their true place, separating geometric echoes from flaws</p><p style=\"margin:6px 0;\">An accurate overlay lets the analyst see whether an indication lies on the root, cap, bevel or in the parent metal. A wrong overlay can make a root geometry echo look like a flaw, or the reverse.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice (analysis)</p></details></div><div class=\"ptq-question\" id=\"paut2-22\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 22.</span> A flaw signal in the recorded data is saturated (it exceeded the instrument&apos;s maximum displayable amplitude). What is the problem?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> The flaw length cannot be measured at all from the saturated data</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Its true peak is unknown, so amplitude evaluation is unreliable</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> The encoder position for that scan line is lost</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> The calculated flaw depth doubles on the affected focal laws</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. Its true peak is unknown, so amplitude evaluation is unreliable</p><p style=\"margin:6px 0;\">Once the signal is clipped, its real amplitude above the reference level cannot be read. The area is rescanned at lower gain, or recorded with enough amplitude range, as the procedure requires.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice (data quality)</p></details></div><div class=\"ptq-question\" id=\"paut2-23\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 23.</span> How does a lack of sidewall fusion typically appear in a sectorial scan?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> As many small spots scattered through the weld center, on all the angles</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Only on the 0&#xB0; focal law, below the weld cap</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> With the same response on every angle in the sector</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Along the bevel line, peaking on angles near normal to the fusion face</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. Along the bevel line, peaking on angles near normal to the fusion face</p><p style=\"margin:6px 0;\">Sidewall lack of fusion is planar and follows the bevel, so it plots on the fusion line and peaks on the angles that strike it squarely. Scattered small spots are more typical of porosity.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT interpretation</p></details></div></section><section class=\"ptq-topic\" id=\"topic-codes-procedures-and-documentation\" aria-label=\"Codes, procedures and documentation\"><h2>Codes, procedures and documentation</h2><div class=\"ptq-question\" id=\"paut2-24\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 24.</span> Which ASTM standard is a practice for contact ultrasonic testing of welds using phased arrays?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> ASTM E2700</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> ASTM E2373</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> ASTM E309</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> ASTM E1444</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: A. ASTM E2700</p><p style=\"margin:6px 0;\">ASTM E2700 covers contact PAUT of welds. ASTM E2373 covers TOFD, ASTM E309 covers eddy current examination of steel tubular products, and ASTM E1444 covers magnetic particle testing.</p><p style=\"margin:6px 0;color:#475569;\">Basis: ASTM E2700</p></details></div><div class=\"ptq-question\" id=\"paut2-25\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 25.</span> Which change would normally require the PAUT procedure or scan plan to be revised, and requalified where the code requires it?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> A different technician on the same shift who holds the same certification and level</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> A new batch of the same couplant from the same supplier</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Using a probe with a different element count, pitch or frequency, or another wedge</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Using a different method of post-examination cleaning</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. Using a probe with a different element count, pitch or frequency, or another wedge</p><p style=\"margin:6px 0;\">Probe, wedge and focal-law parameters change the beams produced and therefore the coverage and sensitivity, so codes treat them as essential variables. ASME Section V Article 4 lists such variables for UT procedures.</p><p style=\"margin:6px 0;color:#475569;\">Basis: ASME BPVC Section V, Article 4 (procedure requirements)</p></details></div><div class=\"ptq-question\" id=\"paut2-26\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 26.</span> A PAUT Level II finds that the wedge specified in the approved scan plan is not available on site. What is the appropriate action?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Use any available wedge with a similar nominal angle and simply note the change in the report</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Change the wedge velocity in the software until the S-scan image looks right</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Refer to the Level III; substitute only if the procedure or an approved revised plan allows</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Proceed without a wedge, scanning directly on the array face</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. Refer to the Level III; substitute only if the procedure or an approved revised plan allows</p><p style=\"margin:6px 0;\">A different wedge changes the focal laws and coverage. A Level II works within the approved procedure; changing an essential variable needs the procedure owner&apos;s revision and approval.</p><p style=\"margin:6px 0;color:#475569;\">Basis: ASNT SNT-TC-1A (Level II and Level III responsibilities)</p></details></div></section><section class=\"ptq-topic\" id=\"topic-method-limitations\" aria-label=\"Method limitations\"><h2>Method limitations</h2><div class=\"ptq-question\" id=\"paut2-27\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 27.</span> Which statement describes a genuine limitation of PAUT compared with manual single-element UT?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> PAUT cannot detect planar flaws such as lack of sidewall fusion</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> PAUT data cannot be recorded or reviewed after the scan</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> PAUT cannot be used on butt welds in carbon steel</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> An error in the probe, wedge or material data affects every calculated beam</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: D. An error in the probe, wedge or material data affects every calculated beam</p><p style=\"margin:6px 0;\">Every beam is calculated from operator inputs, so an error in probe, wedge, velocity or offset data affects all the results, which is why set-up and calibration demand more training and verification. PAUT detects planar flaws such as sidewall lack of fusion, records data for later review and is widely used on carbon steel butt welds.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT principle</p></details></div><div class=\"ptq-question\" id=\"paut2-28\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 28.</span> Why is the usable angular range of a sectorial scan limited, especially far from the wedge&apos;s nominal refracted angle?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> Because the encoder cannot record data from angles away from the nominal angle</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Because the probe frequency changes as the steering angle increases</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Because amplitude falls and grating or side lobes grow as the beam is steered further</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Because the couplant layer becomes thicker at the higher steering angles</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. Because amplitude falls and grating or side lobes grow as the beam is steered further</p><p style=\"margin:6px 0;\">Steering efficiency drops with steering angle, and ACG can raise amplitude but not remove lobes or restore beam shape. The scan plan should use angles within the range the probe and wedge handle well.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT principle (beam steering limits)</p></details></div><div class=\"ptq-question\" id=\"paut2-29\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 29.</span> For coarse-grained austenitic or dissimilar-metal welds, which PAUT configuration is commonly chosen to reduce scatter and noise?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> High-frequency shear-wave linear arrays with fine element pitch</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Dual (transmit-receive) arrays using low-frequency refracted longitudinal waves</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> A single large shear-wave array at the highest frequency the instrument supports</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> Surface-wave arrays placed on each side of the weld cap</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: B. Dual (transmit-receive) arrays using low-frequency refracted longitudinal waves</p><p style=\"margin:6px 0;\">Longitudinal waves at lower frequency are less affected by coarse, anisotropic grain structures, and separate transmit and receive arrays reduce wedge noise. High-frequency shear waves scatter more in these materials.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice (austenitic welds)</p></details></div><div class=\"ptq-question\" id=\"paut2-30\" style=\"margin:0 0 22px;padding:14px 16px;border:1px solid #d7e1ea;border-radius:8px;\"><p class=\"ptq-stem\" style=\"margin:0 0 8px;font-weight:600;\"><span class=\"ptq-num\" style=\"color:#075fa8;\">Question 30.</span> When a small-diameter pipe circumferential weld is examined with a flat-bottomed wedge, what is the main risk?</p><ol class=\"ptq-options\" type=\"A\" style=\"list-style:none;padding-left:0;margin:0 0 8px;\"><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">A.</span> An increase in the effective probe frequency caused by the curved surface</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">B.</span> Loss of encoder counts, with no effect on the beam itself</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">C.</span> Poor coupling and beam distortion, so a contoured wedge is normally used</li><li style=\"margin:2px 0;\"><span style=\"display:inline-block;min-width:1.6em;font-weight:600;\">D.</span> An automatic change from a sectorial scan to a linear scan</li></ol><details class=\"ptq-answer\" style=\"margin:6px 0 0;\"><summary style=\"cursor:pointer;color:#075fa8;font-weight:600;\">Show answer</summary><p style=\"margin:6px 0;\">Correct answer: C. Poor coupling and beam distortion, so a contoured wedge is normally used</p><p style=\"margin:6px 0;\">A flat wedge rocks on a curved surface, giving a thick, uneven couplant layer and an altered beam entry. Wedges contoured to the curvature keep coupling and beam geometry consistent.</p><p style=\"margin:6px 0;color:#475569;\">Basis: General PAUT practice (curved surfaces)</p></details></div></section>\n<section data-course-next-step=\"2026-10\" data-placement=\"end\" aria-label=\"Course next step\" style=\"border-left:4px solid #2563eb;padding:10px 0 10px 16px;margin:24px 0;\"><h2 style=\"font-size:1.25rem;font-weight:700;line-height:1.3;margin:0 0 8px;\">Next step: PAUT Level 2 course</h2><p style=\"margin:0 0 8px;\">Practice questions check recall. Structured training adds the classroom and hands-on hours your certification route requires. The <a href=\"/paut-level-2-training-course\" style=\"color:#2563eb;text-decoration:underline;\">PAUT Level 2 course</a> covers probe and wedge selection, focal-law set-up, sectorial and encoded scanning, and scan-plan execution. Completing a course is not certification: under an employer-based scheme such as SNT-TC-1A, your employer certifies you after its own examinations.</p><p style=\"margin:0 0 8px;\"><strong>For employers:</strong> <a href=\"/consulting/ndt-consulting-level-iii\" style=\"color:#2563eb;text-decoration:underline;\">ASNT Level III consulting</a> covers procedures, the written practice, qualification examinations and audit support for your technicians.</p></section>\n<section data-practice-next=\"2026-10\" aria-label=\"Where to go next\" style=\"border-left:4px solid #2563eb;padding:10px 0 10px 16px;margin:24px 0;\"><h2>Where to go next</h2><p>Atlantis NDT courses run year-round, with theory online and hands-on practice on the Practical NDT simulator or in person at the client&apos;s own facility. From here:</p><ul><li><a href=\"/ultrasonic-testing-training\">Ultrasonic testing (UT) training</a>: what Level I and Level II mean in the method and what the practical examination tests. Phased array is an ultrasonic technique, so it sits inside the ultrasonic method body of knowledge.</li><li><a href=\"/tools/ultrasonic-a-scan-simulator\">Ultrasonic A-scan simulator</a>: rehearse range, gain and gate settings on a simulated flaw detector in the browser.</li><li><a href=\"/ndt-practice-tests\">All NDT practice tests</a>: Level II sets for UT, PAUT, TOFD, RT, MT, PT, VT and ET, with exam preparation guides.</li><li><a href=\"/asnt-ndt-level-ii-exam-prep\">ASNT NDT Level II exam preparation</a>: if you are sitting ASNT&apos;s central Level II examination.</li><li><a href=\"/asnt-level-iii-ut-exam-prep\">ASNT Level III UT exam preparation</a>: the route once Level II work and experience are behind you.</li></ul><p><a href=\"/contact?service=training&amp;subject=PAUT%20Level%20II%20training\">Enquire about PAUT Level II training</a> for yourself or for a team. Tell us the method, the level and where the trainees are based.</p></section>","order":0,"createdAt":"2026-06-24","updatedAt":"2026-10-16T00:00:00Z","h1":"Phased Array UT (PAUT) Level II Practice Questions"}